What to do if the air conditioner protection light is flashing and not cooling
In the entire home repair industry, what can quickly arouse the attention of users is the previous TV repair, and the current air conditioning repair is also one.
If you don’t believe me, as soon as the four words air-conditioning repair are placed in the search box, the problem of flushing will come out. More specifically, air-conditioning repair does contain too many problems.
Refrigeration is the standard core function of an air conditioner. Once a problem occurs, it will be fatal. Take the question of how to do if the air conditioner protection light flashes and does not cool.
The fatal failure of air-conditioning not cooling has ruined the weekend and rest time of many people. In order to ensure that every family with air-conditioning can be cool for the summer, the reasons and solutions for the air-conditioning protection lights flashing and not cooling have been found out.
The possible cause is the tripping of the compressor protection device. The compressor overload protection tripping means that the high pressure of the system is too high or the overheating current is too large.
Reasons for high pressure and overheating and troubleshooting:
1. Too much refrigerant. Appropriately reduce the amount of refrigerant.
2. Poor heat dissipation. Check whether there is dirt on the condenser tube and clean the condenser.
3. The pipeline system is blocked. Refer to the pressure gauge to judge, eliminate, and re-process the system.
4, the evaporator or filter is dusty and scaled. The airflow becomes smaller and the system pressure and temperature are not constant. Clean the evaporator or filter.
5. Fluorine deficiency is also possible. In the absence of fluorine, the compressor discharge temperature will overheat, causing the overheating load protection switch to trip.
The circuit problem may be caused by the failure of the control circuit board; the temperature sensor is overloaded and the information is wrong; the power supply wiring is loose, the contact is poor, and the starting capacitor or the compressor starting coil is burned out.
Of course, for home maintenance novices, these maintenance knowledge can only solve the puzzle, and the professional maintenance personnel can really solve the problem.
Air conditioner failure is inevitable, but finding the cause of the problem can also relieve anxiety. Knowing the cause of the failure can prescribe the right medicine. It will be clearer and more convenient to communicate with maintenance personnel, and it will save a lot of trouble.
What to do if the air conditioner protection light is flashing and not cooling
Recent related posts
-
08/23/2020
What to do if the air conditioner protection light is flashing and not cooling
In the entire home repair industry, what can quickly arouse the attention of users is the previous TV repair, and the current air conditioning repair is also one.
-
08/23/2020
What should I do if the suction pressure of the refrigeration unit is too low 7 major failure causes to know
In the pharmaceutical, food and other industries, refrigeration units are common equipment, providing reliable protection for various low-temperature environments such as pharmaceuticals.
-
08/23/2020
What should I do before the air conditioner is turned on for the first time when I encounter the new crown virus in summer
In a live broadcast last night, Dr. Zhang Wenhong said that China’s epidemic prevention and control has done a good job. When people wear masks, the probability of contracting the new crown virus is very small. He said that when it is hot,
-
08/23/2020
What do the refrigeration system overcooling and overheating mean
The so-called "supercooling" is to pass the condensed saturated liquid through a certain device (such as a subcooler) and method (or measure) to recool it so that its temperature is lower than the saturation temperature under the condensation pressure, which is called supercooling .
-
08/23/2020
What are the specific operation methods for cold storage screw compressor maintenance
1. Disassembly method of screw compressor in cold storage Before the screw compressor of the cold storage must be overhauled, if possible, unload the slide valve to the "0" position, stop normally, and cut off the power supply.
-
08/23/2020
What are the common methods for refrigerant leak detection
Visual leak detection When oil stains are found somewhere in the system, this may be a leakage point.
-
08/23/2020
What are the advantages of water source heat pump compared with conventional air conditioning technology
Today, let us take a look at what are the advantages of water source heat pumps compared with conventional air conditioning technology?
-
08/23/2020
What are the advantages and disadvantages of the compressor of the screw type industrial chiller
At present, most of the compressors of screw-type industrial chillers choose Taiwan Hanbell or German Bitzer screw compressors, and they are increasingly recognized by the market for their remarkable advantages.
-
08/23/2020
Very strange Why does the air conditioning and refrigeration suddenly malfunction
Commonly used home appliances like air conditioners are very common in our lives, but in the process of use, large appliances such as air conditioners often have one or another failure.
-
08/23/2020
Various problems that may occur in central air conditioning
Many users will encounter various problems in the process of using central air-conditioning, such as noise, uncooled heat, power consumption, etc. Among them, nothing is more serious than air-conditioning leakage,