There is no price at present, you can Request a Quote
Attainable Vacuum
-66.7 kPa (-500 mmHg)
-667 mbar
-19.7 in. Hg
Free Air
Displacement
18 L/min
0.64 cfm
Rated Voltage 120 V AC 230 V AC
Power Consumption 34 W 35 W
Rated Frequency 60 Hz 50 Hz
Rated Performance 10,000 hours
Duty Cycle Continuous
Coil Insulation Class E or its equivalent and A for UL
Mounting Dimensions 85 (L) x 88 (W) mm
3 - 11/32" (L) x 3 - 15/32" (W)
nitto kohki Diaphragm Pump LINEAR VP0450
There is no price at present, you can Request a Quote
People who bought this item also viewed
SEKO Diaphragm Pump MS1A094C
GRACO Diaphragm Pump Husky515 D52911
ARO Diaphragm Pump 6661T3-3EB-C
VACUTRONICS Vacuum Pump DP-120V
Iwaki Magnet Pump EHN-C36VHMKR
KMP Water Pump 50X32-200
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Festo Air Cylinder AEVULQ-20-10-P-A
Sanyo Denki Fan 9RA0648G40011
BANDO Belt T2.5-305-27
Recent related posts
-
09/04/2020
How much do you know about piston compressors
The piston compressor is driven by a motor. The motor drives the crankshaft to make a circular motion through a coupling or gear and belt. The crankshaft drives the connecting rod (changes the direction of the force) for reciprocating swing motion
-
07/05/2022
8 Common Concerns about Magnet Pumps
Magnet pumps are very different from typical sealed pumps. Therefore, it is natural for people to have concerns. I narrowed the list to 8 questions that are commonly asked with regard to mag-drive pumps.
-
12/23/2022
What is an Erbium Doped Fiber Amplifier?
The erbium optical fiber amplifier (EDFA) is an optical amplifier made of optical fiber doped with erbium.
-
06/14/2020
New retail approaching maturity China's cold chain industry ushered in new opportunities for development
New retail approaching maturity Chinese cold chain industry ushered in new opportunities for development
-
09/09/2020
Comparison of screw type and piston type air compressor
Friends who are often exposed to air compressors should know the basic difference between piston air compressors and screw air compressors. They have obvious differences in structure, moving parts and operating parts, as well as consumption life and performance. , The following brings you some knowledge about the difference between the piston machine and the screw machine.
-
06/30/2020
Structural differences between three common compressors
Structural differences between three common compressors The three common structures of compressors are rotor compressors, scroll compressors and piston compressors. The structures of these three compressors are different. It is precisely because of their different structures that different functions exist.
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
01/05/2021
4 Common Refrigerator Compressor Problems You Need to Solve Fast
4 Common Refrigerator Compressor Problems You Need to Solve Fast A compressor is a vital part of the refrigerator, so it can be frustrating once breaks at inconvenient times. It’s not always easy to detect if the compressor has a problem, and it often ta 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦 ᮔDž༬皧嫦ིЀ
-
06/14/2020
Copeland compressors in the United States (notes)
Copeland compressors in the United States (notes) Heat pump type-excess liquid return test
-
06/14/2020
Is it necessary to install the fresh air system recommended during decoration Where are the people who have been eating ash for many years but are secretly happy this year
Is it necessary to install the fresh air system recommended during decoration Where are the people who have been eating ash for many years but are secretly happy this year Is it necessary for ordinary families to install fresh air system?