Before replacing the compressor, remember to do 10 things first, remember 1. Before replacing, you must check the cause of the damage to the original refrigeration compressor and replace the defective parts. Because damage to other components will directly cause damage to the refrigeration compressor, remember! 2. After the original damaged refrigeration compressor is removed, the system must be blown with nitrogen before it can be connected to the new refrigeration compressor system. 3. During the welding operation, in order to prevent the oxide film from forming on the inner wall of the copper pipe, it is recommended to pass nitrogen gas, and the time for the nitrogen gas to pass should be sufficient. 4. When replacing the refrigeration compressor or other parts, it is forbidden to use the refrigeration compressor as a vacuum pump to evacuate the air in the external unit pipeline, otherwise the refrigeration compressor will be burned, and the vacuum pump must be used to draw a vacuum. 5. When replacing the refrigeration compressor, it is necessary to add freezing oil that matches the nature of the refrigeration compressor, and the appropriate amount of freezing oil is appropriate. Generally speaking, new original compressors have freezing oil. 6. When replacing the refrigeration compressor, the drying filter must be replaced in time. Because the desiccant in the desiccant filter is saturated, the water filtering function is lost. 7. The refrigeration oil in the original system must be cleaned, because the new pump has been injected with sufficient production of refrigeration oil, and different brands of refrigeration oil cannot be mixed, otherwise it will deteriorate and cause poor lubrication, causing the refrigeration compressor to pull the cylinder and turn yellow. , Burnt. 8. When replacing the refrigeration compressor, pay attention to prevent the excessive amount of freezing oil in the system, otherwise it will cause the heat exchange effect of the system to be reduced, which will make the system pressure higher and damage the system and the refrigeration compressor. 9. Don't fill the refrigerant too fast, otherwise it will produce liquid shock, which will cause the valve slice to break, causing pressure loss in the refrigeration compressor. 10. After the installation is completed, the compressor should be checked for normal operation, such as: suction pressure/temperature, discharge pressure/temperature, oil pressure differential pressure and other system parameters. If the parameter exceeds the normal value, the cause of the abnormal system parameter must be clarified.
Before replacing the compressor, remember to do 10 things first, remember
Recent related posts
-
07/20/2020
Before replacing the compressor, remember to do 10 things first, remember
Before replacing, you must check the cause of the damage to the original refrigeration compressor and replace the defective parts. Because damage to other components will directly cause damage to the refrigeration compressor, remember!
-
07/20/2020
What are the specific operation methods for the maintenance of cold storage screw compressors?
Before the cold storage screw compressor must be overhauled, if possible, unload the slide valve to the "0" position, shut down normally, and cut off the power supply. The pipeline connected to the compressor should be cut off and the refrigerant and lubricating oil in the compressor should be discharged before the compressor can be disassembled.
-
07/20/2020
Screw refrigeration compressors are prone to these types of failures, have you encountered them?
The compressor is a volumetric compressor.Since its use in 1934, it has a dominant position in small to large and medium-sized refrigeration systems because of its excellent performance, not suitable for wear, and large unit cooling capacity.
-
07/20/2020
From enclosure to seize share, half-sealed screw harvests markets above 40P
In the industry, many people think that the semi-closed piston is like a stable big brother.
-
07/20/2020
How does a refrigeration compressor work? Introduction to the working principle of a refrigeration compressor【Detailed explanation】
Refrigeration compressors are devices that are often used in our industrial industry and in life, such as air conditioners, refrigerators, etc., all have a refrigeration function. Traditional refrigeration equipment must be equipped with a refrigeration compressor, and the quality of the refrigeration function is concerned with refrigeration The quality of the compressor, so we must understand the performance of the refrigerator when we buy refrigeration products. Let's take a look at the specific content of the refrigerator.
-
07/20/2020
Performance index of electronic expansion valve:
Advantages of electronic expansion valve: The energy efficiency ratio is improved during high-frequency and low-frequency operation; the reliability of the compressor is improved, and the conditions of oil return, l
-
07/20/2020
What brand of refrigerator compressor is the best? Ranking of eight refrigerator compressor brands
Do you know what is the most important part of the refrigerator? Of course, it is the compressor. The refrigerator can work normally because of it. It can be said that the compressor is the core component of the refrigerator.
-
07/20/2020
How to judge the starter of the refrigerator compressor is broken
1. The heavy hammer starter, the part that is easily damaged is the poor contact of the start contact. During the measurement, the weight starter can be removed and measured with a multimeter ohm block according to the original installation direction.
-
07/20/2020
The performance of the refrigerator compressor is broken
The performance of the refrigerator compressor is broken The refrigerator compressor is the heart of the refrigerator and the core component of the refrigerator. If the refrigerator compressor does not work, the entire refrigerator will not run.
-
07/20/2020
Air conditioning sensor principle and application
The temperature sensor used in air conditioning mainly uses a negative temperature coefficient thermistor (also known as NTC thermistor). The temperature sensor is made of manganese, cobalt, nickel, copper and other metal oxides as the main materials,