NORTHMAN Solenoid Valve HSRF-G06-1PN-1-L-A240-10
People who bought this item also viewed
Daikin Solenoid Valve LS-G02-2BP-20-EN
Honeywell Solenoid Valve VE4025A1002
MAC Solenoid Valve 44B-ABA-GDFA-1KT
Bristol Compressor H25A54QDBE
Keyence Sensor PZ-M62P
SMC Proportional Valve ITVX2030-04F3N4
Eaton Vickers Vane Pump 4525V-60A10-86DD22R
Casappa Gear Pump P14 D-G 28P2
Ingersoll Rand Filter 85565661
Danfoss Sight Glass SG5S
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
SHENYU Vane Pump HVP-20-FA2
Baldor Servo Motor BSM63A-275AA
Recent related posts
-
07/29/2022
Hydraulic Motor Types
A vane motor consists of a housing with an eccentric bore, in which runs a rotor with vanes in it that slide in and out.
-
08/10/2020
How to adjust the hydraulic balance of air conditioning system
In air conditioning water systems, hydraulic imbalance is the most common problem. Due to the hydraulic imbalance, the system flow distribution is unreasonable and the heat is unreasonable, which causes a waste of energy, or to solve this problem,
-
06/13/2020
Energy-saving screw compressor has a large development space.
Energy-saving screw compressor has a large development space. The machinery industry is still the most important market for air compressors. Energy-saving screw compressor has a large development space. The machinery industry is still the most important ﰸ2 䀀 ᅵ皥
-
06/20/2020
Common failure and analysis of centrifugal air compressor
Common failure and analysis of centrifugal air compressor 1. Abnormal vibration and noise: ① Misalignment ② The compressor rotor is unbalanced ③ The impeller is damaged ④ The bearing is abnormal ⑤ The coupling is faulty or unbalanced ⑥ The sealing ring is bad ⑦ The oil pressure and oil temperature are abnormal ⑧ There is dirt in the oil Clean, wear out the bearing ⑨ Surge ⑩ The stress of the gas pipeline is transmitted to the casing, which causes misalignment ⑪ There is a machine working near the compressor<img src="{{media url="Common_failure_and_analysis_of_centrifugal_air_compressor.jpg"}}" alt="" />
-
02/24/2020
What is the problem with the poor cooling effect of the air conditioner
In the hot summer, I believe that many people can not do without air conditioning, air conditioning can allow us to spend this summer in a cool environment. However, in the process of using air conditioners, I believe that many people have encountered a situation where the cooling effect of the air conditioner is not good, so why is the cooling effect of the air conditioner not good? What needs to be solved.
-
07/17/2020
Reasonably adjust the cold storage evaporator and defrost in time
Reasonably adjust the cold storage evaporator and defrost in time Generally speaking, every increase in the cold storage evaporation temperature can save energy Therefore, under the premise of satisfying the low refrigeration process of the product, the evaporation temperature can be increased as much as possible by adjusting the amount of liquid supplied. The thermal resistance of the frost layer is generally much larger than the thermal resistance of the steel pipe.
-
09/08/2020
Air compressor lubricant model the difference between No. 32 and No. 46 air compressor lubricants
Air compressor lubricants are generally No. 32 oil and No. 46 oil. No. 32 is a mineral type. The general service life is about 2000 hours and needs to be replaced. The operating temperature must be below 90 degrees to avoid carbon deposits.
-
08/13/2020
Maintenance and management methods of central air conditioning
Today, the editor of okmarts.com introduces to you several problems in the installation and maintenance of central air conditioning in the office, and proposes the following specific solutions, hoping to help you.
-
06/25/2020
The air conditioner suddenly stopped cooling.
1.The air conditioner remote control may not adjust the temperature. 2. It may be that the air conditioner has not been cleaned for too long, which causes dust to accumulate on the filter net, so that the cold air blocking the air conditioner cannot be blown out. 3. There may be leakage of freon in the air conditioner, resulting in too little freon, and the air conditioner is not cooled. 4. Energy saving is due to unstable voltage, which causes the air conditioner to not be cooled. 5. It may be that the number of air conditioners is insufficient, and the small number of horses is not used for cooling in a large area of the house.
-
09/08/2022
Permanent Magnet DC Motor: Types, Application, Selection Principle (1)
A <strong>permanent magnet DC motor</strong> (PMDC motor) is a type of DC motor that uses permanent magnets to create a magnetic field.