Heat Pump Makes Loud Noise When Turning Off: Causes and Solutions

air source heat pump unit

Figure 1: Air source heat pump.



A heat pump is an essential part of many homes, providing both heating and cooling to keep the indoor environment comfortable. Like any other appliance, it can sometimes develop issues that require attention. One common problem that homeowners may face is a heat pump making loud noise when turning off.

This article aims to help you understand the possible causes of this issue and offer potential solutions to restore your heat pump to its normal, quiet operation.

1. Introduction to Heat Pumps

Heat pumps are energy-efficient systems that transfer heat from one location to another. They can be used for both heating and cooling purposes and are especially popular in areas with moderate climates.

During the heating season, a heat pump extracts heat from the outdoor air and transfers it indoors, while in the cooling season, it does the opposite.

Heat pumps rely on a series of components, including compressors, fans, and refrigerant lines, which can sometimes cause noise if they are not functioning correctly.



Schematic diagram of the working principle of an air source heat pump

Figure 2: Air source heat pump working principle diagram.

2. Causes of Heat Pump Making Loud Noise When Shutting off

There are several reasons why your heat pump may make a loud noise when turning off. Some of these causes include:

2.1 Dirty Air Filter

One of the most common causes of a loud noise when turning off a heat pump is a dirty air filter. When the air filter is clogged with dirt and debris, it can restrict airflow, causing the system to work harder than necessary. This extra strain can cause the system to make a loud noise when shutting down.

2.2 Loose Components

Another possible cause of a loud noise when turning off a heat pump is loose components. Over time, the vibrations from the system can cause screws and other fasteners to loosen. If left unchecked, these loose components can rattle around and create a loud noise when the system turns off.

2.3 Faulty Fan Motor

If your heat pump makes a loud noise when turning off, it could be due to a faulty motor. The motor is responsible for powering the system's fan, and if it is not functioning correctly, it can create a loud noise when shutting down.



air source heat pump cooling fan motor used in the air conditioning

Figure 3: Air source heat pump fan motor.

2.4 Refrigerant Issues

If your heat pump makes a hissing or bubbling noise when turning off, it could be due to refrigerant issues. Refrigerant is essential for the heat pump to transfer heat between the indoor and outdoor units. If there is a refrigerant leak or low refrigerant levels, it can cause a hissing or bubbling noise when the heat pump turns off.

2.5 Dirty Coils

Over time, the coils on your heat pump's outdoor unit can become dirty with dirt, leaves, and other debris. When the heat pump turns off, the fan on the outdoor unit may continue to spin for a few seconds to allow the coils to cool down. If the coils are dirty, the fan may make a loud noise as it spins down.

2.6 Clogged Drain Line

If your heat pump makes a gurgling or bubbling noise when turning off, it may be due to a clogged drain line. The drain line in your heat pump's indoor unit is responsible for removing condensation that is produced during operation. If the drain line is clogged, the condensation can back up and make a gurgling or bubbling noise.

2.7 Compressor Problems

The compressor is a critical component of your heat pump, responsible for compressing and circulating the refrigerant. If the compressor is malfunctioning or has become worn out, it can create loud noises when the heat pump turns off.



Heat pump compressor for air conditioning

Figure 4: Copeland heat pump compressor.

3. Solutions to Heat Pump Making Loud Noise When Shutting off

Now that we have explored some of the possible causes of a loud noise when turning off a heat pump, let's look at some solutions to help you resolve this issue.

3.1 Change the Air Filter

If a dirty air filter is causing your heat pump to make a loud noise when turning off, changing the filter is an easy solution. Locate the air filter in your system and replace it with a clean one. Be sure to check the filter every few months and replace it as needed to keep your system running smoothly.

3.2 Tighten Loose Components

If loose components are causing your heat pump to make a loud noise when turning off, tightening them can help resolve the issue. Check all screws, bolts, and other fasteners in your system and tighten any that are loose.

3.3 Replace a Faulty Fan Motor

If a faulty motor is causing your heat pump to make a loud noise when turning off, it will need to be replaced. This is a more complex repair and should only be attempted by a licensed HVAC technician.

3.4 Repair a Refrigerant Leak

If a refrigerant leak is causing your heat pump to make a loud noise when turning off, it will need to be repaired. A licensed HVAC technician can locate the leak and repair it, ensuring that your system has the proper refrigerant levels and operates quietly.



air source heat pump piping

Figure 5: Air source heat pump piping.

3.5 Clean the coils

Solution: Regular maintenance of your heat pump, including cleaning the coils, can help prevent this issue. If the coils are already dirty, you can use a coil cleaner to remove the debris.

3.6 Clear the Clogged Drain Line

Solution: A professional technician can clear the clogged drain line and ensure proper drainage.

3.7 Clean and Inspect the Compressor

Ensure that the compressor is clean and free of debris, as this can help improve its performance and reduce noise. If you suspect that the compressor is damaged or worn out, consult with a professional technician.



Carry out maintenance and inspection on the central heating equipment of the ground source heat pump device

Figure 6: Maintenance and inspection on ground source heat pump.

4. When to Call a Professional

If you're unable to identify or resolve the issue causing the loud noise in your heat pump, it's best to call a professional technician. They have the experience and tools necessary to diagnose and fix the problem, ensuring that your heat pump operates efficiently and quietly.

5. Preventative Maintenance for Heat Pumps

To help prevent issues with your heat pump, it's essential to perform regular maintenance. This includes:

● Changing the air filter every 1-3 months, depending on use and air quality
● Cleaning the outdoor unit and removing debris from around it
● Having a professional technician perform an annual inspection and tune-up

By taking these steps, you can help prolong the life of your heat pump and minimize the likelihood of experiencing loud noises or other issues.

6. Conclusion

If your heat pump makes a loud noise when turning off, it can be concerning. However, by understanding the possible causes and implementing the solutions discussed in this article, you can resolve the issue and prevent it from occurring in the future. Remember to schedule regular maintenance appointments and keep your system clean to keep it running efficiently and quietly.

Related Info

An Introduction to Heat Pump Parts (with Heat Pump Parts Diagram)
Is Your Heat Pump Making Loud Noise? Here's What You Need to Know
How Does a Scroll Compressor Work? Components, Principles, and Applications
What is a Water Source Heat Pump (with Water Source Heat Pump Diagram)