There is no price at present, you can Request a Quote
Used for diverting or mixing process media.
One 3-way valve can replace several other valves plus the ssociated piping pieces.
Antistatic device.
Blowout-proof stem.
Double “D” stem head.
igh performanceHYPATITE®PTFE ball seats.
Actuator mounting pad to KITZ standard.
Page 100 for Pressure-Temperature Ratings.
T-port, 4-seated.
Valve operator:NPS ½ to 8 :Lever operation.
NPS 5 to 8 :Optional gear operation.
Note:10K type is also available.
Nominal Size:DN:15
NPS:1/2
Ball bore:15
L:120
L1:61
H:128
D:160
KITZ Ball Valve 150UTB4TA/M DN15
There is no price at present, you can Request a Quote
People who bought this item also viewed
ROTEN Mechanical Seal 8E5K-22-X
Rockwell Allen-Bradley AB VFD 20BD125A3ANNANC0
CAHO Temperature Controller P961KIO2-1
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Chint Relay JD102S 12V
Sumitomo Gear Pump NB4-G63F
Recent related posts
-
07/19/2020
The principle structure, advantages and disadvantages of scroll refrigeration compressor
Principle: The scroll line pattern of the moving plate and the static plate are the same, but the phase difference is 180°C; they mesh to form a series of closed spaces; the static plate does not move, and the moving plate revolves around the center of the fixed plate with the eccentricity as the radius. When the moving disc revolves, it meshes in sequence, so that the crescent-shaped area is continuously compressed and reduced, so that the gas is continuously compressed and finally discharged from the center hole of the static disc
-
01/03/2021
Danfoss Thermostats
Cold Controls (thermostats) are subject to the LVD directives, meaning they must be tested according to this Directive so that customers can feel safe and secure during buying and installing these Cold Controls. Danfoss Cold Controls also called 077B to h 器2 䀀 ᅵ皥 䖒皦즠Ʋ㉄ᰙ 㲈Ʋ 䌁皦 ᮔDž༬皧㉎ᰙЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿먲僧ᐱ㥲ᐲ�僬㣢ᐲ ᠾ 랖僧բ 識 �僬㣢ᐲ 臆S㥲ᐲ ᬄğ 識 理艏S杴 識杴 㥲ᐲ
-
07/19/2020
Types of refrigeration compressors for industrial chillers
The energy efficiency ratio of the chiller compressor of the chiller unit determines the energy efficiency ratio of the entire refrigeration system. Since the ambient temperature changes, the compressor is in a partial load state most of the time, so the compressor must have energy regulation.
-
06/21/2020
Common faults and maintenance of air compressor
Common faults and maintenance of air compressor <img src="{{media url="Common_faults_and_maintenance_of_air_compressor.jpg"}}" alt="" /> Common faults and maintenance of air compressor Air compressors are widely used in various industries with the development of technology, but no matter what type of air compressor, there will be some problems in the process of use. The following editors will now introduce some common faults and maintenance methods, let's take a look.
-
07/19/2020
Advantages and disadvantages of screw refrigeration compressors
Screw refrigeration compressor is a rotary positive displacement compressor. It uses the change of the cogging volume and position of the screw to complete the process of vapor suction, compression and exhaust. Oil-free screw compressors came out in the 1930s, mainly used to compress air. Later, the oil-injected screw compressor appeared in the cylinder,
-
06/14/2020
Air conditioning expansion valve
What is the principle of air conditioning expansion valve? The electronic expansion valve is a throttling element that can enter the refrigerant flow of the refrigeration device according to a preset procedure
-
07/19/2020
The role of precision chillers in various industries
In the precision chiller, the heat absorbed from the evaporator and refrigeration compressor and in the pipeline is transferred to the surrounding medium to take away, and the refrigerant high-pressure superheated vapor recondenses into a liquid. In the cooling process of the chiller, the condenser plays a role in outputting heat energy and condensing the refrigeran
-
07/13/2020
Danfoss H series high temperature air conditioning compressor
compressor trading platform Self-operated inventory, lightning delivery within 7 days! okmarts.com has more than 70,000 square meters of warehouse, using modern small warehouse management technology, all goods are sold in stock, lightning delivery within 7 days.
-
08/19/2020
How to choose the correct cold storage condenser
The condenser is one of the main heat exchange equipment in the cold storage refrigeration system, and its function is to cool and condense the high-temperature refrigerant superheated
-
07/19/2020
Basic knowledge of refrigeration compressor
After shutting down, stop for at least 3 minutes before starting again to eliminate the pressure difference between the compressor inlet and outlet. Because in the case of a large pressure difference, the starting torque of the motor will increase, causing the current to rise to a certain level, the protector will act and the compressor cannot continue to run.