Full flow rate(ton/h):600
Head(m):29
Power:3750W
KMP Water Pump EMP-545
People who bought this item also viewed
WALRUS Water Pump TPK4T8-8
PROCON Water Pump 113S100F31GC095
MINAMOTO Water Pump YLGB50-18
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
EACO Capacitor STD-1200-0.22-32
Honeywell Bar Code Scanner 1900HHD Wire
Shimadzu Gear Pump SGP1A34F2H5-L
Yaskawa Servo Motor SGMAS-02ACA4E
Recent related posts
-
08/20/2020
Taboos for installing air conditioning and refrigeration pipes
Air-conditioning refrigeration pipes are used as auxiliary equipment in air-conditioning installation, but their importance cannot be ignored. If all relevant components have been
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
09/14/2020
What is an air compressor
The machine used to generate compressed air is also called compressed air machine, also called air compressor, or air compressor for short. The motor directly drives the compressor to make the crankshaft produce rotational movement, drive the connecting rod to make the piston produce reciprocating motion, and cause the cylinder volume Variety.
-
09/11/2020
Hanbell screw compressor oil replacement operation specification
Maintenance and operation instructions for the refrigerating oil of the screw refrigerant compressor of Hanbell 1. The role of lubricating oil:
-
04/25/2023
What are the 4 Main Components in a Central AC System
There are four main components in the central air conditioning system, namely: compressor, condenser, throttling device, and evaporator. Evaporators and condensers are collectively referred to as heat exchangers
-
01/07/2021
The method to identify the failure of the totally enclosed refrigeration compressor is very effective!
The method to identify the failure of the totally enclosed refrigeration compressor is very effective! 1. How to identify the three binding posts on the casing of the hermetic compressor? Running end (R), starting end (S), common end (C), the re 器2 䀀 ᅵ皥 䖒皦즠Ʋ奌ི 㲈Ʋ 䌁皦 ᮔDž༬皧奖ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱
-
11/23/2021
Different Types of Pressure Transmitters
Pressure transmitter is a kind of instrument which can convert pressure variable into standard output signal. There is a functional relationship between the pressure variable and the output signal of pressure transmitter.
-
08/03/2020
Causes, harm, treatment and prevention methods of refrigeration compressor liquid strike
Liquid hammer refers to the situation in which the refrigerant liquid or wet vapor is sucked into the compressor by the compressor due to the failure or insufficient heat absorption and evaporation of the refrigerant, which is called liquid hammer.<br></bﰨ2 䀀
-
01/10/2021
India Compressor Market Analysis and Growth Forecast till 2024
By pnsintelligence India compressor market is expected to reach $2.7 billion by 2024, registering a CAGR of 7.0% during 2019-2024. The market is buoyed by several factors, primarily substantial demand coming from the automotive sector supported by risi 器2 䀀 ᅵ皥 䖒皦즠Ʋ奌ི 㲈Ʋ 䌁皦 ᮔDž༬皧奖ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب
-
09/06/2020
How to choose an air compressor in the food industry
Compared with other production-oriented industries, food safety is more important in the food industry. When choosing an air compressor, choose oil-free air compressors, which are also screw type, in order to ensure product quality.