Series | JH Series |
Type | Heavy Industries Compressor |
Refrigerant | R22 |
Phase | 3PH |
Volt | 200-230V |
Hz | 60Hz |
Shipping cost is not included
The Mitsubishi Compressor is high quality!
Mitsubishi Compressor JH513TEB
People who bought this item also viewed
Copeland Compressor ZB38KCE-TFD-265
Tecumseh Compressor AJA7441AXD
Toshiba Compressor PA200X2CS-3MUU
Hitachi Compressor G402DHV-64A1
Mitsubishi Compressor SNB130FGBMT
Mitsubishi Compressor RB154GHAC
Mitsubishi Compressor TNB306FPGMC-L
Mitsubishi Compressor RB154TDG
Bitzer Compressor 4G-20.2
Bristol Compressor H7NG294DPEF
Danfoss Compressor MT80HP3CVE
Copeland Compressor ZB21KQ-TFD-524
TRIAD Transformer F-360U
Siemens Contactor 3RT1066-2AT36
Nidec Fan E34390-16HP
MABUCHI Electric Motor RS-500TB
Danfoss Sight Glass SGN10S
FRANKE Capacitor BSMJ0.69-20-3
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
DHF Tool for Metal Cutting RTB0805
Nemicon Encoder OVF-1024-2MHC
SKF Oil Seal 65X120X10 HMS5 V(FKM)
Yaskawa Servo Motor SGMJV-08A3A2C
Recent related posts
-
07/26/2020
The return pipe and compressor of cold storage are frosted. Why?
Yesterday, the reason for the frosting of the air-conditioning compressor and the compressor was released. Someone left us a message. I hope we can analyze the reasons for the frosting of the return pipe of the cold storage and the compressor.<br></br>
-
01/02/2021
Uncover counterfeits - by product type-Coils
Fake coils for solenoid valves could cause serious damage to your refrigeration system. Identifying Danfoss genuine coils is not difficult – but attention to detail is key here.
-
06/13/2020
Capillary
The capillary tube is the simplest throttling device. The capillary tube is a very thin diameter red copper tube with a specified length. Its inner diameter is generally 0.5 to 2 mm. Characteristics of capillary tube as throttling device
-
07/17/2020
Reasonably adjust the cold storage evaporator and defrost in time
Reasonably adjust the cold storage evaporator and defrost in time Generally speaking, every increase in the cold storage evaporation temperature can save energy Therefore, under the premise of satisfying the low refrigeration process of the product, the evaporation temperature can be increased as much as possible by adjusting the amount of liquid supplied. The thermal resistance of the frost layer is generally much larger than the thermal resistance of the steel pipe.
-
07/02/2020
Danfoss US Youle MANEUROP compressor MTZ-28 latest offer wholesale parameters performance introduction
Danfoss US Youle MANEUROP compressor MTZ-28 latest offer wholesale parameters performance introduction Danfoss US Youle MANEUROP compressor MTZ-28 offer wholesale parameters, distributor Technical parameters of Meiyou compressor:
-
02/27/2021
Working principle of servo motor (how servo motor works)
The rotor inside the servo motor is a permanent magnet. The U / V / W three-phase electricity controlled by the driver forms an electromagnetic field. The rotor rotates under the effect of this magnetic field. At the same time, the encoder of the motor feeds back the signal to the driver. The driver adjusts the rotation angle of the rotor according to the comparison between the feedback value and the target value. The accuracy of servo motor depends on the accuracy of encoder (number of lines).
-
06/19/2020
How good is the air conditioning dehumidification
Nowadays, the temperature of some air conditioners is set actively by the manufacturer during dehumidification. Under the dehumidification method of this type of air conditioner, the control circuit will first check the room temperature, and then set the operating temperature policy value. The setting value of the factory plan is usually the policy value of the operation arrival It is 2 degrees lower than the room temperature. If the setting is too high, the dehumidification effect is not significant. In order to prevent overheating and lowering the room temperature during dehumidification, this set value is usually judged. At this time, we do not need to set the temperature, just open the air conditioning dehumidification function.<img src="{{media url="How_good_is_the_air_conditioning_dehumidification.jpg"}}" alt="" />
-
06/13/2020
11 common protection devices for refrigeration compressors
11 common protection devices for refrigeration compressors When the compressor is running, some abnormal conditions may occur, such as: the discharge pressure is too high
-
12/05/2020
Selection of compressed air dew point meter
Air compressor dew point meter-suitable for compressed air and compressor post-processing drying equipment dew point meter, Michell products include a variety of online dew point meter and portable dew point meter, as well as dew point meter analysis system, fast response speed and good reliability.
-
06/16/2022
What is A VFD?
A Variable Frequency Drive (VFD) is a type of motor controller that drives an electric motor by varying the frequency and voltage supplied to the electric motor.