How should the two-way flow fresh air system be installed
At present, the fresh air system on the market is mainly divided into one-way flow and two-way flow according to the air supply method, and the two different air supply and exhaust forms are actually very different. For example, the one-way fresh air system is installed At that time, air supply and exhaust can be carried out without the need for pipes, and the two-way flow fresh air system needs to be equipped with special air supply and exhaust pipes to achieve the demand for air supply and exhaust. At this time, some people will be curious. , How can this one-way fresh air system be installed conveniently and can achieve the function of a two-way fresh air system? Why do you choose a two-way fresh air system instead of a one-way fresh air system?
In fact, the two-way flow fresh air system is better than the one-way flow fresh air system in terms of air supply and exhaust, and air treatment. The two-way flow fresh air system is more suitable for large indoor places, so many users are choosing the fresh air system. At times, it will be biased towards the two-way flow fresh air system, but the two-way flow fresh air system also needs to pay attention to some problems when installing, so let's learn about the installation knowledge of the two-way flow fresh air fan.
Host installation:
First, according to the floor plan of the house, the layout of the mainframe and the design of the ducts to the air outlets are carried out. Normally, the mainframe will be installed on the ceiling of the bathroom and dressing room, because these are infrequent places, which can avoid the use of noise and isolate the noise. In addition, it is necessary to do a good job of fixing and shock-absorbing treatment during installation to prevent the host from shaking and generating noise during operation, and it is necessary to leave enough space for later maintenance.
Ventilation duct installation:
The direction, diameter and installation position of the duct of the two-way flow fresh air fan should be installed in strict accordance with the requirements of the design drawings, and a special hose should be used for the connection between the fresh air host and the pipe connection, and stick The connection is firm to prevent vibration to the pipeline when the fresh air main engine is running. In addition, the direction of the pipeline should be as horizontal and vertical as possible to avoid bending. When installing the air outlet, pay attention to the distance between the air outlet and the air outlet, try to be more than 3 meters, to avoid short-circuit phenomenon.
How should the two-way flow fresh air system be installed
Recent related posts
-
08/10/2020
How should the two-way flow fresh air system be installed
At present, the fresh air system on the market is mainly divided into one-way flow and two-way flow according to the air supply method, and the two different air supply and exhaust forms are actually very different.
-
08/10/2020
Frostbite, accidental ingestion... first-aid measures for refrigerants that must be mastered
1. Precautions for using refrigerant<br></br> 1. Avoid entering highly concentrated water vapor. Although some refrigerants are not easy to burn under normal temperature and pressure conditions, their mixture can burn or even explode under high pressure and high concentration air conditions.
-
08/10/2020
Four anti-corrosion methods for heat exchangers
There are four main anti-corrosion methods for heat exchangers: corrosion-resistant materials, electrochemical protection, adding corrosion inhibitors, and anti-corrosion coating methods.
-
08/10/2020
Exploring the secrets of refrigerated compartments
As an important transportation equipment in cold chain logistics transportation, refrigerated trucks are the key to ensuring the safety of perishable and fresh food during transportation.
-
08/10/2020
Energy saving tips for air purifiers you should know
As the smog hits in recent years and the air quality continues to decline, air purifiers have gradually become essential household appliances in people's homes. Experts suggest that the air purifier should be turned on for 24 hours.
-
08/10/2020
Do you know the selection of solenoid valve
The selection of solenoid valve should first follow the four principles of safety, reliability, applicability, and economy in order, based on the four principles, and secondly, according to the six aspects of field working conditions
-
08/10/2020
Common faults of refrigerator thermostat
As we all know, the finished product of any mechanical product is composed of scattered parts; from the beginning of assembly, each of their parts has a very important "mission" to complete,
-
08/10/2020
Causes and solutions for ice blocking in supermarket freezer
Nowadays, commercial freezer is one of the necessary equipment in supermarkets to store and display goods; its appearance will undoubtedly bring convenience to more and more demanders;
-
08/10/2020
Benefits and methods of condensate recovery
Benefits and methods of condensate recovery<br></br> 1. Why should we recycle condensate<br></br> Steam as a clean and safe energy carrier is widely used in various industries. After the steam releases the latent heat of vaporization in the steam-using equipment,
-
08/10/2020
Adding method of refrigerant in central air conditioner
Adding method of refrigerant in central air conditioner<br></br> How to add refrigerant to the central air conditioner, what operating methods do you know? Let’s take a look with the editor today!
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
NORGREN Air Cylinder RA/192050/M/100
Symbol Bar Code Scanner DS3508-HD
COSEL Power Supply LFA50F-15-S
SHAKO Air Cylinder JC32B5-M