Input: 380-460V 3PH 2.0A 50/60Hz 1600VA
Output: 380-460V 3PH 1.7A 0-240Hz
Operating ambient temp: 0-50 degree Celsius
Rockwell AB VFD Frequency Converter 160-BA02PSF1
People who bought this item also viewed
Fuji VFD Frequency Converter FRN5.5G11S-2
ABB Servo Motor PS 90/6-57-P-LSS-4003
Rockwell A-B HMI 2711P-K7C4A8
Johnson Controls Actuator M9108-ADC-1N
GGM Speed Reducer K6H50BTH
MITSUBISHI Spindle Amplifier MDS-B-V1-20
Allen Bradley Input Output Module 5069-OW16
GS Battery 36B20RS
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
LS Mecapion Encoder S48-8-0060BT
SUNON Fan MG60090V1-C040-S99
Shinko Temperature Controller PCB1S00-45
Recent related posts
-
07/16/2020
How to clean the constant temperature and humidity box condenser
The condenser of the constant temperature and humidity test chamber should be maintained regularly on a monthly basis. Use a vacuum cleaner to absorb the dust adhering to the condensing heat dissipation mesh or use high-pressure air to remove the dust.
-
06/13/2020
Refrigeration unit in artificial environment simulation laboratory
The artificial environment simulation laboratory can simulate the temperature and humidity environment, as well as the climatic environment of rainfall, snowfall, sunshine, wind, sand and dust.
-
08/16/2020
What to pay attention to when the refrigeration equipment is moved
Because the company needs to change the working environment, all the equipment of the company must be moved, and the refrigeration equipment in the disassembly and installation process requires staff with rich professional knowledge,
-
01/21/2022
AC Compressor Bearing - Working Principle & Troubleshooting
Bearings play an irreplaceable role in mechanical design. They involve very wide applications.
-
06/25/2020
Comparison of characteristics of Hitachi inverter scroll compressors for household and commercial and vehicle air conditioning
Comparison of characteristics of Hitachi inverter scroll compressors for household and commercial and vehicle air conditioning Due to the different applications, Hitachi inverter scroll compressors have different characteristics.
-
09/22/2020
Compressed air dewatering, oil removal and dust removal multifunctional filter
Compressed air degreasing, water removal and dust removal filter (purification equipment) Sometimes, connecting a piece of equipment to a compressed air supply station cannot solve the quality of compressed air.
-
09/09/2020
Method of controlling noise of air compressor
Control of noise pollution of air compressors Noise is a kind of sound that people don’t need. It is a kind of public hazard that has been raised to the agenda and needs to be solved. Noise pollution is multifaceted, but the pollution of air compressor noise is classified.
-
07/29/2020
Adding fluoride to the air conditioner is tricky, don't be fooled!
remind<br></br> In the hot weather, many citizens have begun to use air conditioners to remind everyone to be careful not to be fooled by unnecessary "air conditioner filling
-
08/17/2020
The difference between a single-head chiller and a double-head chiller
1. Single-stage refrigeration system 1. The single-stage refrigeration cycle refers to the four processes of compression, condensation, throttling,
-
08/19/2020
The impact of excessive or small pump flow on the chiller
The chiller may have various types of failures. Why does the water pump fail with too much or too little flow?<br></br> In fact, whether the flow of the water pump is too large or too small, it will have a certain impact on the operation of the chiller, so it is not a good thing that the flow is too large or too small.