Output: Level Master NPN
Supply voltage: DC
Body size :20mm
Mounting verion: Non-flush
Output signal: Antivalent (NO + NC)
Thread / Process connection: M22 x 1,5
Rechner Sensor KAS-700-23-A-M22Capacitive proximity sensor
People who bought this item also viewed
Contrinex Sensor LTK-1040-301-506
TAKEX Sensor GTR1SPN
TAKEX Sensor DL-S5RPN
Honeywell Sensor 940-A4V-2D-001
Danfoss Transmitter 060G5951
Kromschroder Flame Detector UVS10D4G1
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Panasonic Servo Motor MSME252GCG
SCENERY Vane Pump SQP21-15-3-86CD-18
YSC Solenoid Valve YVDW2180
AirTAC Air Cylinder SUF40X600S
Yaskawa Servo Motor SGM-02A314P
Recent related posts
-
06/20/2020
[Experience] What happens if the compressor suction pressure is too high and the discharge pressure is too high
[Experience] What happens if the compressor suction pressure is too high and the discharge pressure is too high Compressor suction pressure is too high, discharge pressure is too high 1. Too much refrigerant. Too much refrigerant will cause the suction pressure and discharge pressure to be too high at the same time. This is because when too much refrigerant fills the reservoir, it will occupy a part of the condenser volume, reducing the heat dissipation area and causing the condenser Poor condensation. Discharge excess refrigerant from the low-pressure side.
-
06/22/2020
What is the reason why the freezer is not cooling
It may be that the capillary is blocked and the refrigerant flow does not enter the evaporator. It may also be that the refrigerant needs to be replenished or the refrigeration system is leaking. If the buffer tube inside the compressor ruptures, there may be loose screws or it will cause no cooling. It is also possible that the expansion valve and the discharge valve are not adjusted properly, causing cold air to leak out. Need to check one by one, and then take the medicine.
-
08/18/2020
Reasons for the high low pressure value of the chiller
In the application of industrial refrigeration, the chiller is used in conjunction with production and processing equipment, so it runs for a long time. If the customer lacks professional maintenance and routine equipment maintenance for the chiller in daily life
-
02/01/2024
Air Curtain 101: Working Principle, Types, Function, Application and Selection
Air curtain, also called air door curtain, air door, is mainly installed at the entrances and exits of public places with air-conditioning environments.
-
12/06/2022
How to Maintain a Linear Guideway?
Linear guideways are precision transmissions and require careful maintenance in order to give full play to their functions and prolong their service life. The followings are tips for the maintenance of the liner guideway
-
06/23/2020
Advantages and disadvantages of Hitachi central air conditioning
At present, the central air-conditioning of the refrigerant system is still the best done by Japanese brands. When it comes to Japanese central air-conditioning, one has to say that Hitachi, one of the Japanese air-conditioning BOSS, is a well-known international central air-conditioning brand. Most air conditioners now use scroll compressors as the core of power, and the world’s first scroll machine for air conditioning was manufactured by Hitachi in 1983.
-
07/27/2020
Selection and comparison of compressors
1. Piston compressor (the work of the piston compressor is the continuous change of the working volume formed by the cylinder, the valve and the reciprocating piston in the cylinder).
-
07/18/2022
What is Diaphragm Pumps
A diaphragm pump (also known as a Membrane pump) is a positive displacement pump that uses a combination of the reciprocating action of a rubber
-
09/05/2020
Top 10 tortures of frequency converters
There are ten major "tortures" of inverters today, which can also make your inverter suffer. Let's follow the editor of okmarts.com to explore the top ten "tortures" that will make your inverter "death than life"!
-
09/06/2021
Why is Your Car AC Starting and Stopping Frequently?
Many car owners are puzzled to find their air conditioners starting frequently while driving. In fact, the normal start and stop period of the air conditioner