Output Voltage("H"):[(Supply Voltage) -3 V] or more
Output Voltage("L"):0.4 V or lower
Load Supply Voltage:30 V DC or lower
Output Current(Inflow):Up to 30 mA
Output Current(outflow):Up to 10 mA
Maximum Response Frequency:200 kHz
KOYO Hollow-shaft Incremental Rotary Encoder TRD-2TH1000AF
People who bought this item also viewed
KOYO Encoder TRD-RV1024-4PR-T
Renishaw Encoder TI0200A25A
HENGSTLER Encoder AC58/1212ES.41SGD
Lika Encoder IT65-H-2000ZCU4ER
Renishaw Encoder RGH22B05L00A
Yaskawa Servo Motor SGMG-13ASACB
Panasonic Servo Drive MSD023A1X
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Mitsubishi HMI GT1030-HWDW
Rockwell A-B HMI 2711P-B15C6A2
KEMET Capacitor 50VDC 10UF
Furnan Vane Pump VHO-F-20-A3
Recent related posts
-
03/07/2021
AC servo driver wiring precautions
For signal line and encoder input line, please use shielded wire. Wiring length: the length of signal line from NC to AC servo driver is less than 3m, and the length of input line from AC driver to encoder is less than 20m. The ground wire should be thick wire as far as possible. According to the third grounding standard (grounding resistance < 100 Ω), one point grounding method should be adopted to connect the ground wire. If the motor and the machine tool are insulated, the motor should be grounded.
-
06/14/2020
The principle of air heat pump heating
In our lives, we often say "warm and warm to the house" to our guests. Compared with the cold and wet climate in the southern region, the cold in the northern region is dry and cold. The outdoor working temperature is minus ten or twenty degrees, which is 器2 䀀 ᅵ皥 䖒皦즠Ʋ焬क़ 㲈Ʋ 䌁皦 ᮔDž༬皧然क़Ѐ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់
-
07/03/2020
Global Piston Compressor Market Insight Report 2020 – Ariel, Siemens, Atlas Copco, Kobelco, Burckhardt Compression, Ingersoll Rand
Reports Insights Portable Oil Free Air Compressor Market Overview 2020 – 2026 The rising technology in Portable Oil Free Air Compressor Market is also depicted in this research report. Factors that are boosting the growth of the market, and giving a positive push to thrive in the global market is explained in detail.
-
04/13/2023
15 Refrigeration System Components Structure, Function, Working Principle Diagram (1)
There are four main components in the refrigeration system, namely compressor, condenser, throttling device (such as capillary tube, expansion valve), evaporator.
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
03/02/2021
Connection between Arduino and servo motor
The connection of the servo motor using Arduino is as follows: Connect the black wires on the two servo motors to the GND on the Arduino Connect the red wires on the two servo motors to the 5V pin on the Arduino Connect the yellow wire on the first motor to pin 8 on the Arduino
-
07/22/2020
The ranking of compressor industry companies has changed so much
Due to the high technical threshold and high capital investment of the compressor industry, the concentration of the top five brands of the five major compressors in the industry has exceeded 63%, but the five major products also reflect different differentiation and evolution trends.<br></br>
-
05/08/2023
Functions and Types of Condensers in Refrigeration System
Condenser, a component of the refrigeration system, is a type of heat exchanger that can convert gas or vapor into liquid, and transfer the heat in the tube to the surrounding air in a very fast speed.
-
08/20/2020
Precautions on how to prevent freezing in winter chillers
As the temperature drops, winter is approaching. Last year, many customers’chillers experienced freezing failures. The editor of okmarts.com reminds everyone to do a good job of antifreeze work.
-
12/29/2023
How to Maintain the Solar Inverter Cooling Fan in Hot Weather?
Solar inverters are generally installed outdoors and are affected by natural factors such as sun, rain, sand, dust or high temperature.