RIKEN Contactor RCR-A10-22
RIKEN Contactor RCR-A10-22
People who bought this item also viewed
RIKEN Contactor RAB-50N
RIKEN Contactor RAB-65N
RIKEN Contactor RAB-A09
RIKEN Contactor RAB-450T
Togami Contactor CLK-15J31-P6
HITACHI Contactor K50N-EP
HITACHI Contactor K50N-EPH
Nader Contactor NDC1Z-0910
TRIAD Transformer TCT50-01E07AE
DEHN Surge Protection Device DGP C S
LINDNER Fuse NH1-50A
OMRON Relay G6S-2-DC4.5
UniOhm Resistor 1W10R
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
SMC Proportional Valve ITV2030-013CS
Panasonic Light Curtain SF4B-F63-01<V2>
Contrinex Sensor BD22-S4-M30
Recent related posts
-
02/09/2024
Hot Air Circulation Tunnel Dryers: Structure, Working Principle, Features and Application
Tunnel dryer is a common drying equipment. It is widely used in food, medicine, chemical and other industries.
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
02/27/2021
Debugging method of servo motor
Before wiring, initialize the parameters. On the control card: select the control method; clear the PID parameters; let the default enable signal turn off when the control card is powered on; save this state to ensure that the control card is in this state when it is powered on again.
-
06/14/2020
Scroll compressor 2020 or will enter the dark moment
Scroll compressor 2020 or will enter the dark moment Affected by factors such as product competition and the weakening of downstream demand, in the context of the overall downturn in the HVAC industry,
-
08/04/2020
Analysis of five major problems in current heating management
With the development of society and the continuous improvement of people's living standards, traditional heating methods and management models have become less and less suitable for the development of the times.
-
09/11/2020
High exhaust temperature is the most common failure of screw air compressors
High exhaust temperature is the most common failure of screw air compressors, and its harm is also greater. Long-term operation of equipment under high exhaust temperature conditions mainly has the following hazards:
-
09/10/2020
Summary of features and failures of scroll compressors Deep analysis
The scroll compressor is a positive displacement compressor, and multiple compression chambers are formed by the meshing of the scroll rotor and the scroll stator. With the translation and rotation of the vortex rotator, the volume of each compression chamber continuously changes to achieve gas inhalation and compression.
-
09/14/2022
FAQs on Hydraulic Motor
According to the rated speed, hydraulic motors are divided into: high-speed hydraulic motors (rated speed higher than 500r/min), including gear, vane and axial piston types
-
06/29/2020
Analysis of the cause of excessive suction temperature of compressor
Analysis of the cause of excessive suction temperature of compressor The high suction temperature is mainly due to the increase of superheat of suction. Note that high suction temperature does not mean high suction pressure, because the suction is superheated steam. Under normal circumstances, the compressor cylinder head should be half cold and half hot. If the suction temperature is too high, the cylinder head will all heat up.
-
06/14/2020
Disassembly and failure analysis of scroll compressor
The scroll compressor is a positive displacement compression compressor, and the compression component is composed of a movable scroll and a static scroll. This includes many structural features that divert the flow of gas through the compressor housing t 器2 䀀 ᅵ皥