The 8 accessory usages that must be mastered when using computer room air conditioners!
The electrical control and air circulation of the computer room air conditioner are independent units. During maintenance and overhaul, the air conditioner does not need to be turned off, and the stable air flow and temperature gradient in the air conditioner room can also be ensured.
1. Indicator
The liquid moisture indicator of the sight glass provides an accurate way for the user to confirm the quality and moisture content of the refrigerant in the system.
2, switch
The pressure switch is used to protect the refrigeration compressor in the air conditioning system to prevent the compressor's suction pressure from being too low or the discharge pressure from being too high. In addition, the pressure switch is also used to start and stop the condenser fan.
3, expansion valve
The thermal expansion valve is usually installed between the liquid storage cylinder and the evaporator, which can make the high temperature and high pressure liquid refrigerant become low pressure wet vapor through throttling, and then the refrigerant absorbs heat in the evaporator to achieve the cooling effect.
4, refrigerant
In refrigeration and air conditioning systems, a working fluid used to transfer heat energy to produce a freezing effect. The refrigerant liquefies to release heat and vaporizes to absorb heat. If the evaporator and condenser are installed in different positions, the machine will move the heat to different positions.
5. Monitoring
Pan-geographic precision air-conditioning computer room monitoring system is composed of three parts: front-end equipment, client/server APP, and PC large screen. Users can check the operating status and related parameters of precision air-conditioning in real time after logging in through the client APP/PC. When there are failures such as temperature and humidity return air, air supply limit, etc., the alarm information can be received synchronously, and the fault can be solved quickly.
6, pre-filter
The pre-filtration of the ventilation system of the computer room air conditioner, the return air filtration of the clean air-conditioning clean room, the pre-filtration of high-efficiency filtration, and the pre-filtration of air compressors.
7, solenoid valve
Direct-acting solenoid valves can operate normally under vacuum, negative pressure or zero pressure, and are used in refrigeration, pneumatic, water supply, steam and hydraulic systems. The solenoid valve uses a fully plastic solenoid coil and DIN international standard electrical connection equipment, with good insulation, waterproof, moisture-proof, shock-resistant and corrosion-resistant capabilities.
8. Dry filter
The liquid pipe uses a filter drier to protect the refrigeration series from contamination by liquid and solid pollutants. It is equipped with a specially formulated desiccant mixture, which can remove acid and moisture in any refrigeration system.
The computer room air conditioner is one of the important prerequisites to ensure the normal operation of the computer system. The computer room air conditioner adjusts the temperature, humidity and cleanliness of the computer room to create a good operating environment for computer equipment.
The 8 accessory usages that must be mastered when using computer room air conditioners!
Recent related posts
-
07/31/2020
The 8 accessory usages that must be mastered when using computer room air conditioners!
The electrical control and air circulation of the computer room air conditioner are independent units. During maintenance and overhaul, the air conditioner does not need to be turned off, and the stable air flow and temperature gradient in the air conditioner room can also be ensured
-
07/31/2020
Is the refrigerant gas or liquid
Regarding whether to charge the refrigerant, whether it is gas or liquid, many masters must have known for a long time. I often see people inquiring about this refrigerant when charging, is it gas or liquid? Here is a summary. For your reference
-
07/31/2020
What kind of equipment is generally used in cold storage How to select the refrigeration equipment
The cost of cold storage with a refrigeration capacity of less than 60kw is relatively large. It is generally suitable for small cold storage and air conditioning units. The cost of such small cold storage within 100 square meters ranges from 30,000 to 100,000.
-
07/31/2020
What kind of equipment is suitable for high and low pressure refrigerant charging method
There are generally two types of refrigerant charging methods: low-pressure charging and high-pressure charging. The advantage of the low pressure charging method is that it is easier to control the amount of refrigerant charged,
-
07/31/2020
Air conditioner compressor failure Be sure to find out the underlying cause of the compressor failure!
The compressor is the energy core of the air-conditioning refrigeration (heating) system. In the refrigeration system, it mainly plays the role of compressing refrigerant and promoting the continuous circulation of refrigerating oil.
-
07/31/2020
Five common problems of refrigeration system
Trouble phenomenon: The cooling effect of the whole machine is poor, the water outlet is only slightly cool, and the pressure on the high pressure side and the low pressure side are found to be low when checked with the manifold pressure gauge (under the normal speed of the compressor
-
07/31/2020
Responding to the failure of the air conditioning compressor in the computer room, one solution!
The special air conditioner for the computer room is designed based on the characteristics and requirements of the computer room and each communication room. It has the characteristics of constant temperature and humidity, high control accuracy, high air cleanliness and high reliability
-
07/31/2020
Fresh air treatment and energy-saving methods of multi-line system
In the process of using air conditioners, we must consider the related functions of air conditioners on the one hand, and on the other hand, consider its energy-saving effects and reduce power consumption. The multi-line system can meet people’s needs in life while reducing input costs. Reduce energy consumption.
-
07/31/2020
Multi-online display FC, FL, FE fault processing method
Outside machine LED3 double 8 indicator light is on and displays: FC, FL, FE. When the indicator light of the external mainboard and the line controller fail, the following figure will be displayed:
-
07/31/2020
How should centralized air conditioners be used during epidemic prevention and control
Before using the centralized air-conditioning ventilation system, you should understand the type of the centralized air-conditioning ventilation system, the air supply range, and the air intake of the fresh air