Failure Analysis of Air Conditioner Button Circuit
Where is the button circuit in the inverter air conditioner? The first is the function keys on the display board, and the second is the automatic switch on the main board. The main purpose is to transmit user instructions and achieve the purpose of information interaction. So, how does it work? What are the common after-sales failures? This article is through the analysis of the circuit, hoping to give you some help in the after-sales maintenance.
1. Circuit principle
When the button is off, there is no loop on the circuit, and the single-chip microcomputer is in a high level state; when the button is pressed on, the 5v direct current is connected to the power ground through R1, forming a loop, and the PIN port is in a low level state. . In this way, the microcomputer can receive the user's button information. Some use membrane buttons, the upper and lower membranes are coated with conductive rubber circuits, and there is a membrane in the middle with holes to isolate the two membranes with conductive rubber. The button is in the position of the hole. When the button is pressed, two films with conductive rubber pass through the round hole in the middle, connect the circuit, and output through the chip code.
2. Common faults
Case number one
Fault phenomenon: A wall-mounted air conditioner automatically restarts after being used for a period of time.
Reason analysis: There are three situations for automatic reset, the first is that the first is too low; the second is electromagnetic interference; the third reset button circuit is faulty.
Troubleshooting: Check the power supply and find no abnormalities; check the surroundings and find no sources of electromagnetic interference. After checking the automatic switch, it was found that it was in the joint state, and the switch was mainly connected to the reset circuit of the single-chip microcomputer. After further analysis, it was found that the switch had silver ion migration.
Case 2
Fault phenomenon: A 2-hp cabinet machine has a button failure fault.
Cause analysis: General inspection found that the button failed but the display was normal, so the power supply should be normal. Further inspection found that the button was corroded and broken.
Troubleshooting: Replace button
Three, additional knowledge points
1. In order to avoid accelerating the generation of electromigration, the manufacturer will set the effective time of the automatic button as 5 minutes after power-on, after which the button will be invalid.
2. After-sales maintenance can judge the type of problem according to the phenomenon, for example, the reset phenomenon is an automatic button, and the display panel button is abnormal when the function is abnormal.
3. Some buttons are dirty, which can be cleaned with alcohol, or foreign objects can also be cleaned.
Failure Analysis of Air Conditioner Button Circuit
Recent related posts
-
07/31/2020
Failure Analysis of Air Conditioner Button Circuit
Where is the button circuit in the inverter air conditioner? The first is the function keys on the display board, and the second is the automatic switch on the main board. The main purpose is to transmit user instructions and achieve the purpose of information interaction.
-
07/31/2020
Common problems and solutions of industrial chillers summarized by the maintenance master
1. Water leakage (first determine the location of the water leakage)<br></br> 1. Water leakage from the pump (causes: the shaft seal at the water pump is not well connected or the shaft seal has been damaged)
-
07/31/2020
Refrigeration principles of refrigerators and air conditioners
Refrigerator is a kind of refrigeration equipment that keeps a constant low temperature, and it is also a civilian product that keeps food or other items in a constant low temperature and cold state. There are cabinets or boxes for freezing by compressors and ice machines, and storage boxes with refrigeration devices
-
07/31/2020
What to do if the compressor of screw chiller is damaged
The compressor is the core component of the chiller. Damage to the compressor is a serious fault and needs to be dealt with in time, otherwise the chiller will not work. Today, the editor will introduce the knowledge and process of handling damaged screw compressors.
-
07/31/2020
Key points for safe operation of refrigeration operators in large cold storage
Generally, safe operating procedures should be formulated for the machines and equipment of refrigeration equipment, and refrigeration operators must strictly abide by them to ensure safe production.
-
07/31/2020
What are the specific operation methods for maintenance of screw compressors in cold storage
Before the cold storage screw compressor must be overhauled, if possible, unload the slide valve to the "0" position, shut down normally, and cut off the power supply.
-
07/31/2020
Principle analysis of monitoring system for cold and heat source equipment
The building automation system is an integrated system platform, in which many subsystems have diverse functions and complex engineering. What is the principle of the cold and heat source equipment monitoring system as one of the many subsystems of the building automation system?
-
07/31/2020
How to fix Samsung air conditioner failure
In recent years, Samsung has continued to develop electronics very well. Samsung air conditioners are also outstanding among air conditioner brands, and they are an air conditioner brand that many consumers will freely choose
-
07/31/2020
Must know! Safe operation of refrigeration valves
The switching operation of various valves is the main task in the operation of the refrigeration system. The function of the valve is to control and guide the flow and direction of the refrigerant in the system, cut off and conduct the connection between the equipment and the equipment or the equipment and the outside world.
-
07/30/2020
About inverter air conditioner fault repair skills
Today I will share with you the maintenance ideas and cases about the failure of the inverter air conditioner that does not heat but can cool. If you like, you can like it and collect it, thank you!!!<br></br>
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
HAIWU Air Conditioner CMA1025U1E
Siemens Contactor 3RA2416-8XF31-1BB4
ADDA Fan AD0605HX-D71GL
Amico Check Valve H44T-16Q DN80
Eaton Vickers Vane Pump 3525V-38A17-86BB22R