Input: 380-460V 3PH 2.8A 50/60Hz 2200VA
Output: 380-460V 3PH 2.3A 0-240Hz
Operating ambient temp: 0-50 degree Celsius
Rockwell AB VFD Frequency Converter 160-BA03PPS1P1
People who bought this item also viewed
Lenze VFD Frequency Converter EDK82EV113
Inovance VFD Frequency Converter MD500T75G
Inovance VFD Frequency Converter MD500T55G
Schneider Servo Motor BCH0802O32A1C
Yaskawa Servo Drive SGDH-75AE100
Delta HMI HMC07-N411H5CA
Johnson Controls Actuator M9203-BUA-1
Mean Well Power Supply LRS-350-4.2
GGM Speed Reducer K9P120BUF
B&R CPU Module X20CP1484-1
TADIRAN Battery TL-2150-P
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
KOYO Absolute Rotary Encoder TRD-MA512RN
SHAKO Air Cylinder ICB40C450
Recent related posts
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
12/05/2022
Materials for Linear Guideways
Linear guideways are widely used in transmission system and have many characteristics such as high hardness, high accuracy, etc. These are largely attributed to the advanced material they use.
-
06/21/2020
Working principle of sliding vane compressor_Features of sliding vane compressor
Working principle of sliding vane compressor <img src="{{media url="magefan_blog/Working_principle_of_scroll_compressor_Characteristics_of_scroll_compressor.jpg"}}" alt="" /> Air is sucked in through a filter and a regulating proportional valve. The regulating valve is mainly used to regulate the pressure chamber formed by the rotor and slide of the air cylinder. The rotor rotates eccentrically with respect to the cylinder, the valve plate is installed in the rotor groove, and the slider is pushed to the cylinder wall by centrifugal force.
-
07/19/2022
What is Diaphragm Pumps
A diaphragm pump (also known as a Membrane pump) is a positive displacement pump that uses a combination of the reciprocating action of a rubber
-
03/11/2021
The main circuit fuse fusing is a common fault of SCR servo driver. The causes of fuse fusing are as follows
The "phase sequence" of power incoming line is incorrect. Due to the synchronization problem between the trigger pulse and the main circuit of SCR servo driver, there are strict requirements on the "phase sequence" of the input power supply. If the "phase sequence" is not correct, connecting the power supply may immediately cause the fuse of the main circuit of the driver to blow.
-
06/25/2020
What are the three tubes of the refrigerator compressor
What are the three tubes of the refrigerator compressor 1. The general refrigerator compressor has three pipe ports;
-
07/03/2020
Portable Oil Free Air Compressor Market Size 2020-2026 Review, Key Findings, Growth Strategy, Developing Technologies, Trends And Global Forecast By Regions
The Stationary Oil Free Air Compressor Market report includes overview, which interprets value chain structure, industrial environment, regional analysis, applications, market size, and forecast. This is a latest report, covering the current COVID-19 impact on the market. The pandemic of Coronavirus (COVID-19) has affected every aspect of life globally.
-
05/13/2022
6 Considerations When Selecting PLC?
The operating functions of PLC include logic operation, timing and counting functions. The simple operating functions include data shift, comparison, etc
-
07/20/2020
Analysis of circuit diagrams of two compressors' phase failure protection
Analysis of circuit diagrams of two compressors' phase failure protection Air compressor phase failure protection circuit Protection circuit diagram Air compressor phase failure protection circuit
-
07/02/2020
Danfoss US Youle MANEUROP compressor MTZ-28 latest offer wholesale parameters performance introduction
Danfoss US Youle MANEUROP compressor MTZ-28 latest offer wholesale parameters performance introduction Danfoss US Youle MANEUROP compressor MTZ-28 offer wholesale parameters, distributor Technical parameters of Meiyou compressor: