Accuracy: ±2% full scale (±5% FS on FL3607/3707 and FL3845/3945 models)
Repeatability: ±0.25% full scale
Connections: 1/8 FNPT, horizontal
Flow Tube: Borosilicate glass
End Fittings: Anodized aluminum or 316 SS
Side Panels: Aluminum
Valve Orifice: Polyacetal for aluminum models, Kel-F in 316 SS models
O-Rings and Packings: Buna in aluminum models, FKM in 316 SS models
Packings: FKM
Float Stops: PTFE
Max Temperature: 121°C (250°F)
Max Pressure: 200 psig (13.8 bar)
Omega Flowmeter FL-3903ST
People who bought this item also viewed
YOKOGAWA Flowmeter AXFC-4-L015/CH
KES Level Meter CLT-1-B1-C0-40-110
B&C Turbidity Meter TU8325
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
PARKER Filter G03307
Siemens Circuit Breaker 5SN4106-6CN
Recent related posts
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
11/03/2023
How to Test Your Radiator Fan: A Step-by-Step Guide
A properly functioning radiator fan is crucial for maintaining the optimal temperature of your vehicle's engine.
-
09/27/2022
What is the Difference Between Piston and Plunger Pumps
Plunger and piston pumps are very similar in construction and both are reciprocating positive displacement pumps.
-
06/16/2020
Danfoss expands portfolio of oil-free compressors with new TGS490
Danfoss expands portfolio of oil-free compressors with new TGS490 Danfoss, the world’s leading manufacturer of oil-free compressor technology, has expanded the oil free compressor portfolio with the introduction of the TGS490.
-
09/05/2020
What is a gas source system What are its components
A system composed of equipment that generates, processes, and stores compressed air is called an air source system. A typical air source system usually consists of the following parts: air compressor,
-
04/01/2024
Top 9 Robot Servo Motor Manufacturers Worldwide
The booming development of the industrial robot industry has also led to the development of related upstream industries.
-
08/11/2020
Several common causes of compressor bearing damage
There are many important precision parts in first-class compressors, and the most worn part during regular operation is the bearing, so the bearing is one of the parts that need frequent maintenance and replacement.
-
08/29/2020
How to achieve zero failure of enterprise compressor equipment
How to achieve zero failure of enterprise compressor equipment
-
01/07/2021
Cold storage installation
Cold storage installation 1. Precautions for testing after cold storage installation 1. Start the refrigeration compressor and check whether it is normal. The rotation direction of the open compressor is correct. When the compressor is started, it sho 器2 䀀 ᅵ皥 䖒皦즠Ʋ奌ི 㲈Ʋ 䌁皦 ᮔDž༬皧奖ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿먲僧ᐱ㥲ᐲ�僬㣢ᐲ ᠾ 랖僧ז 識 �僬㣢ᐲ 臆S㥲ᐲ ᬄğ 識 理艏S杴 識杴 㥲ᐲ
-
09/10/2020
Types and characteristics of air compressors and their application choices
Air compressor (English: aircompressor) is the main body of the air source device. It is a device that converts the mechanical energy of the prime mover (usually an electric motor) into gas pressure energy, and is a pressure generating device for compressed air.