Repeatability: ±1%
Flow Measuring Range: 0.4 - 560 lpm (0.1 - 150 gpm)
Maximum Operating Pressure:
Aluminum and brass monitors: 3500 psig (240 Bar)
Stainless steel monitors: 6000 psig (410 Bar) up to 116°C (240°F)
Maximum Operating Temperature:
Standard Models: 116°C (240°F)
High Temp (-HT) Models: 204°C (400°F) max
Ultra High Temp (-UHT) Models: 316°C (600°F) max
Pressure Differential: download spec sheet for pressure drop graphs
Standard Calibration Fluids:
Oil monitors: DTE 25 @ 43°C (110°F), 0.873 sg
Water monitors: tap water @ 21°C (70°F), 1.0 sg
Maximum Particle Size: 76 microns
Relay (Optional): 1 or 2 form “C” relays, rated 10 A @ 125 or 250 Vac or 0.25 A @ 250 Vdc
Mechanical Life: >107 cycles
Analog Output (Optional): Supply voltage 12 to 35 Vdc, field selectable for 0 to 5 Vdc (100 W minimum load), 0 to 2000 Hz square-wave pulse or 4 to 20 mA; Rmax = 50 (Vs-12). Vs = supply voltage DC
Installation Dimensions:
1/4 and 1/2 NPT Sizes: 1-7/8 OD x 6.6" length
3/4 and 1 NPT Sizes: 2-3/8 OD x 7.2" length
1-1/4 and 1-1/2 NPT Sizes: 3-1/2 OD x 10.1" length
Omega Flowmeter FLMH-3430
People who bought this item also viewed
YOKOGAWA Flowmeter AXFC-4-L010/CH
Zhengrun Level Meter ZWP-L61-K-B
HANNA Turbidity Meter HI847492
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
PIZZATO Switch FD 1102-M2
Delta Servo Motor ECMA-E11310FS
SUNX Sensor HL-C2C
Baumer Sensor UNDK 10U6914/KS35A
Agilent Keysight Power Supply E3631A
Recent related posts
-
07/31/2020
The weather is getting colder and you need to pay attention to these hidden dangers when using air conditioners!
Soon after the summer ends, it feels like a direct transition to winter. The weather began to cool down, and many families began to use air-conditioning and other heating equipment one after another.
-
07/01/2020
Precautions for the use of screw air compressor oil
Precautions for the use of screw air compressor oil Precautions for the use of screw air compressor oil: It is forbidden to mix air compressor oils of different brands and grades. The old oil must be drained when replacing. It is strictly forbidden to add or filter and reuse. Because although the color of the compressor oil does not change on the surface, the consumption of additives may have exceeded the limit.
-
06/14/2020
Refrigeration Compressor Market Research Report 2020: Key Players, Applications, Drivers, Trends And Forecast To 2026
A report, added to the extensive database of verified Market Research titled Refrigeration Compressor Market 2020 by Manufacturer, Region, Type and Application, Forecast up to 2026,
-
02/08/2022
Why Refrigeration System Clogged
The blockages in the refrigeration system include ice, dust, oil and welding blockage, etc.
-
07/02/2020
Baifuma Compressor How to define the stability of the compressor
Baifuma Compressor How to define the stability of the compressor Baifuma compressors have many characteristics, such as pressure ratio, efficiency, mass flow and additional energy. Another important feature is stability. Many people will ignore the stability of the compressor, which is a very bad thing.
-
06/28/2020
One article to understand what is a piston compressor
One article to understand what is a piston compressor Piston compressor is a compressor that relies on live cold reciprocating motion to pressurize gas and deliver gas. It belongs to positive displacement compressor, also known as "reciprocating piston compressor" or "reciprocating compressor".
-
09/14/2020
Analysis of the consequences of refrigerant liquid entering the compressor
When the refrigerant liquid entering the evaporator is too much or the evaporation pressure is too low, the cold The medium liquid will be sucked into the compressor. Since the refrigerant liquid is incompressible,
-
11/15/2021
Best Suggestions for Encoder Wiring
Encoder is a kind of measuring device, which mainly converts pulse signal into data signal for people to read. Users choose different types of encoders with different application values.
-
08/19/2020
Why do industrial chillers need to replace high-quality antifreeze regularly
When the industrial chiller is running, there are high requirements for the use of antifreeze. Ordinary equipment cannot use high concentration antifreeze. If the concentration of antifreeze is high, it takes a long time to warm up before operating the equipment.
-
08/26/2023
How Do I Know If I Have a Heat Pump or an AC? A Comprehensive Guide
If you're a homeowner, you may be wondering whether you have a heat pump or an air conditioner (AC) installed in your home. Both systems provide cooling during the summer months, but they work in different ways.