Voltage(V): 230
Freq(HZ): 50/60
Current(A): 0.12/0.12
Power(W): 25/27
Speed(RPM): 2800/3300
Profantec FAN P2175HBT
People who bought this item also viewed
Sanyo Denki Fan 9CRA0912P0G001
Delta Fan GFC0412DS-CC50
Nidec Fan W40S12BS1D5-57
Delta Fan ASB1412HJ-01
OMRON Power Supply S8EX-P10005L
TRIAD Transformer TCT50-03E07AB
Danfoss Sight Glass SGR 014-0005
INFINEON IGBT Module F4_25R12NS4
EATON Relay EMR4-F500-2
ELNA Capacitor 6.3V 1F
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
SUNX Sensor PS-930A
AirTAC Air Cylinder ACQ25X55S
Schneider Circuit Breaker EZD630M4400K
TRIAD Transformer FD7-24
Recent related posts
-
09/21/2023
Geothermal, Air Source, and Water Source Heat Pumps: Which is the Best?
Heating and cooling are essential for maintaining comfortable living conditions in any building. Traditional HVAC systems use fossil fuels to generate heat, which is not only environmentally damaging but also expensive.
-
06/14/2020
Is PVC or PE good for domestic fresh air system pipes
Is PVC or PE good for domestic fresh air system pipes Fresh air system is a category of light equipment and heavy design. Fresh air equipment is highly dependent on design and construction.
-
06/22/2020
What's the matter with air conditioning and cooling without heating
What's the matter with air conditioning and cooling without heating 1.First, it may be because the vents of the indoor unit and outdoor unit are blocked by something, or a lot of dust has accumulated on the filter inside the air conditioner; 2. It may be because the heat blown from the air conditioner is seriously lost; 3 2. It may be because the amount of refrigerant in the air conditioner is too small, which leads to a great reduction in the heat exchange efficiency, so that the air conditioner does not heat. <img src="{{media url="magefan_blog/What_s_the_matter_with_air_conditioning_and_cooling_without_heating3.jpg"}}" alt="" />
-
03/08/2021
AC servo driver wiring precautions
For signal line and encoder input line, please use shielded wire. Wiring length: the length of signal line from NC to AC servo driver is less than 3m, and the length of input line from AC driver to encoder is less than 20m. The ground wire should be thick wire as far as possible. According to the third grounding standard (grounding resistance < 100 Ω), one point grounding method should be adopted to connect the ground wire. If the motor and the machine tool are insulated, the motor should be grounded.
-
06/14/2020
Compressor refrigeration oil testing and replacement
Compressor refrigeration oil testing and replacement For system manufacturers, the detection and replacement cycle of compressor refrigeration oil is related to the process control of the production process. If the cleanliness control of the evaporator a 器2 䀀 ᅵ皥 䖒皦즠Ʋ奌ི 㲈Ʋ 䌁皦 ᮔDž༬皧奖ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥
-
07/12/2020
To meet the needs of the refrigeration market, Danfoss 15HP refrigeration scroll compressor debut
The latest 15HP compressor MLM/MLZ116 is perfectly used in the fields of refrigerated and fresh-keeping storage, edible fungus storage, commercial refrigerated and refrigerated display cabinets, commercial ice machines, etc., helping unit manufacturers and engineering companies to reduce application costs.
-
06/14/2020
What to do if the refrigeration compressor is damaged
What to do if the refrigeration compressor is damaged After the refrigeration compressor in the refrigeration system is damaged, the new compressor cannot be replaced directly because there may be some incentives for the refrigeration compressor to be da 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦 ᮔDž༬皧嫦ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령
-
07/19/2020
Basic knowledge of refrigeration compressor
After shutting down, stop for at least 3 minutes before starting again to eliminate the pressure difference between the compressor inlet and outlet. Because in the case of a large pressure difference, the starting torque of the motor will increase, causing the current to rise to a certain level, the protector will act and the compressor cannot continue to run.
-
10/15/2021
Piston Compressor Basics - Structure, Working Principle, Advantages and Disadvantages
As both manufacturers and end customers know, in a refrigeration or air conditioning system, the compressor is the equipment core by continuously sucking back and exporting refrigerant
-
03/15/2024
What Is a Servo Motor? Types of Servo Motors