Product type | Rotary Compressor |
Series | QPT Series |
Size | Φ139 |
Refrigerant | R22 |
Specification | Twin |
Displacement | 52.5 cc/rev |
Phase | 1 PH |
Rated voltage | 220/240 V |
Frequency | 50 Hz |
Motor type | Concentrated |
Cooling Capacity (Btu/hr) | 31,100 |
Cooling Capacity (Watts) | 9,114 |
Input (Watts) | 2,880 |
EER (Btu/W·hr) | 10.80 |
COP (W/W) | 3.16 |
Test condition | ARI |
Magnet | - |
Condensing temperature | 54.4°C |
Evaporating temperature | 7.2°C |
Suction temperature | 18.3°C |
Sub cool | 8.3°C |
LG Compressor QPT525PBA
People who bought this item also viewed
Bristol Compressor H79B35UABHA
Tecumseh Compressor RKA5512YXA
Tecumseh Compressor RK5480Y
LG Compressor GA086CDA
LG Compressor GKS110CAC
LG Compressor MA53LBCM
LG Compressor QJ208HMA
TRANE Compressor CSHA150K
GMCC Compressor PH441X3CS-4MU1
Danfoss Compressor 104H7270
Danfoss Compressor MTZ125HU4VE
CHINT Transformer JBK3-630
Castel Expansion Valve 2028/M10S02
TENGEN Contactor CJX1-205/22
Nidec Fan D06X-12TS4
Oriental Motor Electric Motor PK569AE
LEEMIN Filter SFX-1300-3
Danfoss Sight Glass SGN22N
SIEMENS Capacitor B43584-S6608-Q2
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
SUNON Fan KD0506PHB3
REXROTH Overflow Valve DBDS10G10B/25
AirTAC Air Cylinder MCKA63X200
Keyence Sensor PT-A160SO(1204)
Recent related posts
-
07/23/2020
Do you know the causes, hazards, treatment and prevention methods of compressor liquid strike?
Liquid hammer refers to the situation in which the refrigerant liquid or wet vapor is sucked into the compressor by the compressor due to the failure or insufficient heat absorption and evaporation of the refrigerant, which is called liquid hammer.<br></br> <br></br>
-
03/13/2021
Working mode of servo driver
The working modes of servo driver are: open loop mode, voltage mode, current mode (torque mode), IR compensation mode, Hall speed mode, encoder speed mode, tachometer mode, and analog position loop mode (ANP mode). (not all of the above modes exist in all models of drives)
-
07/07/2020
Why defrost cold storage What are the ways to defrost
Why defrost cold storage What are the ways to defrost I. Overview: The frost on the surface of the evaporator in the cold storage hinders the conduction and distribution of the cooling capacity of the refrigeration evaporator (pipe), which ultimately affects the cooling effect.
-
08/19/2020
How to solve the drainage problem of window air conditioner
Although window air conditioners are not common in life, some consumers still use them. We should also have some understanding of window air conditioners. Compared with split air conditioners
-
08/20/2020
Taboos for installing air conditioning and refrigeration pipes
Air-conditioning refrigeration pipes are used as auxiliary equipment in air-conditioning installation, but their importance cannot be ignored. If all relevant components have been
-
06/15/2020
Danfoss expands portfolio of oil-free compressors with new TGS490
Danfoss expands portfolio of oil-free compressors with new TGS490 Danfoss, the world’s leading manufacturer of oil-free compressor technology, has expanded the oil free compressor portfolio with the introduction of the TGS490.
-
11/12/2023
9 Types of Fan Bearing Comparison: How to Have Both Quietness and Longevity?
Quietness and longevity have always been two very important performance parameters in the PC heat dissipation field, and the fan can be said to be the biggest source of noise inside the entire computer case.
-
06/19/2020
Installation instructions for explosion-proof air conditioners
Installation instructions for explosion-proof air conditioners <img src="{{media url="Installation_instructions_for_explosion-proof_air_conditioners.jpg"}}" alt="" /> 1. The power supply of the explosion-proof air conditioner shall have a dedicated line, and a circuit breaker or air switch shall be provided in the dedicated line. The power supply wires and fuses should comply with the relevant regulations and cannot be changed at will.
-
09/11/2020
Recent market development of air source heat pumps in various countries in the world
The 1997 World Climate Summit in Kyoto, Japan established the reduction of greenhouse gases (GHG), achieving the goal of reducing greenhouse gases by at least 5% below 1990 levels between 2008 and 2012.
-
06/13/2020
Detailed process of refrigeration compressor replacement
Detailed process of refrigeration compressor replacement After confirming that there is only a problem with the compressor and it needs to be replaced, proceed to prepare for the replacement of the compressor. Specific steps are as follows: