0IK1GN-C
0IK1GNC
DISCONTINUED BY MANUFACTURER
INDUCTION MOTOR
200 V
50/60 HZ
0.07 AMP
0.8/1 WATTS
1000/1200 R/MIN
Oriental Motor Vexta Reduction Drive Gearbox Speed Reducer OIK1GN-C
People who bought this item also viewed
Oriental Gearbox 5GVR7.5B
Oriental Gearbox GFV5G15S
Yaskawa Servo Motor SGMGH-09DCA2H
POROVIN Planetary Reducer TD090L1
Danfoss Electric Motor VMP 200
MITSUBOSHI Belt B-38
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
HIGH-TECH Vane Pump PVL2-65-F-2R-U
IFM Sensor IM501A
DANHI Air Cylinder SCTM16-10
WINMOST Solenoid Valve WD-G02-B3B-A1-N
Recent related posts
-
06/14/2020
How to judge the quality of single-phase and three-phase refrigeration compressors
A compressor is a driven fluid machine that raises low-pressure gas to high-pressure gas, and is the heart of a refrigeration system. Then, after-sales maintenance sometimes doubts that the compressor is malfunctioning, how to check and judge at this time 器2 䀀 ᅵ皥 䖒皦즠Ʋ煔क़ 㲈Ʋ 䌁皦 ᮔDž༬皧煞क़Ѐ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
09/03/2020
German dairy giant highly praises Ultima compressor
ULTIMA new generation innovative oil-free compressor German dairy giant highly praises Ultima compressor Ultima works perfectly, a compressor that satisfies all your fantasies
-
06/16/2023
How to Reset a Refrigerator Compressor: a Step-by-Step Guide
If your refrigerator is not cooling properly or is making strange noises, it may be time to reset the compressor.
-
06/30/2020
What happens if the refrigerant recovery time of the air-conditioning compressor is too long
What happens if the refrigerant recovery time of the air-conditioning compressor is too long At ordinary times, we will need to simply disassemble and assemble the compressor due to certain circumstances. However, if you do not pay attention to certain matters when disassembling, it will cause the compressor to be directly damaged, so you will not be able to compensate for it.
-
09/05/2020
What are the energy saving methods for air compressor systems
Facing the challenges of global climate change and environmental ecology, countries and industries in the world are actively taking action to find a way for energy-saving development.
-
07/02/2020
How important is the air conditioning compressor for air conditioning
How important is the air conditioning compressor for air conditioning As the earth we live in enters summer, the summer in many places is uncomfortably hot, so a good summer cool companion to accompany them is-air conditioning. Air conditioning has become a good weapon for us to spend the summer.
-
09/11/2023
Exploring the Different Types of Heat Pumps: A Comprehensive Guide
Heat pumps are an excellent source of heating and cooling for homes and businesses, offering energy efficiency, comfort, and convenience. They are available in a variety of types, each with their own advantages and disadvantages.
-
05/30/2022
How Do I Test the Power Supply in My Computer?
Testing a power supply is an important step when troubleshooting many issues, most obviously when your computer is having trouble starting.
-
09/08/2020
The characteristics of the main shaft of the frequency conversion screw air compressor
The main core of the equipment operation of the rod host during the operation of the variable frequency screw air compressor. Without the rod host equipment, the equipment cannot operate normally. The following is an explanation of the characteristics of the rod host used in the air compressor equipment: