-29 to 116°C (-20 to 240°F)
Maximum Pressure: 3500 psig
(liquids); 1000 psig (gases)
Power Requirement:
0 to 5 Vdc Output: 10 to 30 Vdc @
0.75 W maximum
0 to 10 Vdc Output: 12 to 30 Vdc @
0.75 W maximum
4 to 20 mA Output: Loop-powered,
30 Vdc maximum
Power Consumption: 25 mA maximum
Circuit Protection:
Reverse polarity and current limit
Repeatability: ±0.5%
Non-Linearity: ±0.05%
Isolation: Inherently isolated from
the piping system
Display: Fixed or toggle modes of
operation for rate and totalizer display.
8-digit, 0.70" high numeric display
for rate and total 8-digit 0.35" high
alphanumeric display for units
and setup
Response Time: 1.0 sec
Temperature Drift:
0.05% of span per °C maximum
Analog Outputs:
4 to 20 mA into 1KΩ maximum
0 to 5 Vdc into 10KΩ minimum
0 to 10 Vdc into 10KΩ minimum
User Connections:
15' pig-tail (standard)
Transmission Distance:
4 to 20 mA limited by cable resistance
0 to 5 Vdc 300 m (1000') maximum
0 to 10 Vdc 300 m (1000') maximum
Omega Flowmeter FLR7320D
People who bought this item also viewed
YOKOGAWA Flowmeter AXFC-4-L015/CH
MAC3 Level Meter MAC3-20
HANNA Turbidity Meter HI98292G
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
ITECH Power Supply IT6302
Contrinex Sensor LLS-3031-202
Recent related posts
-
08/11/2020
Installation specification for mainframe of refrigeration unit
he closer the main unit of the refrigeration unit is to the evaporator, the better it is easy to maintain and has good heat dissipation. If it is moved outside, it needs to install a canopy.
-
06/14/2023
6 Ways to Quiet Your Noisy Refrigerator Compressor
A noisy refrigerator compressor can be a source of irritation for homeowners, especially if the appliance is located in a common area of the home.
-
09/11/2020
Oil bath air filter zksg
In the working environment with high dust concentration in the air, the dust removal filter device used in general air compressors is mostly screen-type secondary dust removal paper and fiber material filtration.
-
07/02/2020
In the post-new crown era, what are the market opportunities for refrigeration companies
In the post-new crown era, what are the market opportunities for refrigeration companies When we thought that the fear and anxiety caused by the new crown epidemic were going away, when we set up stalls in full swing to prepare for the development of the night economy, the small-scale counterattack of the new epidemic in Beijing made the originally slightly relaxed nerves tense again.
-
06/22/2020
What's wrong with air conditioning and cooling
1.The air conditioner lacks freon. Under such circumstances, the air conditioner cooling effect will be poor. 2. If there is a lot of dust and dirt in the filter, it will affect the heat dissipation effect, which will affect the cooling. 3. The outdoor temperature is too high, and it is difficult to lower the temperature by turning on the air conditioner at home. 4. Voltage problem, the power supply voltage of normal air conditioner is 220V, but if it is lower than 220V, the cooling effect will be greatly affected. Summer is coming soon, and the weather is getting hotter. But if the cooling effect of the air conditioner is not good after turning on, what is going on? Is there any good solution? <img src="{{media url="magefan_blog/What_s_wrong_with_air_conditioning_and_cooling.jpg"}}" alt="" />
-
04/05/2024
Analysis and Solutions to AC Servo Motor Vibration Faults
AC servo motors are used in closed environments and are usually not easily damaged. But if the AC servo motor has vibration failure, what is the reason?
-
07/01/2020
Share the characteristics of ZR series Copeland compressors
Share the characteristics of ZR series Copeland compressors There are many types of compressors, and this is what everyone knows. One of them is the Copeland compressor. Due to the advancement of technology, the Copeland compressor has begun to have various series and styles. The function of each series and style is different. Copeland Compressor
-
05/24/2023
Why is My AC Compressor Not Turning on and What to Do?
The air conditioner compressor (AC compressor) is generally installed in the outdoor unit. When the air conditioner is running, the compressor sucks the refrigerant from the low-pressure area
-
09/08/2020
The characteristics of the main shaft of the frequency conversion screw air compressor
The main core of the equipment operation of the rod host during the operation of the variable frequency screw air compressor. Without the rod host equipment, the equipment cannot operate normally. The following is an explanation of the characteristics of the rod host used in the air compressor equipment:
-
08/19/2020
How to clean air conditioner filter
The use of air conditioners is not unfamiliar to everyone. With the continuous improvement of people’s living standards, air conditioners have been popularized in every family, and the