Common failures and maintenance of overload protectors for air-conditioning compressors Overload protector of air conditioner compressor Installed between the active and passive sides of the power transmission, when an overload fault occurs (torque exceeds the set value), the torque limiter will separate, thereby effectively protecting the driving machinery and the load. Just like its name, the fundamental function of the overload protector is to protect the air-conditioning compressor. Common failures of overload protectors include: heating wire burnout, contact burnout, contact break after the change of stress in the bimetallic sheet cannot be reset, insulation damage of the embedded overload protector and contact failure. The causes of overload are: (2) The source voltage is too low and the symmetry of the three-phase voltage is poor. ⑶ The air conditioner compressor motor runs at low speed for an extended period of time. ⑷Long-term low voltage and load operation of air conditioner compressor motor. ⑸ The cooling medium passage of the air conditioner compressor motor is blocked. ⑹ The ambient temperature is too high. Check the overload protector with a multimeter. Under normal circumstances, there should be a resistance value of tens of ohms. If the resistance value is infinite, it means that the overload protector is open. After the overload protector fails, except for poor contact and contact adhesion can be repaired, other failures are generally not repaired, only replaced and updated. After the built-in overload protector breaks down, it is generally difficult to repair or replace. It can only be replaced together with the air-conditioning compressor. In three-phase air-conditioning compressor motors, the three-phase overload protectors used are mostly bimetallic. The bimetallic element is connected in series with the contactor coil and low-voltage (24V) line of the air-conditioning compressor. The electric heating wire is connected in series with the compressor contactor and the motor connector (in the power circuit). When the metal sheet feels overheating or overcurrent, the bimetallic sheet can cut the motor circuit of the compressor. The above is the overload protector of the air conditioner compressor
Common failures and maintenance of overload protectors for air-conditioning compressors
Recent related posts
-
07/16/2020
Common failures and maintenance of overload protectors for air-conditioning compressors
Overload protector of air conditioner compressor Installed between the active and passive sides of the power transmission, when an overload fault occurs (torque exceeds the set value), the torque limiter will separate, thereby effectively protecting the driving machinery and the load. Just like its name, the fundamental function of the overload protector is to protect the air-conditioning compressor.
-
07/16/2020
Main features of semi-closed scroll compressor
1. On-site maintenance: The shell of the half-sealed scroll compressor can be disassembled, and the horizontal cast iron body is fixed by bolts. 2. Patented flexible scroll technology: compact structure, extremely low vibration-quiet operation and higher tolerance to liquids and magazines.
-
07/16/2020
Vacuum leak test method for small cold storage equipment
Refrigeration systems with evaporating pressure gauges close to or below atmospheric pressure must be tested for vacuum leak tests, leaving the refrigeration equipment under proper vacuum for a certain period of time, reflecting and observing whether air has penetrated into the system from the reading of the vacuum pressure gauge for inspection The sealing performance of the cold storage equipment system.
-
07/15/2020
What is the principle of air conditioning and refrigeration
When the temperature is relatively high in the hot summer days, I believe many of them are also inseparable from the air conditioner. In the summer, it can be said that this life is given by the air conditioner. Everyone knows that the air conditioner can cool and heat, and can adjust the temperature according to your own settings to give yourself a comfortable feeling. However, few people know what is the principle of air conditioning and refrigeration? here we come to find out.
-
07/15/2020
ZP485KCE-TWD|40 HP 50Hz air conditioner Emerson Copeland compressor
Today's editor will introduce the Emerson Copeland compressor ZP485KCE-TWD, which is suitable for R410A refrigerant at 50Hz single-phase electric air conditioning. The power given in the manual of Emerson Copeland Scroll Air Conditioner Compressor is 40 hp. Other technical parameters can be downloaded from our company's website to download the product manual.
-
07/15/2020
ZP725KCE-TWD60 HP 50Hz air conditioner Emerson Copeland compressor
Today's editor will introduce the Emerson Copeland compressor ZP725KCE-TWD, which is suitable for R410A refrigerant at 50Hz single-phase electric air conditioning. The power given in the manual of Emerson Copeland Scroll Air Conditioner Compressor is 60 hp. Other technical parameters can be downloaded from our company's website for inquiries.
-
07/15/2020
ZP31K5E-TF52.6 hp 60Hz (R410A) air conditioner Emerson Copeland compressor
What the editor will introduce today is the Emerson Copeland compressor ZP31K5E-TF5, which is suitable for R410A refrigerant at 60Hz three-phase electric air conditioner. The power given in the manual of Emerson Copeland Scroll Air Conditioner Compressor is 2.6 hp. For other technical parameters, please download the product manual on our company website for self-inquiry.
-
07/15/2020
ZP36KSE-TF53.0 HP 60Hz (R410A) air conditioner Emerson Copeland compressor
Today I will introduce the Emerson Copeland compressor ZP36KSE-TF5, which is suitable for R410A refrigerant at 60Hz three-phase electric air conditioning. The power given in the manual of Emerson Copeland Scroll Air-Conditioning Compressor is 3.0 HP. Other technical parameters can be downloaded from our company's website for inquiries.
-
07/15/2020
ZP42KSE-TF53.5 HP 60Hz (R410A) air conditioning operating conditions Emerson Copeland compressor
The editor today will introduce the Emerson Copeland compressor ZP42KSE-TF5, which is suitable for R410A refrigerant at 60Hz three-phase electric air conditioning. The power given in the manual of Emerson Copeland Scroll Air Conditioner Compressor is 3.5 hp. For other technical parameters, please download the product manual on our company website for self-inquiry.
-
07/15/2020
ZP49KSE-TF74.1 horsepower 60Hz (R410A) air conditioner Emerson Copeland compressor
Today I want to introduce the Emerson Copeland compressor ZP49KSE-TF7, which is suitable for R410A refrigerant at 60Hz three-phase electric air conditioner. The power given in the manual of Emerson Copeland Scroll Air Conditioner Compressor is 4.1 hp. Other technical parameters can be downloaded from our company's website to download the product manual.
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
ESTUN Servo Motor EMG-10DSB22
SANGEE Fan SJ5115HA1
Meas Transmitter M5164-000005-100PG
Rockwell Allen-Bradley AB VFD 22D-E6P6N104
Omron PLC CP1W-20EDT