Heat Pump Compressor Not Running: Common Issues and Solutions

heat pump outdoor unit on the grass land

Figure 1: Heat pump outdoor unit.



A heat pump is an energy-efficient heating and cooling system that relies on the process of heat transfer to maintain comfortable indoor temperatures. The compressor is an essential component of the heat pump, responsible for raising the pressure and temperature of the refrigerant, allowing it to absorb and release heat.

However, if your compressor for heat pump is not running, it can lead to a variety of problems, including insufficient heating or cooling. In this article, we will discuss common issues that can cause a heat pump compressor to stop running and provide practical solutions to resolve them.

1. Thermostat Issues

1.1 Faulty Thermostat Wiring

A common cause for a heat pump compressor not running is faulty thermostat wiring. The thermostat is responsible for sending signals to the compressor to start or stop. If there is a problem with the wiring or the thermostat itself, it may not be able to send the correct signal, causing the compressor to malfunction.

Solution: Check the thermostat wiring for any visible damage or loose connections. If you find any issues, repair or replace the wiring accordingly. If the thermostat is old or damaged, consider replacing it with a new one.

1. 2 Incorrect Thermostat Settings

If your compressor for heat pump is not running, it could be due to incorrect thermostat settings. The thermostat might be set to "off" or "fan only," which would prevent the compressor from operating.

Solution: Ensure that the thermostat is set to "heat" or "cool" mode, depending on your needs, and the desired temperature is correctly set.



air source heat pump thermostat with Chinese and English interface

Figure 2: Heat pump thermostat.

2. Power Issues

2.1 Tripped Circuit Breaker or Blown Fuse

A tripped circuit breaker or blown fuse can cut off the power supply to the heat pump compressor, causing it to stop running.

Solution: Check your home's electrical panel for any tripped circuit breakers or blown fuses. Reset the circuit breaker or replace the fuse if necessary. If the problem persists, consult a professional electrician to identify and fix any underlying electrical issues.

2.2 Broken or Damaged Power Switch, Capacitor, Relay, or Contactor

A broken or damaged power switch can prevent the compressor for heat pump from receiving power, causing it not to run.
A faulty capacitor can prevent the compressor from receiving the initial electrical boost it needs to start up.
A bad relay can prevent the compressor from receiving the signal to start up.
The contactor is responsible for sending the electrical signal to the compressor to start up, and if it is faulty, it can prevent the compressor from running.

Solution: Inspect these components for any damage, and replace them if necessary. If you're unsure about how to replace a power switch, consult a professional HVAC technician.



Schneider contactor

Figure 3: Schneider contactor.

3. Refrigerant Issues

3.1 Low Refrigerant Levels

Low refrigerant levels can cause the heat pump compressor to overheat and shut down to protect itself from damage. This is often due to refrigerant leaks in the system.

Solution: Inspect the heat pump for any visible refrigerant leaks. If you find any leaks, contact a professional HVAC technician to repair the leaks and recharge the refrigerant. Do not attempt to refill the refrigerant yourself, as this requires specialized knowledge and equipment.

3.2 Blocked or Dirty Refrigerant Lines

Blocked or dirty refrigerant lines can restrict the flow of refrigerant, causing the compressor to work harder and eventually stop running.

Solution: Inspect the refrigerant lines for any blockages or dirt buildup. Clean them as necessary, and if the problem persists, consult a professional HVAC technician for further assistance.

4. Mechanical Issues

4.1 Worn or Damaged Compressor Components

Over time, the compressor's components can wear out or become damaged, leading to poor performance or complete failure.

Solution: Regularly inspect the compressor for signs of wear or damage, such as unusual noises, vibrations, or leaks. If you notice any issues, contact a professional HVAC technician to diagnose and repair the problem.



new original Copeland heat pump compressors

Figure 4: Copeland heat pump compressors.

5. Frozen Evaporator Coil

A frozen evaporator coil can cause the compressor for heat pump to overwork and eventually stop running.

Solution: Check the evaporator coil for ice buildup. If you find ice on the coil, turn off the heat pump and allow the ice to melt. Then, investigate the root cause of the issue, such as dirty air filters, low refrigerant levels, or poor airflow, and address it accordingly.

6. Preventative Maintenance

Regular preventative maintenance can help you avoid issues with your heat pump compressor not running. Schedule routine tune-ups with a professional HVAC technician to ensure your heat pump runs efficiently and effectively.

Regular maintenance tasks include cleaning or replacing air filters, inspecting and cleaning coils, checking refrigerant levels, and inspecting electrical connections.

7. Conclusion

A heat pump compressor not running can lead to uncomfortable indoor temperatures and increased energy bills. By understanding the common issues that can cause a compressor to stop running and taking proactive steps to address them, you can ensure your heat pump operates optimally and maintains a comfortable living environment.

If you're unsure about how to diagnose or fix any of the issues discussed in this article, it's best to consult a professional HVAC technician for assistance.

Related Info

HVAC Compressor 101: Working Principle, Types, Function
Heat Pump Compressor Not Turning On: Common Causes and Fixes
Why Heat Pump Compressor Starts Then Stops: Common Causes and Solutions
A Comprehensive Guide to the Essential Parts of an Air Conditioning System
Don't Sweat It: How to Troubleshoot and Fix an AC Blowing Warm Air

Recent related posts

Customers frequently viewed

Submitted Successfully
Submission Failed