KYOCERA Tool for Metal Cutting TPGH110304L PR930
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
NKK Switch WT-28AL
Recent related posts
-
08/07/2020
Common physical and chemical methods for removing scale in condensers in chillers
The water chiller is prone to scale formation in the condenser pipe after long-term use. If it is not treated in time, these scales will affect the heat exchange effect and cause the condensing temperature of the unit to increase
-
08/24/2020
Why does the cooler temperature drop slowly
1. The cold storage has a large loss of cold due to poor heat insulation or sealing performance. Poor thermal insulation performance is due to insufficient insulation thickness of pipes, warehouse insulation walls, etc.,
-
12/23/2021
Five Pros of Refrigeration Compressor of Mitsubishi Electric
For refrigeration products, high efficiency and energy saving are the constant pursuit and breakthrough of technology.
-
08/17/2020
The heat pump is prone to frost between +4~-4℃. The symptoms and reasons are not beyond these 10 points.
The air source heat pump can use the low-grade heat energy in the ambient air, so it has the dual advantages of energy saving and environmental protection. However, one of the problems is that
-
07/01/2020
Why does the centrifugal Taikang compressor have such a high speed
Why does the centrifugal Taikang compressor have such a high speed Centrifugal compressors require speed during operation, and the speed is very high. However, many people do not understand, why does a centrifugal compressor need such a large speed? Let us take a centrifugal Taikang compressor as an example to explain this problem for everyone.
-
07/23/2020
Analysis of Overheating Failure of Refrigeration Compressor
The main reasons for the overheating of exhaust temperature are as follows: high return air temperature, large heating capacity of the motor, high compression ratio, high condensation pressure, and improper refrigerant selection.<br></br> <br></br>
-
08/17/2020
Drainage method of refrigeration pipe during cold storage installation
Before the cold storage is installed, the refrigeration pipe must be thoroughly removed. The rust and dirt on the inner and outer walls of the pipe must be removed, and the inner wall must be kept dry.
-
06/14/2020
After continuous decline, how can scroll compressors play new tricks
After continuous decline, how can scroll compressors play new tricks With the market share being seized by the rotor compressor and the "disease and external troubles" of the macroeconomic downturn
-
07/13/2020
Identify the authenticity of Danfoss compressors solenoid valves expansion valves and filters
HVAC】Innovative products and series of Danfoss commercial compressors To date, Danfoss has provided more than 100,000 air-conditioning large scroll compressors to the Chinese air-conditioning market.
-
08/03/2020
What is the cooling system of the computer room refrigeration facility, adsorption refrigeration, and assembly cold storage
Many people have little understanding of the cooling system of the computer room refrigeration facility, adsorption refrigeration, and prefabricated cold storage.