NORTHMAN Solenoid Valve SWH-G03-C3-D24-20-LS
People who bought this item also viewed
KOGANEI Solenoid Valve F10M12NJ
KOGANEI Solenoid Valve VA500AE1
Copeland Compressor ZR84KC-TFD-522
Saginomiya Expansion Valve UKV-40D08
KOMPASS Check Valve MCB-02-A
Peeimoger Electric Motor M-2DK6N-E18
KAWASAKI Piston Pump K5V160DPH
YUKEN Vane Pump S-PV2R13-31-66-F-RAAA
ENTEGRIS Filter WGPM0GGG2
Danfoss Sight Glass SG5
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Siemens Sensor 3RG4012-0GB33-1AF0
Omron Light Curtain F3SN-A0502P25SS-S
CAT Piston Pump 1541C
TCS Oil Seal TC 35*75*10
Recent related posts
-
07/14/2020
Analysis on energy saving and consumption reduction of compressed air system
Analysis on energy saving and consumption reduction of compressed air system Compressed air is widely used in the industrial field due to its safety, environmental protection, good adjustment performance, convenient transmission, convenient centralized management and application, and good working environment applicability.
-
08/24/2022
Choose the Right Electric Valve Actuator
The actuator is an indispensable and important part of automatic control system. Its function is to accept the control signal sent by the controller and change the size of the controlled medium
-
07/29/2020
Adding fluoride to the air conditioner is tricky, don't be fooled!
remind<br></br> In the hot weather, many citizens have begun to use air conditioners to remind everyone to be careful not to be fooled by unnecessary "air conditioner filling
-
06/13/2020
An explosion in a building in Haikou caused 1 death and 10 injuries. The initial judgment was that the central air conditioner was leaking
An explosion in a building in Haikou caused 1 death and 10 injuries. The initial judgment was that the central air conditioner was leaking According to the news released by Haikou, after an on-site investigation by experts, it was preliminarily judged th 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦 ᮔDž༬皧嫦ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱
-
06/19/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
03/20/2024
DC Servo Motor: Working Principle, Pros &Cons, Speed Adjustment Methods and Application
DC servo motor is a high-precision, high-speed, high-reliability motor that is widely used in various industrial fields. It controls the motor speed and position through a closed-loop control system, which can achieve extremely high motion control accuracy.
-
06/26/2020
Compressor starting circuit diagram
[Introduction] Compressor startup circuit diagram. Refrigerators, air conditioners and other appliances, the compressor is driven by a single-phase induction motor. When starting, the induction motor must overcome both its own inertia and high-pressure refrigeration
-
06/13/2020
Analysis and solution of the three reasons for the high temperature of the exhaust of the compressor dryer
Analysis and solution of the three reasons for the high temperature of the exhaust of the compressor dryer
-
06/13/2020
Problems and case analysis of electronic expansion valve and four-way valve
Problems and case analysis of electronic expansion valve and four-way valve 1. The problem of electronic expansion valve 1 Identify the quality of electronic expansion valve: Step one (see): Whether the wiring is plugged in place and whether the c 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦 ᮔDž༬皧嫦ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿먲僧ᐱ㥲ᐲ�僬㣢ᐲ ᠾ 랖僧զ 識 �僬㣢ᐲ 臆S㥲ᐲ ᬄğ 識 理艏S杴 識杴 㥲ᐲ
-
09/05/2020
What role does air compressor play in washing equipment and how to use it safely
Generally, you need to buy an air compressor to open a laundry room, so how big an air compressor should be configured in a general laundry room? This is the concern of the owner of the investment laundry room