Analyze the reason why the constant temperature and humidity box is not cooling

Analyze the reason why the constant temperature and humidity box is not cooling Some people think that the constant temperature and humidity chamber is not cooling and the price of the constant temperature and humidity test chamber. Let's take a look at it below. Reason one: Since the constant temperature and humidity box cannot maintain the temperature, observe whether the refrigeration compressor can be started during the operation of the test box and the compressor can be started during the operation of the environmental test equipment, indicating that the electrical circuit from the main power supply to each compressor is normal There is no problem in the electrical system. 2. There is no problem with the electrical system, continue to check the refrigeration system. First check the discharge and suction pressure of the low-temperature (R23) compressors of the two refrigeration units are lower than normal, and the suction pressure is evacuated, indicating that the main refrigeration unit has insufficient refrigerant quantity. 3.Touch the exhaust and suction lines of the main unit R23 compressor by hand, and find that the temperature of the exhaust line is not high, and the temperature of the suction line is not low (no frost), which also shows the main unit The lack of R23 refrigerant. 4.Reason two: 1. The cause of the failure is not determined, and the cause of the failure is further confirmed in conjunction with the control process of the test box. The test box has two sets of refrigeration units. 2. One is the main unit and the other is the auxiliary unit. When the cooling rate is large, the two groups of units work at the same time. At the beginning of the temperature maintenance stage, the two groups of units still work at the same time. After the temperature stabilizes, the auxiliary unit stops working, and the host group maintains the temperature stability. If the host group R23 leaks, the cooling effect of the host group will be insignificant. Since the two units are working at the same time during the cooling process, there is no phenomenon that the temperature is not stable, and the cooling rate is indicated to decrease. In the temperature maintenance stage, once the auxiliary unit stops working and the main unit has no cooling effect, the air in the test chamber will slowly rise. When the temperature rises to a certain level, the control system will start the auxiliary unit to cool down and reduce the temperature to the set point. Near the fixed value (-55 ℃), and then the auxiliary unit stops working again, and so repeatedly, a malfunction will occur. 3.So far, it has been confirmed that the cause of the production failure is the leakage of refrigerant R23 of the low-temperature (R23) class unit of the host group. The leak detection of the refrigeration system was checked by a method combining a leak detector and soapy water, and it was found that the stem of a hot gas bypass solenoid valve was cracked by a slit of about 1 cm. Replace the solenoid valve, recharge the system with fluoride, and the system operates normally. As can be seen from the above, the analysis and judgment of the fault phenomenon are basically easy to difficult. The analysis and judgment of the "outer" then "in", "electrical" and then "cooling" are familiar and familiar. Understanding the principle and working process of the test chamber is the basis for analyzing the fault and judging the fault.

Recent related posts

Customers frequently viewed