1a 8A, 1a1b/2a 5A
Small polarized power relays
Contact arrangement:1 Form A 1 Form B
Panasonic Relay DSP1-DC9V-F
People who bought this item also viewed
TOGAMI Relay TJ-125-3F
JEL Relay S1C-225WDV
PARKER Relay SCPSD-400-14-27
CHINT Transformer TDR-20
GE Circuit Breaker FG400 3P 400A
Siemens Contactor 3RA2328-8XB30-2BB4
PHOENIX Surge Protection Device LIT 2-24
Littelfuse Fuse BLF6.25
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
OMEGA Pressure Gauge DPGM409S15-035BG
Nidec Fan B34605-57
PARKER Filter PS702P
ESBAND Belt PU11 1470×22×3.0
CHELIC Solenoid Valve SMB5100-C4
NMB-MAT Fan 4712KL-04W-B19
Recent related posts
-
09/11/2020
Electric valves have the advantages of easy assembly and low failure rate, becoming the mainstream of the market
In terms of operating efficiency and saving energy consumption, the use of automatic control valves is an indispensable part. The manual valves and pneumatic valves commonly used in traditional industries are not as good as electric valves in terms of installation cost and efficiency.
-
07/23/2020
Analysis of common failure causes of hermetic refrigeration compressors
1. How to identify the 3 terminals on the casing of a hermetic compressor?<br></br> The resistance between running terminal (R), starting terminal (S), common terminal (C), RS is greater than the resistance between SC and RC. The resistance between RS is equal to the resistance between SC and the resistance between RC.<br></br>
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
07/02/2020
Several reasons why the American Taikang compressor meets China's national conditions
Several reasons why the American Taikang compressor meets China's national conditions In this era, as the Chinese people's vision is getting higher and higher, even imports must meet a condition in order to gain a long-term foothold in the Chinese market. This prerequisite is in line with China's national conditions.
-
06/01/2022
6 Common Types of Power Supply?
As we mentioned before, power supply can be divided into DC power supply and AC power supply. What are the specific types of power supply? Let me introduce them to you.
-
09/15/2020
Technical characteristics of silent oil-free air compressor for laboratory
The silent oil-free air compressor used in the laboratory is specially matched with the precision instruments of the laboratory, which can provide pure air source and stable pressure. main feature
-
06/14/2020
Do you know the two methods of evacuating the refrigeration system?
Do you know the two methods of evacuating the refrigeration system? Vacuuming is an indispensable important process before charging refrigerant in the production or maintenance of refrigeration equipment. The process of removing the non-condensable gas a 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦 ᮔDž༬皧嫦ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥
-
09/19/2022
How Does a Hydraulic Pump Work?
In modern construction machinery, hydraulic working devices are basically inseparable.
-
08/20/2020
Trouble phenomenon the air conditioner is not cooling, the outdoor unit starts and stops frequently
When the air conditioner is frequently used in summer, many friends will encounter this problem, that is, the outdoor unit of the air conditioner frequently starts and stops, but the indoor unit is not cooled.
-
08/19/2022
Types of Linear Motors
linear motor as the name suggests, is a motor that produces linear motion. The working principle of linear motor