Connection Type:T: Threaded Connection / F: Flange Connection
Rated Flow:315L/min
OMAX Overflow Valve PCV-10F
People who bought this item also viewed
DUPLOMATIC Overflow Valve MZD3-50
TOYOOKI Overflow Valve HRU3ー80G*K(D)ー06
FESTO Check Valve GRLA-3/8-QS-8-RS-D
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
KSK Oil SealTC(NBR)18X31X7
HGK Tool for Metal Cutting 55° 16x250
SUNX Sensor FX-301B
HAZE Battery HZY2-300
SOG Oil Seal TB72*120*12
Recent related posts
-
09/23/2020
Application of DCS system in anti-surge control system of air separation compressor
Keywords: DCS system, air separation compressor, anti-surge control system Preface The 6000m3/h air separation plant of Xilin Iron and Steel Company was completed in May 2001 by Hangzhou Oxygen Concentrator Group Company. The factory design was designed by Beijing Iron and Steel Design Institute. It was successfully put into operation on September 2, 2001, and it took more than half a year to run. It shows that the unit is operating stably, and all indicators have reached or exceeded the design value. The entire control system uses Honeywell’s TDC3000 and two GUS stations.
-
08/16/2020
Why is the temperature too low after the cold storage is installed
After the cold storage is built, the first thing should be tested, so that we can know whether there will be problems after the cold storage is installed. Such a problem needs to be considered in the initial stage of the general cold storage installation.
-
08/23/2020
What kind of equipment is suitable for high and low pressure refrigerant charging method
There are generally two types of refrigerant charging methods: low-pressure charging and high-pressure charging. The advantage of the low pressure charging method is that it is easier to control the amount of refrigerant charged,
-
06/14/2020
The principle, installation and use of the bypass valve of the heater of the cold dryer Composition and principle of "heater bypass"
The principle, installation and use of the bypass valve of the heater of the cold dryer Composition and principle of "heater bypass" The energy regulation of the system is generally composed of the following ways: Compressor parallel-multi-stage contro 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦 ᮔDž༬皧嫦ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ
-
07/14/2020
Compressor operation requirements
Compressor operation requirements The first load operation of the compressor is carried out after the empty vehicle operation and purging are completed. The compressor should be operated according to the following requirements:
-
09/15/2020
Adjustment of main machine clearance of twin screw compressor
I repaired a main engine with locked rotor in the early stage. It is an EP200 model produced by Ingersoll Rand in 1997. Before I repaired it, Ingersoll Rand itself could not repair it. Because the main engine was severely deformed and the rotor and cavity Severe body adhesion.
-
06/14/2020
Commercial Refrigeration Compressor Market to Surge at 221.7 Million units by 2026; Introduction of Advanced Technologies to promote Growth, Says Fortune Business Insights™
Key Companies Covered in Commercial Refrigeration Compressor Market Research Report Are Carrier Corporation, Daikin Industries Ltd., Johnson Controls Pvt. Ltd., Mitsubishi Electric, Bitzer, Emerson Climate Technologies, Ingersoll Rand Inc., Rechi Precisio 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦
-
08/30/2022
How to Calculate the Breaking Capacity?
The breaking capacity of the circuit breaker is an important indicator of the circuit breaker, which refers to the ability of the circuit breaker to safely cut off the fault current. There are 36KA, 50KA and other specifications.
-
09/19/2022
Top Circuit Breaker Brands
Circuit breakers are switching appliances that provide circuit overload and short-circuit protection.
-
08/14/2020
The difference between independent and non-independent refrigeration units
The cold storage is a special place dedicated to refrigeration, and now it is mainly used to keep food fresh. With the increasing requirements for the freshness of food, the use of cold storage is gradually increasing.