Voltage: 12 V DC
Nidec Fan D06K-12TS1
People who bought this item also viewed
Nidec Fan MGT8012VB-W38
Nidec Fan H92C24BS6AA7-53
Nidec Fan R80W12BS3B9-07T41
Nidec Fan B35129-51
SUNON Fan KD1204PKB2
Nidec Fan 3U80T12BS1A5-07Z04
Sanyo Denki Fan 9GE0412P3J04
Sanyo Denki Fan 109R0612H4D22
Tecumseh Compressor AJA2425AXD
COSEL Power Supply CBS100481R8-F1
CHINT Transformer JBK6-630
ABB Circuit Breaker 10096766
Eaton Contactor XTCG012B00B2
Danfoss Sight Glass SGH 12S 014-0283
Schneider Controller Module TSX3721DC
HONGFA Relay HFKW-012-1HW
BLACKGATE Capacitor 1000UF50V
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
AirTAC Air Cylinder ACP32X125S
AirTAC Air Cylinder TWH80X20S
Littelfuse Fuse OHEV020.SXC
Maxell Battery ER10/28
UniOhm Resistor 1210W2J0102T5E
Panasonic Air Conditioner SHE9KN1
Recent related posts
-
08/13/2020
How to judge the chilled water flow of the chiller
Generally speaking, when buying a chiller, you will have questions. I don't know how to judge the chilled water flow rate of the chiller? From what aspects should the chiller water flow be considered? Today, the editor of okmarts.com will share with you fPﰨ2 䀀 湠癐
-
08/30/2020
Observation on the evolution of the compressor industry
Some of the changes in the compressor market are like summer storms, such as price rises and falls, and sales volume. Some changes are like the drizzle in spring, moistening things silently.
-
08/05/2020
How does the air conditioner collect fluoride
1. Method: The method of collecting fluorine should be correct. Under the state of turning on and cooling, open the covers of the two connecting pipe valves of the outdoor unit with a wrench, use 5 hexagonal wrenches,
-
08/14/2020
Effective means to reduce the resistance of condenser heat transfer system
To ensure that the condenser has a higher heat transfer coefficient, it is necessary to reduce the resistance in the system. There are three ways to achieve this goal.
-
06/19/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
09/11/2020
Ways to reduce bearing noise
Ways to reduce bearing noise (1) Method of using chemical additives Adding certain chemical additives to the bearing lubricant can reduce bearing noise. For example, a low-noise grease containing noise-reducing additives produced by a factory in Tianjin can reduce bearing noise by 3.9-9.2dB from the original basis. , Suitable for use in miniature or small bearings.
-
07/28/2022
How to install a Vane Pump
The pump body is installed and fixed on a special foot rest with screws, and the foot rest is fixed on the base plate of the machine and equipment with bolts.
-
03/16/2021
How to maintain the servo motor driver?
In order to prolong the lifespanof the servo system, you should pay attention to the following aspects. For the operating environment of the system, the temperature, humidity, dust, vibration and input voltage need to be considered. Please regularly clean the ventilation system of the numerical control device. Always check whether the cooling fans on the numerical control device are working properly. It should be inspected and cleaned every six months or a quarter depending on the environment of the workshop.
-
08/14/2020
The difference between oil cooler and other coolers
An oil cooler is a heat exchanger that uses air to cool hot fluid. Like other coolers, rust scale will appear. The rust scale appears mainly because the cooling water contains a large amount of calcium, magnesium ions and acid carbonates.
-
12/15/2021
How Does Encoder Measure the Motor Position Accurately?
Encoder is a kind of equipment that can compile and convert signals or data into signals that can be used for communication, transmission and storage.