How to clean the precision air conditioner in the standby room

How to clean the precision air conditioner in the standby room

The precision air conditioner in the computer room is the guarantee of constant temperature and humidity in the data center of the computer room. To ensure the reliability and economy of the operation of the computer room, the precision air conditioner in the computer room needs to be cleaned and maintained regularly.

  1. The cleaning and maintenance of precision air-conditioning in the computer room can remove rust, prevent corrosion and damage to the equipment, and can prevent the equipment from being processed and prolong the service life of the equipment. At the same time, the corrosion rate can be reduced to 90% after the corrosion inhibitor is put in.

  2. After cleaning the precision air conditioner in the computer room, it can completely kill the Legionella bacteria. The air conditioner supplied by the fan coil is fresh and high-quality, which is beneficial to the health of users.

  3. If the precision air conditioner in the computer room is not cleaned in time, there will be pipe blockage, scaling, corrosion, overpressure shutdown, or even failure. If the host leaks due to corrosion or solution contamination, the copper pipe needs to be replaced, the solution is replaced, and the host needs to be repaired.

4. Pan-geographic precision air conditioner computer room monitoring system is composed of three parts: front-end equipment, client/server APP and PC large screen. Users can check the operation status and related parameters of precision air conditioners in real time after logging in through the client APP/PC. . When there are failures such as temperature and humidity return air, supply air limit, etc., the alarm information can be received synchronously, and the fault can be solved quickly.

  5. The cleaning and maintenance of the precision air conditioner in the computer room can disinfect the algae, increase the heat exchange rate between the condenser and the evaporator, prevent high-pressure operation, overpressure shutdown, and increase cold water.

  6. ​​The precision air conditioner cleaning protection in the computer room can eliminate scale, increase heat exchange power, reduce power and fuel consumption by 20%, reduce water treatment and reduce pollution, increase the utilization rate of reclaimed water, and save 60% of water.

   Regular maintenance of the precision air conditioner in the computer room can not only effectively ensure the normal operation of the air conditioner, but also prolong the service life.

Recent related posts

Customers frequently viewed

New In stock for sale, IWAYA DENKI Water Pump 25CJT0752

IWAYA DENKI Water Pump 25CJT0752

US$2307.69
New In stock for sale, ROTEN Mechanical Seal 8E5K-22-X

ROTEN Mechanical Seal 8E5K-22-X

US$384.62
New In stock for sale, ASCO Solenoid Valve B262C035

ASCO Solenoid Valve B262C035

Contact Us
New In stock for sale, Chint Relay JSZ3C-F AC220V

Chint Relay JSZ3C-F AC220V

US$16.54
New In stock for sale, ULVAC Vacuum Pump YTP-150M-DRY

ULVAC Vacuum Pump YTP-150M-DRY

Contact Us
New In stock for sale, FOTEK Sensor MS08-10P

FOTEK Sensor MS08-10P

US$27.30
New In stock for sale, NMB-MAT Fan 11925SA-24N-AA-00

NMB-MAT Fan 11925SA-24N-AA-00

US$35.38
New In stock for sale, APISTEK Fan GA41S2L-NNTF

APISTEK Fan GA41S2L-NNTF

US$3.54
New In stock for sale, Danfoss Compressor MTZ19JA1VE

Danfoss Compressor MTZ19JA1VE

US$4499.10