RIKEN Contactor RAB-125N
Auxiliary Contact Structure N/C 2 N/O 2
Rated Operational Voltage (IEC) Ui 660V
AC1 Current (IEC) Ith 180A
AC3 Current (IEC) le 125A
AC3 Rated Capacity (IEC 60947-4-1) Three Phase
220V 30 KW 40 HP
380V 55 KW 75 HP
440V 55 KW 75 HP
550V 55 KW 75 HP
RIKEN Contactor RAB-125N
People who bought this item also viewed
SPRECHER+SCHUH Contactor CA4-9-10
RIKEN Contactor RAB-A0910
RIKEN Contactor RAB-450T
RIKEN Contactor RAB-A25
RIKEN Contactor BTH-2E26
Fuji Contactor SC-E3P-C
Fuji Contactor SK09G-E10
Fuji Contactor SC-E03A-G
Togami Contactor PAK-270H
CHINT Transformer TDGC3E-2
ABB Circuit Breaker 10113757
Ferraz Shawmut Fuse BS36UL69V315T
ROHM Resistor PSR500HTQFD0L30
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
THK Linear Guideway HSR25A2SS+640L
Delta Fan FFC0612DE-5C2K
SMC Solenoid Valve VP7-6-FHG-D-3N-X26
Nidec Fan U80T24MHA7-52
HAWE Overflow Valve CSVZ 2 E
SPRAGUE Capacitor 10V 1500UF
YI-SHING Vane Pump VP-40-FA3
Recent related posts
-
06/22/2020
Why is the air conditioner not cooling
Why is the air conditioner not cooling There are many factors for not cooling, for example: the selected air conditioner does not match the area of the room; improper installation of the air conditioner will cause the air circulation of the air conditioner to be unsmooth; when the indoor temperature is relatively high, the air conditioner cannot be cooled when turned on; It has been aging, or the service life has expired; the air conditioner has not been cleaned for a long time, and the filter surface is covered with dust; and the freon of the air conditioner has been seriously lacking. <img src="{{media url="magefan_blog/Why_is_the_air_conditioner_not_cooling.jpg"}}" alt="" />
-
09/23/2020
Application of DCS system in anti-surge control system of air separation compressor
Keywords: DCS system, air separation compressor, anti-surge control system Preface The 6000m3/h air separation plant of Xilin Iron and Steel Company was completed in May 2001 by Hangzhou Oxygen Concentrator Group Company. The factory design was designed by Beijing Iron and Steel Design Institute. It was successfully put into operation on September 2, 2001, and it took more than half a year to run. It shows that the unit is operating stably, and all indicators have reached or exceeded the design value. The entire control system uses Honeywell’s TDC3000 and two GUS stations.
-
07/21/2022
How to Prime a Water Pump
Water pumps will run out of pressure and stop working if turned off for an extended period of time, such as over the winter.
-
08/13/2020
New Explanation of Basic Knowledge of Small Chiller System
Small chiller: is a kind of water cooling equipment, small chiller is a kind of cooling water equipment that can provide constant temperature, constant flow and constant pressure.
-
08/02/2020
When air conditioners lack fluoride, five common leak detection methods will teach you who don’t understand!
When the air conditioner is lack of fluoride, the detection of leaks is the primary task of leakage repair. Today we introduce five common leak detection methods for you, namely fluorescent leak detection, soapy water leak detection
-
08/20/2020
How to adjust the energy of the compressor of the screw chiller
The compressors used in screw chillers generally have brands such as Taiwan Hanbell and German Bitzer, which belong to the screw compressor series. An obvious feature of this type of compressor is that it can perform an energy adjustment action on it according to different
-
04/28/2023
What Does the Compressor Do in the Refrigeration System
We know that whether it is an air conditioner or a refrigerator, a powerful compressor is needed to ensure its normal and efficient operation.
-
08/09/2023
Heat Pump Not Working in Cold Weather: Causes and Solutions
A heat pump is a popular heating and cooling system that works by transferring heat from one place to another. It can heat your home in the winter and cool it in the summer, making it a versatile and cost-effective option for many homeowners.
-
09/04/2020
The difference between ordinary asynchronous motor and variable frequency motor
1. Ordinary asynchronous motors are designed according to constant frequency and constant voltage, which cannot fully meet the requirements of variable frequency speed regulation
-
06/16/2020
Shinmatsu A certain customer regulation system Developmental electric compression line equipment line item officially introduced and used
Shinmatsu A certain customer regulation system Developmental electric compression line equipment line item officially introduced and used Flame flame summer day, the most painful period of time, incredible time, celebrating the baptism, small time trai 器2 䀀 ᅵ皥 䖒皦즠Ʋ㉄ᰙ 㲈Ʋ 䌁皦 ᮔDž༬皧㉎ᰙЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ