Refrigerant filling method of water-cooled screw chiller
The refrigerant plays a vital role in refrigeration equipment. This is something that everyone in this industry needs to understand. What are the refrigerant charging methods for water-cooled screw chillers? Let’s take a look with the editor of okmarts.com today!
Generally, refrigerants can be divided into five categories according to their chemical composition:
1, Freon;
2, unsaturated hydrocarbon refrigerant;
3, saturated hydrocarbon refrigerant;
4. Inorganic compound refrigerant;
5. Azeotrope refrigerant. In these five categories, water-cooled screw chillers usually use R-22 type refrigerant, and the chemical composition is difluorochloromethane. Mainly used in medium and low temperature commercial refrigeration, catering refrigeration, supermarket display cabinets, residential and commercial air conditioning systems.
What are the refrigerant charging methods for water-cooled screw chillers?
After the refrigeration system has been strictly tested and has no leakage, it can be filled with refrigerant. There are two ways to charge refrigerant:
1. Filling from the bypass hole of the compressor discharge valve
is the direct injection of Freon liquid into the system. Its advantage is that the filling speed is fast and safe, and it is suitable for the situation that there is no refrigerant in the system and the vacuum has been evacuated, that is, it is suitable for the first filling. It relies on the pressure difference and height difference between the freon in the cylinder and the system to discharge into the system by itself. If you use this method to infuse freon steam. The injection volume is very small, and only when the liquid is injected can it be injected more and quickly. Moreover, the freon in the bottle is not completely filled. When the pressure in the system is higher than 3KG/MC2, the filling on the high-pressure side should be stopped. If the filling volume is insufficient, it can be filled from the suction side. When filling freon from the high-pressure side, Never start the compressor to avoid accidents.
2. Filling from the compressor suction valve bypass hole
Freon gas is filled from the low pressure side of the compressor, and the compressor must be started. Do not inject liquid refrigerant to avoid liquid shock. This method is suitable for the situation where the system is insufficient to fill up. In our country's general commercial or canteen, the small Freon refrigeration system is usually in the form of a unit, and most of the high-pressure parts are filled with Freon in the manufacturing plant. Therefore, most small Freon devices need to be supplemented with refrigerant. Through the above detailed explanation, let us know what are the refrigerant filling methods for water-cooled screw chillers. We can make corresponding choices based on some real-life problems. This will not only improve our work ability, but also Let us operate the machine very smoothly.

Related Info
Precautions before and after installation of the chiller Precautions for the selection of fan coils for large central air conditioners Reasons and precautions for supporting cooling towers of industrial chillers Reasons for abnormal evaporation temperature of refrigeration equipment Reasons for the high low pressure value of the chillerRefrigerant filling method of water-cooled screw chiller
Subscribe to relevant news content?
Subscription
Unsubscription
Recent related posts
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
US$2307.69
Panasonic Servo Motor MHMF022L1V2M
US$653.85
Honeywell Solenoid Valve VE4025B1045
US$334.62
ROTEN Mechanical Seal 8E5K-22-X
US$384.62
Daikin Solenoid Valve KSO-G02-3BP-20-E
US$393.16
Siemens Contactor 3RT2636-1AB05
US$957.31
Fuji VFD Frequency Converter FRN15F1H-4A111
Contact Us
HOLTEK IC Integrated Circuit Chip HT45F23A
Contact Us
Copeland Compressor CR62KQM-TFD-203
US$800.00
KOYO Encoder TRD-N50-RZV-K001
US$178.57
Toshiba Compressor PA235G2CS-4KTM1
US$299.30