How to clean the return air duct of central air conditioning
Today, the editor of okmarts.com mainly introduces some of the most commonly used and basic cleaning procedures for central air-conditioning. I hope it will be useful to everyone!
1. Cleaning the air-conditioning ventilation duct system is first layered and cleaned, and then the air-conditioning duct system on each floor is divided into several cleaning construction pipe sections, and the length of each pipe section does not exceed 30 meters.
2. Open a suitable size detection port on the ventilation duct to be cleaned, and then install a detection door independently developed by Huiying Environmental Protection Company. (The size and position of the detection opening must ensure the smooth completion of the detection operation).
3. Each section of the air-separated airbag is put into the two ends of the pipeline to be cleaned, and then the airbag is inflated. The airbag size matches the pipe size to form a sealed space. The airbag is made of rubber.
4. Remove the return air outlet on the air duct of the construction section to be cleaned, and then plug it with a plastic sealing film.
5. Put the above return air outlet and other air outlets together for cleaning.
6. Open a mouth at 30 meters to be used as the suction pipe interface of the vacuum cleaner. Connect the ventilation duct and the vacuum cleaner with a dedicated hose at the connection (the opening position is closer to the air outlet, and the existing air outlet can be used as the suction pipe interface of the vacuum cleaner).
7. Connect the inspection robot with other complete sets of equipment. Put the inspection robot into the air duct to be inspected from the inspection port to detect the internal pollution of the air duct. The monitoring camera unit can see the internal pollution of the air duct from the display. The situation and the entire inspection process are tracked and recorded, and some relevant records are filled in at any time.
8. Connect the suction pipe of the vacuum box and open the vacuum box to make the inside of the pipe in a negative pressure state to further prevent the leakage of pollutants. Create airflow to absorb dirt in the pipeline. At the same time, put the cleaning robot into the cleaning and maintenance duct of the central air conditioner to clean the inner wall of the air duct from near to far. When cleaning, make the brush head or robot enter the pipe along the operation port, and peel off the contaminants attached to the inner wall of the pipe. It can be transported to and absorbed by the airflow produced by the vacuum cleaner. Through the monitoring camera unit, the cleaning inside the air duct and the working condition of the equipment can be seen from the display, so that the lifting height of the robot arm, the roller brush and the direction of travel can be controlled by operating the buttons. Record the entire cleaning process of the air duct and fill in some relevant records.
9. When the air nozzle is used for purging operation, the purging equipment enters the air duct along the operation port to perform high-pressure air purging, and the contaminants are transported by compressed airflow. When necessary, it can be used in conjunction with a cleaning robot, so that the dust in the air duct can be completely sucked out.
10. For the air ducts of the central air conditioning encyclopedia ventilation system with a small size, use electric universal brushes to clean, and use air soft brushes or air nozzles to clean curved ventilation pipe sections and risers. These cleaning and cleaning tools should Work with the high-power dust box to ensure that the dust and debris in the air duct can be effectively sucked out.
11. Clean the fire damper on the ventilation pipe. If it cannot be cleaned, open a hole on the other side of the fire damper to blow with high pressure air. After the purge is completed, keep it warm and restore it to its original shape.
12. Clean the air volume control valve on the ventilation pipe. Do not wash with water to avoid corrosion. After cleaning, restore the heat preservation and air volume adjustment switch to the original state.
13. Cleaning of the diffuser. After completing the cleaning of each section of the ventilation duct, remove all the diffusers and place them in a designated place for centralized cleaning. If the dust is soft and easy to blow off, you can use high-pressure air for blowing. If it is stained with oil and more grease, spray the special cleaning agent on the surface for 5-10 minutes, then wash it with clean water, and then dry it (blow-dry) for installation.
14. Clean the air supply and return air vents. After completing the cleaning of each section of the ventilation duct, remove all the air supply and return air vents, and place them together with other parts in the designated place for centralized cleaning. The cleaning method is the same as above.
How to clean the return air duct of central air conditioning
Recent related posts
-
08/17/2020
How to clean the return air duct of central air conditioning
Today, the editor of okmarts.com mainly introduces some of the most commonly used and basic cleaning procedures for central air-conditioning. I hope it will be useful to everyone!
-
08/17/2020
How to choose chillers for small factories
At present, the chiller industry is continuously accelerating the pace of development. More and more different types of chillers have emerged, and many small chiller factories have been born.
-
08/17/2020
How to choose a compressor when building a cold storage
The compressor is the core of the entire cold storage system. It is the blood and the heart. It is one of the indispensable components in the complete cycle of the entire refrigeration system.
-
08/17/2020
How to check the cooling system of air-cooled chiller
No matter what kind of failure occurs in the chiller, it needs to be paid attention to by the user. Among the many failures, the air-cooled chiller has more ice block failures. This is related to the life cycle of the equipment and the way and method of u碌7館2 䀀 締眪
-
08/17/2020
How to adjust the refrigeration system of cold storage equipment to reduce operating costs
1. Reasonably adjust the operating parameters of the refrigeration system to improve equipment efficiency. The evaporating pressure and temperature of the refrigeration system and the condensing pressure and temperature are the main parameters.
-
08/17/2020
How to achieve higher performance requirements in the design and production process of chillers
Many companies will purchase chillers to meet the refrigeration needs of their own production work. Purchasing high-quality chillers can ensure the stability of the operation and a certain degree of work efficiency, and the service life will be longer.
-
08/17/2020
How can the chiller be more energy-saving and power-saving
With the continuous improvement of living standards, science and technology are also developing steadily. People nowadays are pursuing energy-saving, power-saving, environmental protection,
-
08/17/2020
Frost in industrial chillers should be dealt with in time
When enterprises use industrial chillers, it is easy to find that different types of industrial chillers will have different degrees of frosting failure. A large amount of frost will limit the working efficiency of the evaporator and the equipment is in a碌7館2 䀀 締眪湠眷 V V
-
08/17/2020
Five important points for attention when selecting piston chillers
The main control parameters of piston chillers are energy efficiency ratio, rated cooling capacity, input power, refrigerant type, power supply voltage, etc. Below, the editor of okmarts.com introduces the selection points of piston chillers in detail.
-
08/17/2020
Five elements for safe use of liquid ammonia refrigeration equipment
In recent years, liquid ammonia leakage accidents have occurred frequently, leading to many tragedies. In order to prevent similar accidents, the editor of okmarts.com today takes everyone to understand the five major elements that need attention in the u碌7館2 䀀 締眪湠眷 V V 㠠ǝ
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
FUJITSU Relay FTR-F3AA005E
ARK Air Cylinder KAND-80-60-A-P-A
Balluff Sensor BES02H5
SIEMENS Servo Drive 6SC6110-0GB00
SMC Proportional Valve ITV3050-33F4BN3
YUKEN Vane Pump PV2R4-184-L-RAA-41