The difference between duct air conditioner and split air conditioner
1. What is split air conditioner
Split type is the name to distinguish it from the window machine. The compressor, condenser, evaporator and other components of the window air conditioner are all connected together. Most of the units are single-cooled, with high noise and poor aesthetics, so people have developed split air conditioners. The split-type air conditioner indoor unit has only evaporator, fan, motor, main board and other components, and the rest are all in the outdoor unit. The internal and external units of the split type air conditioner are only connected by refrigerant pipes, which are convenient for construction, high flexibility, beautiful indoor units and low noise. There are wall-mounted and floor-standing indoors, which are more popular than window units.
2. What is a duct air conditioner
ducted air conditioner, its connection form is the same as that of split type air conditioner. It is also an outdoor unit connected to an indoor unit, but the connected indoor unit is in the form of a fan and is mostly installed in the ceiling.
3. The difference between duct air conditioner and split air conditioner:
1. The duct machine is installed in the ceiling and does not occupy valuable indoor air conditioners; while the split floor type air conditioner needs to occupy the ground area, and the pipeline of the wall-mounted air conditioner must be exposed outside.
2. The duct air conditioner is installed in the ceiling. Only the supply air outlet and the return air outlet can be seen outside. The shape and color of the air outlet can be customized according to the installation style and color, and it is perfectly integrated with the decoration; while the split machine, no matter how it is placed or Choose the color, it is so perfect that it can't be combined with the decoration, and it's slightly abrupt.
3. The air-conditioning duct machine delivers air at the top, and its air pressure is greater. With the adjustable louver opening, the airflow can fill the entire room; the air supply angle and coverage area of the split air conditioner are very limited, which is easy to cause The temperature distribution in the room is uneven.
4. After the duct air conditioner is installed, the effect is the same as the central air conditioner, and the grade will be higher.
5. Generally, the installation of duct air conditioner requires a ceiling, which should be installed during decoration; split air conditioners can be installed at any time.
6. Duct air conditioners are generally wired controllers, that is, the air conditioner control panel is installed on the wall; split air conditioners are mostly remote controls.
7. Due to the more complicated construction of ducted air conditioners than split air conditioners, the cost is generally higher than that of split air conditioners.
The difference between duct air conditioner and split air conditioner
Recent related posts
-
08/16/2020
The difference between duct air conditioner and split air conditioner
1. What is split air conditioner Split type is the name to distinguish it from the window machine. The compressor, condenser, evaporator and other components of the window air conditioner are all connected together.
-
08/16/2020
The experience of building a small cold storage correctly, come and learn!
Relying on a series of advantages such as short installation period, fast and efficient use, and reasonable price, the construction of small cold storage has quickly been recognized by the market and has been widely used in many industries.
-
08/16/2020
The failure of refrigeration system in small cold storage
Small cold storage, including movable cold storage, generally have a capacity of less than 100 tons. The cold storage evaporator adopts a platoon type or a combined type of air cooler, and a
-
08/16/2020
The old method of repair and maintenance of screw chiller
With the development of economy and the improvement of production process requirements, screw chillers have become an important aspect of most enterprises’ production cooling needs.
-
08/16/2020
Those things about the chiller cooling tower water distributor
The editor of okmarts.com mentioned in many articles the importance of cooling towers to chillers, and of course, it is the importance of water-cooled chillers. For the cold water tower, it also has its own so-called "important accessories"!
-
08/16/2020
Three selection skills and maintenance tips for chiller equipment
The chiller is a kind of water cooling equipment, by injecting a certain amount of water into the water tank in the machine, the water is cooled by the chiller refrigeration system, and then the
-
08/16/2020
Two major issues that should be paid attention to when installing and wiring fan coil thermostats
The fan coil unit has a compact structure, sturdiness and durability, and usually adopts high-quality galvanized sheet casing. The condensing surface-mounted air duct water pan is integrally formed by a molding process
-
08/16/2020
Ways to improve the service life of control valves
The control valve is not like a manual valve. After it is installed, it is rarely managed and maintained. It must be maintained frequently to ensure normal operation and long service life. Below we introduce eight ways to extend the service life of the control valve.
-
08/16/2020
What are the basic conditions needed to install industrial chillers
With the continuous development of society, many companies have a great demand for refrigeration. The continuous development of science and technology also makes companies
-
08/16/2020
What are the effects of excessively high temperature when exhausting industrial chillers How to solve
The exhaust temperature of the compressor in an industrial chiller determines whether the equipment can operate stably and efficiently. The compressor is prone to excessive exhaust temperature.
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
COSEL Power Supply ADA1000F-30-JR
HONGFA Relay HFD3-I-1.5-L1SR
Siemens Circuit Breaker 3RV1011-1GA15
GOODSKY Relay UA-SS-112D
Sumitomo Gear Pump QT33-12.5F-A