Littelfuse Fuse FLM3/10
People who bought this item also viewed
Schneider Contactor LC1D80008Q7
Honeywell Relay SZR-MY2-N1-AC24V
UniOhm Resistor 0805W8J0753T5E
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Schneider Sensor XS8G12MB230
FOTEK Sensor MR-60X
JANUS Vane Pump VP-08-FA1Y
LIMING Electric Motor CM07IG15SBB
UNIVER Solenoid Valve AM-5021
Recent related posts
-
04/01/2022
How to Replace Air Conditioner Fan Blade?
Air conditioner is also known as air conditioning machine. It is a machine that manually adjusts and controls the temperature, humidity, cleanliness, speed and other parameters of the ambient air in the building.
-
08/11/2020
Types of refrigerants and leak detection methods
Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south. It is a working substance that continuously circulates in the refrigeration system and realizes refrigeration through its own state changes.
-
09/15/2020
Reasons and necessity of overhaul of oil-injected twin-screw air compressor
The structure of the main engine (also known as the head) of an oil-injected twin-screw air compressor is usually composed of a pair of mutually meshing screws, main engine casing, high-pressure end and end cover, and low-pressure end and end cover.
-
08/02/2020
New refrigerant R450A is used for performance study of ejector refrigeration cycle
The new refrigerant R450A is a substitute for R134a, which is environmentally friendly and reliable. There are still few studies on it.
-
06/19/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
09/06/2022
What is the Difference between Synchronous and Induction Motor
Electric motors are roughly divided into three types, synchronous motor, asynchronous motor
-
06/13/2020
How to configure the cold storage refrigeration equipment
How to configure the cold storage refrigeration equipment How to configure the cold storage refrigeration equipment? As a total solution provider for cold storage, Sike Refrigeration has rich experience in the installation of cold storage refrigeration e 器2 䀀 ᅵ皥 䖒皦즠Ʋ煔क़ 㲈Ʋ 䌁皦 ᮔDž༬皧煞क़Ѐ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ
-
06/21/2020
Causes and judgement of centrifugal compressor surge
Causes and judgement of centrifugal compressor surge Causes of centrifugal compressor surge ①Flow<img src="{{media url="Causes_and_judgement_of_centrifugal_compressor_surge.jpg"}}" alt="" /> Each centrifugal compressor corresponds to a curve between outlet pressure P and flow rate Q at different speeds n, as shown in Figure 2.
-
03/16/2023
The Installation and Maintenance of Water Pump
1.Check whether the water pump motor is in good condition. 2.Good airtightness should be ensured between water pump and pipeline.
-
06/29/2023
The Inner Workings of Inverter ACs: How They Save You Money and Keep You Comfortable
Air conditioning is an essential part of modern life, especially in hot and humid climates. However, traditional air conditioners can be very inefficient, consuming a lot of energy and driving up electricity bills.