Nidec Fan D09T-12TS3
Type: Fan
Brand: Nidec
Voltage: 12 V DC
Type: Fan
Brand: Nidec
Type: Fan
Brand: Nidec
ROYAL Fan UT275DW-TP
Ebmpapst Fan G1G144-AF25-09
Nidec Fan D04R-24TH
Nidec Fan R80W12BS3B9-07T41
Nidec Fan U70R12MS6CB-52
Nidec Fan D07R-12T2S4
ORION Fan OD280-12MTB
SUNON Fan EG60070S1-C200-S9A
ORION Fan OD8025-12HB
ORION Fan OD4028-05MB
Mitsubishi Compressor ANB66FVQMT (15-120RPS)
Delta VFD Frequency Converter VFD750B43C
COSEL Power Supply AC9-HV2J2J-02
CHINT Transformer BKC-300
Schneider Contactor LC1K0601P7
PARKER Filter 937818
Danfoss Sight Glass SGN19S
Fanuc I/O Module A03B-0801-C111
NEC Relay UB2-12NUN
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Panasonic Servo Motor MHMA052P1G
TYCO Relay OUAZ-SS-105D,405
DINE Tool for Metal Cutting BT40-DHE6-90
Baumer Sensor OADM 20U2472/S14C
06/14/2020
Fault phenomenon: After a Mitsubishi SRC285cENF air conditioner is turned on, the indoor fan operates normally, and the indoor compressor does not rotate and cannot be cooled.
03/10/2021
Position feedforward gain: set the feedforward gain of the positioning loop. The larger the set value is, the smaller the position delay isand the larger the feedforward gain of the position loop is, the high-speed response of the control system will rise, but the position of the system is unstable and prone to oscillation. When high response characteristics are not required, this parameter is usually set to 0, indicating the range of 0 ~ 100%.
11/25/2021
What is HMI (Human Machine Interface)? This era is smart and full with information. We have already been placed in the age of smart technology and filled with all kinds of new devices and inventions every day.
05/26/2023
The compressor is the most important part of the refrigeration cycle of the air conditioner.
03/15/2022
In the refrigeration system of the cold storage, the refrigeration compressor is the core equipment.
09/03/2020
As the fourth most widely used energy source, compressed air is second only to traditional energy sources such as electric energy. As a necessary product for air compressors, compressed air is widely used in various fields of national production and life in my country.
10/16/2020
Insufficient compressor displacement has a great impact on the entire refrigeration system. If it is not repaired and handled in time, it may cause problems such as the cylinder, cylinder head rupture, and compressor water intake, which will destroy the entire refrigeration system cycle. It may even cause accidents such as compressor combustion and explosion. So what causes the insufficient displacement of Copeland compressor? Let's take a look.
06/29/2020
Analysis of the cause of excessive suction temperature of compressor The high suction temperature is mainly due to the increase of superheat of suction. Note that high suction temperature does not mean high suction pressure, because the suction is superheated steam. Under normal circumstances, the compressor cylinder head should be half cold and half hot. If the suction temperature is too high, the cylinder head will all heat up.
08/16/2020
1. Water source heat pump technology Water source heat pump technology is a low-temperature low-level thermal energy resource formed by using solar energy and geothermal energy absorbed from shallow water sources on the earth's surface
07/26/2021
Nowadays, cars have entered into our daily life. And the car is the most used traffic tool.