Pro-face HMI Touch Screen 15-INCH Rating:AC100-240V 50/60Hz 0.75-0.44A
FP3710-T42-U(PFXFP3710T2AU)
Display Type |
TFT Color LCD |
Display Size |
15" |
Resolution |
1,024 x 768 pixels (XGA) |
Dot pitch |
W0.297 x H0.297 mm [W0.01 x H0.01 in.] |
Effective Display Area |
W304.1 x H228.1 mm [W11.97 x H8.98 in.] |
Display Colors |
16,777,216 Colors |
Backlight |
When Rev.5 is marked: LED backlight (The backlight cannot be replaced by the user. The unit must be sent back for backlight replacement.), When Rev.5 is NOT marked: CCFL (The backlight can be replaced by the user.)*1 |
Brightness Control |
Available*2 |
Contrast Control |
Available |
Backlight Service Life |
50,000 hrs. or more (continuous operation at 25 °C before backlight brightness decreases to 50% or backlight starts to blink) |
Touch Panel Type |
Resistive Film (analog) |
Touch Panel Resolution |
1,024 x 1,024 |
Touch Panel Service Life |
1,000,000 times or more |
Touch Panel Interface |
RS-232C or USB (USB2.0, TYPE-B) |
USB (TYPE-A) |
Conforms to USB2.0 (TYPE-A) x 1, Power Supply Voltage: DC 5 V ±5 %, Output Current: 500 mA or less, Communication Distance: 5 m or less |
Video |
Analog RGB input connector: mini D-Sub15 (socket) x 1,<br> |
1.About the differences in a CCFL model and a LED model.
2.Specified on OSD setting.
3.- FPs which have a mark in hardware revision "2" support DVI Hot Plug Detect function.
- DVI-D Cable FP-DV01-100(10m) can be used with PL-3000B (Revision B or later) and PS2000B.
- PS4000 Series can be connected with FP unit's revision "2" or later and DVI-D Cable FP-DV01-50(5m).
- For connection with the FP which is not marked on Rev. "2", connection may not be made with a DVI-D interface of the FP.
In that case, use an analog RGB interface of the FP.
- We will recommend the resolution of PS4000, PL3000B, PS2000B and PC/AT compatible to change to the maximum display resolution of FP additionally.
Rated Input Voltage |
AC 100 to 240V |
Input Voltage Limits |
AC 85 to 264V |
Rated Frequency |
50/60 Hz |
Rated Frequency Range |
40 to 72 Hz |
Allowable Voltage Drop |
1 cycle or less(Voltage drop interval must be 1 second or more.) |
Power Consumption |
AC 100 V: 110 VA or less, AC 240 V: 168 VA or less |
In-Rush Current |
60 A or less |
Voltage Endurance |
AC 1,500 V 20 mA for 1 min (between charging and FG terminals) |
Insulation Resistance |
DC 500 V, 10 MΩ or more (between charging and FG terminals) |
Surrounding Air Temperature |
0 to 50 °C (32 to 122 °F) |
Storage Temperature |
-20 to 60 °C (-4 to 140 °F) |
Ambient Humidity |
10 to 90 % RH (Wet bulb temperature: 39 °C or less - no condensation.) |
Storage Humidity |
10 to 90 % RH (Wet bulb temperature: 39 °C or less - no condensation.) |
Dust |
0.1 mg/m³ or less (non-conductive levels) |
Pollution Degree |
For use in Pollution Degree 2 environment |
Atmosphere |
Free of corrosive gases |
Air Pressure (altitude range) |
800 to 1,114 hPa (2,000 m [6,561ft.] above sea level or less) |
Vibration Resistance |
IEC/EN61131-2 compliant, 5 to 9 Hz Single amplitude 3.5 mm [0.14 in.], 9 to 150 Hz Fixed acceleration: 9.8 m/s², X, Y, Z directions for 10 cycles (100 min) |
Concussion Resistance |
IEC/EN61131-2 compliant, 147 m/s², X, Y, Z directions for 3 times |
Noise Immunity |
Noise Voltage: 1,500 Vp-p, Pulse Duration: 1 µs, Rise Time: 1 ns, (via noise simulator) |
Electrostatic Discharge Immunity |
Contact Discharge Method: 6 kV (IEC/EN61000-4-2 Level 3) |
Grounding |
Protective grounding: Grounding resistance of 100 Ω, 2 mm² or thicker wire, or your country's applicable standard. (Same for FG and SG terminals) |
Structure |
Equivalent to IP65f (on the front panel when properly installed in an enclosure)*4 |
Installation Configuration |
Embedded panel |
Cooling Method |
Natural air circulation |
Weight Approx. |
7 kg [15.4 lb] or less (display unit only) |
External Dimensions |
W395 x H294 x D60 mm [W15.55 x H11.57 x D2.36 in.] |
Panel Cut Dimensions |
W383.5 x H282.5 mm [W15.1 x H11.12 in.], Panel thickness area: 1.6 to 10 mm [0.06 to 0.39 in.]*5 |
4.The front face of the FP unit, installed in a solid panel, has been tested using conditions equivalent to the standards shown in the specification. Even though the FP unit's level of resistance is equivalent to these standards, oils that should have no effect on the FP can possibly harm the unit. This can occur in areas where either vaporized oils are present, or where low viscosity cutting oils are allowed to adhere to the unit for long periods of time. If the FP's front face protection sheet becomes peeled off, these conditions can lead to the ingress of oil into the FP and separate protection measures are suggested., Also, if non-approved oils are present, it may cause deformation or corrosion of the front panel's plastic cover. Therefore, prior to installing the FP be sure to confirm the type of conditions that will be present in the FP's operating environment., If the installation gasket is used for a long period of time, or if the unit and its gasket are removed from the panel, the original level of the protection cannot be guaranteed. To maintain the original protection level, be sure to replace the installation gasket regularly.
5.Regarding dimensional tolerance, everything +1/-0 mm [+0.04/-0 in.] and R in angle are below R3 [R0.12 in.].
You can enjoy free shipping when your total purchase value is greater than or equal to $300 (a few items excluded).
We promise if you find there are quality problems with the goods received, we can provide you with return and exchange services.
Our telephone customer service staff work online form 9 am to 5 pm working days (Monday to Friday,Beijing Time).
We promise that all the products you buy on your platform are genuine.