The precursor before the problem of the evaporator in the industrial chiller

The precursor before the problem of the evaporator in the industrial chiller

The overall stability of the various industrial chillers produced in China is very high. As long as the daily maintenance and maintenance of the chillers are carefully completed, the service life of the chillers is very long. In order to better use the chiller, the company needs to conduct careful inspections of the various components of the equipment regularly, and ensure the long-term stable operation of the chiller by troubleshooting in time, and prevent the failure from affecting the normal production of the company.

  First, low cooling performance

   After the industrial chiller has been running for a period of time, if there is a serious drop in cooling performance, it is necessary to conduct a comprehensive inspection of the equipment in time. In the case of troubleshooting the compressor, the main cause of the performance degradation of the industrial refrigerator is usually the evaporator failure, such as the low efficiency of the evaporator, or the dust on the surface of the evaporator, which affects normal operation. As long as the specific cause of the failure can be found and repairs are performed in time, the stable operation of the chiller can be guaranteed.

  Second, energy consumption increased

  When the industrial chiller is operating normally, because there are various data on the operation of the industrial chiller, it is possible to judge the amount of energy consumed by the chiller per unit time. If the energy consumed by the industrial refrigerator continues to increase, it means that the industrial refrigerator may be in a faulty operating state. At this time, comprehensive maintenance and maintenance of the equipment are required, and faults can be found and rectified in time, which is important for improving the safety and operation of the equipment. Stability has an important impact.

   Third, frequent failures

   After using the industrial chiller for more than 2 to 3 years, if the chiller often has various failures, after troubleshooting, after a short period of time, similar failures will continue to occur. Usually, the problem of high incidence of failure is directly related to daily maintenance and maintenance. The normal use of industrial refrigerators within 4 years, as long as they are regularly maintained, the probability of failure is very low. If the failure occurs frequently, timely detection is required to prevent the scope of the failure from expanding.

.    The evaporator failure must be dealt with in time. Since the operating status of the evaporator directly affects whether the equipment can operate normally, it is necessary to carefully check the equipment accessories before operating the chiller. Only by ensuring that the various equipment of the chiller are in normal operating conditions can the service life of the industrial chiller be extended.