Recent related posts
-
08/24/2020
What kind of equipment is suitable for high and low pressure refrigerant charging method
There are generally two types of refrigerant charging methods: low-pressure charging and high-pressure charging. The advantage of the low pressure charging method is that it is easier to control the amount of refrigerant charged,
-
11/30/2023
A Complete Guide to CPU Liquid Coolers: Composition, Working Principle, Types, and Pros and Cons
With increasing requirements for computer hardware and operating speed, there are higher and higher requirements for the cooling performance of computers.
-
05/05/2023
What is Vapour Compression Refrigeration System?
Vapour compression refrigeration system (VCRS) is the most common cooling system used in modern refrigeration technology.
-
06/13/2020
Cause Analysis of Refrigeration Compressor Cannot Start or Stop Quickly After Start
Cause Analysis of Refrigeration Compressor Cannot Start or Stop Quickly After Start 1) First check the main circuit. Whether the power supply has power, whether the voltage is normal, whether the fuse has been blown due to starting overload
-
07/25/2020
The 9 types of compressor failure and hazard analysis are all in it! ! !
Start with liquid is a problem that easily occurs during shutdown. In the shutdown state, the refrigerant will migrate from the system back to the compressor and be deposited in the lubricating oil.
-
06/29/2022
Installation of Axial Piston Pump
The installation quality of axial piston pump is very important. If it is not installed properly, it will have a direct impact on the service life and even be damaged soon.
-
06/19/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
01/11/2021
[Case] Air conditioner compressor does not work after Mitsubishi Pajero overhaul Failure phenomenon:
[Case] Air conditioner compressor does not work after Mitsubishi Pajero overhaul Failure phenomenon: The Mitsubishi Pajero off-road vehicle uses a 6G72 engine. The air-conditioning compressor does not work after the car is overhauled and the condenser 器2 䀀 ᅵ皥 䖒皦즠Ʋ奌ི 㲈Ʋ 䌁
-
09/15/2021
6 Reasons for Refrigeration Compressor Not to Start
When speaking of air conditioners, everyone is familiar with them. Especially in the hot summer, we would not know how to live without it.
-
09/20/2020
Noise life
For household appliances bearings, the bearing load is very small and the bearing life is very long. However, after a certain period of operation, the bearing will also cause wear, increased vibration and noise, and deterioration of grease.