Output Ratings
Output 1: 0 to 6 V, 0 to 5 A
Output 2: 0 to +25 V, 0 to 1 A
Output 3: 0 to -25 V, 0 to 1 A
Programming Accuracy at 25 degree Celsius +/- 5 degree Celsius
Voltage: 0.05% + 20 mV, 0.05% + 20 mV, 0.1% + 5 mV
+ Current: 0.15% + 4 mA, 0.15% + 4 mA, 0.2% + 10 mA
Ripple & Noise (20 Hz to 20 MHz)
Normal Mode Voltage:
<350 microVrms/ 2 mV p-p, <350 microV rms/2 mV p-p, <350 microV rms/2 mV p-p
Normal-mode current: <500 microA rms, <500 microA rms, <2 mA rms
Readback Accuracy at 25 degree Celsius +/- 5 degree Celsius
Voltage: 0.05% + 10 mV, 0.05% + 10 mV, 0.1% + 5 mV
Current: 0.15% + 4 mA, 0.15% + 4 mA, 0.2% + 10 mA
Agilent Keysight Power Supply E3631A
People who bought this item also viewed
ZIPPY Power Supply P2F-5400V
Panasonic Servo Motor MDME102GCDM
Yaskawa Servo Drive SGDV-780A15A
Siemens Transmitter 7MF4034-1BA00-1BC1
Siemens PLC 6ES7322-1BH00-0AA0
SuperRed Fan CHB6005DB
Crouzet Electric Motor 82344854
LR-LINK NIC Card LRES3007PF-OCP 4-port
Beckhoff Module EL2964
Sonnenschein Battery A512/115 A
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Mitsubishi Servo Motor HC-KFS13B
Schneider Sensor XS118BJPAM12
SCHNEEBERGER Linear Guideway BMB30-G0V1
VARTA Battery H8 90 L T2 H
Eltra Encoder ER58CM1024Z8/24L10X6JR
METTLER TOLEDO Conductivity Meter S3-Meter
Recent related posts
-
02/28/2024
A Comprehensive Guide to RV Refrigerator Fans: Basics, Types, Functions & Installation
Recreational vehicles (RVs) are synonymous with adventure and freedom, allowing enthusiasts to explore the open road without sacrificing the comforts of home. Among the crucial components of an RV is the refrigerator.
-
08/10/2020
How to adjust the hydraulic balance of air conditioning system
In air conditioning water systems, hydraulic imbalance is the most common problem. Due to the hydraulic imbalance, the system flow distribution is unreasonable and the heat is unreasonable, which causes a waste of energy, or to solve this problem,
-
12/04/2023
Notebook Cooling: Function Analysis of Thermal Grease, Heat Pipe and Cooling Fins
In the cooling module of the notebook, the three most critical elements are the heat pipe, the cooling fan and the cooling fins, and there are also elements used to improve the contact area and heat transfer efficiency between them.
-
06/14/2020
Precautions for the use of central air conditioner thermostat
The temperature controller is an electric switch device that controls the temperature of the air-conditioned room.
-
09/16/2020
Analysis of Frequency Conversion Technology in the Application of Air Compressor System
1. Operation principle and analysis of air compressor As far as okmarts.com is concerned, the main equipment currently being renovated is basically a traditional screw air compressor. The air compressor is a load with a large moment of inertia.
-
06/25/2020
Advantages and disadvantages of Hitachi central air conditioning
At present, the central air-conditioning of the refrigerant system is still the best done by Japanese brands. When it comes to Japanese central air-conditioning, one has to say that Hitachi, one of the Japanese air-conditioning BOSS, is a well-known international central air-conditioning brand. Most air conditioners now use scroll compressors as the core of power, and the world’s first scroll machine for air conditioning was manufactured by Hitachi in 1983.
-
09/09/2020
Basic requirements for choosing gas storage tanks
First of all, choose the products of large enterprises and well-known brands of gas storage tanks. The products of these gas storage tank companies not only strictly implement the GB150-98 "Steel Pressure Gas Storage Tank Container" standard, but also form their own corporate standards.
-
06/14/2020
Cause Analysis of Refrigeration Compressor
Cause Analysis of Refrigeration Compressor Cannot Start or Stop Quickly After Start 1) First check the main circuit. Whether the power supply has power, whether the voltage is normal,
-
09/07/2020
The reason why permanent magnet compressor replaces electric tiger
Energy conservation is the theme of the development of this era. In this era, we will regard energy conservation as a reference value no matter what products we buy. In the past two years,
-
09/06/2020
Main properties of permanent magnet materials commonly used in motors
Permanent magnet materials commonly used in motors include sintered magnets and bonded magnets. The main types are AlNiCo, ferrite, samarium cobalt and neodymium iron boron.