KOGANEI Air Cylinder ORGA25X1300
People who bought this item also viewed
KOGANEI Air Cylinder ARSZ10X10
KOGANEI Air Cylinder CDA25X10
KOGANEI Air Cylinder DAB16X25-2
KOGANEI Air Cylinder CDA25X30-B
Festo Air Cylinder DSNU-12-10-P-A
Festo Air Cylinder DNC-40-20-PPV-A
AirTAC Air Cylinder MD10X10
HENGSTLER Encoder RI58-T/2048AK.42RH
Ingersoll Rand Solenoid Valve 22130439
Belimo Actuator LM230A-S
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Beckhoff Module CX1010-N000
SONGCHUAN Relay 841S-2A-C1-12VDC
Festo Air Cylinder DSBC-80-60-D3-PPVA-N3
COSEL Power Supply PBA50F-5-V
UNID Solenoid Valve UD-15
Recent related posts
-
08/11/2020
How much do you know about the application analysis of evaporators
As one of the four major components of refrigeration, the evaporator plays a vital role in the entire refrigeration system. Therefore, the compressor and evaporator can only be matched reasonably to make the entire refrigeration system play a better effect.
-
07/19/2020
Types of refrigeration compressors for industrial chillers
The energy efficiency ratio of the chiller compressor of the chiller unit determines the energy efficiency ratio of the entire refrigeration system. Since the ambient temperature changes, the compressor is in a partial load state most of the time, so the compressor must have energy regulation.
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
06/14/2020
Solar driven adsorption refrigeration
Solar driven adsorption refrigeration Shanghai Jiaotong University Wang Ruzhu and other nearly 20 years of painstaking research "adsorption refrigeration adsorption mechanism, cycle construction and thermal design theory" won the second prize of the 2014 ﰸ2 䀀 ᅵ皥 䖒皦즠Ʋ
-
06/21/2022
What is a Transformer?
A transformer is a passive component that transfers electrical energy from one electrical circuit to another circuit, or multiple circuits.
-
06/29/2020
Compression ratio of American Copeland compressor
-
07/04/2020
How COVID-19 impact on the Air Compressor Market?
COVID-19 (Coronavirus) has resulted in many advantages and disadvantages for companies in the Oil Free Compressor market. Research report of this Oil Free Compressor market is highlights key strategies that can help reduce the impact of COVID-19 on diverse business practices.
-
06/14/2020
Causes of liquid shock in refrigeration compressors
Causes of liquid shock in refrigeration compressors 1) Too much refrigerant is added to the entire refrigeration system. 2) The throttle valve is opened too large, or the adjustment is malfunctioning. 3) The evaporation area is too sm 器2 䀀 ᅵ皥 䖒皦즠Ʋ煔क़ 㲈Ʋ 䌁皦 ᮔDž༬皧煞क़Ѐ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿먲僧ᐱ㥲ᐲ�僬㣢ᐲ ᠾ 랖僧ք 識 �僬㣢ᐲ 臆S㥲ᐲ ᬄğ 識 理艏S杴 識杴 㥲ᐲ
-
11/11/2021
Different Types of Pressure Transmitters, Working Principle, and How to Select Pressure Transmitter
Pressure transmitter is a kind of pressure measuring instrument widely used in many transmitters. It is widely used in petroleum, chemical, metallurgy, food, electric power, medicine, papermaking, textile and other industries.
-
08/11/2020
How to maintain the lubrication system of the chiller
In the operation system of the chiller, more attention is paid to the refrigerant circulation system, the chilled water circulation system and the electrical control system of the refrigerator. The lubrication system is often overlooked. As everyone knows, this system is also very important to the chiller.