LS/LG HMI XP70-TTA/DC
Type: HMI
Brand: LS-LG
There is no price at present, you can Request a Quote
Type: HMI
Brand: LS-LG
There is no price at present, you can Request a Quote
Type: HMI
Brand: LS-LG
There is no price at present, you can Request a Quote
Fuji HMI Industrial Touch Screen V710C
Siemens HMI 6AV6 545-0CC10-0AX0
Weintek HMI TK6070iK3WV
Siemens HMI 6AV2 124-1GC01-0AX0
Yaskawa Servo Motor SGMJV-02ADABC
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Lenze Servo Drive EVS9327-CKV003
Balluff Sensor BES00H0
ABB IGBT Module 5SNA060065G0122
Mean Well Power Supply ERP-350-36
MitsubishiServo DriveMR-J2-03B5
09/05/2020
The air compressor air filter (also known as style) is composed of an air filter assembly and a filter element. The outside is connected to the air compressor's intake valve through a joint and a threaded tube to filter the dust, particles and other impurities in the air.
09/15/2020
Sensor, field lightning protection transmitter okmarts.com pressure sensor, okmarts.com pressure transmitter, okmarts.com pressure sensor PTH601 uses diffused silicon piezoresistive core or ceramic piezoresistive core, 316 stainless steel structure, mainly suitable for rivers, groundwater levels, reservoirs, water towers and containers, etc. liquid level measurement and control.
06/20/2020
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
07/13/2020
Danfoss medium temperature refrigeration compressor M series Danfoss MLZ/MLM compressors are specially designed for medium temperature refrigeration applications, using a unique scroll design, providing a variety of refrigerant options (R404A, R134a, R507, R22) cooling capacity covers 2 to 10 horsepower.
08/25/2020
First, prepare all tools and emergency supplies before operation. Such as ammonia tanks or a certain number of ammonia bottles, scales, connecting pipes, fitter tools, gas masks, rubber gloves and first aid medicines.
06/10/2022
The solenoid valve coil generates a magnetic field. This moves a ferromagnetic plunger inside the valve which opens or closes the valve. When a coil (solenoid) is defective, it can be difficult to find a replacement for the original.
09/05/2023
A variable speed heat pump is a heating and cooling system that can adjust its output based on the needs of your home. Unlike traditional HVAC systems
02/27/2021
The temperature of the motor is too high or the motor is faulty with smoke the reason: 1). Excessive load 2). Two-phase operation
07/08/2020
Manufacturing Indonesia is Indonesia’s largest international manufacturing exhibition providing a professional business platform for Indonesia’s manufacturing industry. Incorporating Machine Tool Indonesia, Tools & Hardware Indonesia and Industrial Automation & Logistics Indonesia, the event provides the most cost-effective way to increase your business in South East Asia’s biggest manufacturing market.
08/25/2020
Recently, the technicians of the DCC device have undergone transformation. The temperature of the small turbine bearing box of the propylene compressor oil station of the device has dropped from 90-120 degrees Celsius to 70-85 degrees Celsius