ROFES Butterfly Valve 5046100B16
People who bought this item also viewed
EVAC Mechanical Seal 109-15
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Cutler Hammer Circuit Breaker JW40K JW3250F
NEW-ERA Air Cylinder SR-12-90
Recent related posts
-
08/11/2021
How to Tell if Your Refrigerator Compressor is Bad
The refrigerator malfunction may be caused by the refrigeration system or the electrical system. When judging the compressor fault
-
09/04/2020
Eight core issues warn compressor companies, and the rapid changes in the market cannot be ignored
When we find that the hot companies a few years ago have become traditional enterprises, you will understand how fast we are in an era of change! Most compressor companies now have a very serious sense of crisis-dealers are difficult to manage
-
08/08/2023
How to Defrost a Heat Pump: A Comprehensive Guide
Heat pumps are an essential component of HVAC systems that provide both heating and cooling solutions for homes and commercial buildings. However, like any other mechanical device, they require maintenance and care to operate efficiently and effectively.
-
09/09/2020
Is the scroll air compressor good
Scroll air compressors are still good, especially for users who use piston machines. Scroll air compressors are cheaper than screw air compressors. They are quite light in sound and are more suitable for enterprises or factories with small air consumption.
-
06/13/2020
Cold storage construction guide
Cold storage construction guide Cold storage construction guide 1. Select the appropriate volume and temperature range of the cold storage according to its own use and requirements;
-
06/13/2020
York NGC200 Petroleum Coal Chemical Screw Refrigeration Compressor Oil Temperature Excessive Failure Overhaul
York NGC200 Petroleum Coal Chemical Screw Refrigeration Compressor Oil Temperature Excessive Failure Overhaul York NGC200 Petroleum Coal Chemical Screw Refrigeration Compressor Oil Temperature Excessive Failure Overhaul, Oil Temperature Excessive Failure ﰸ2 䀀 ᅵ皥
-
06/20/2020
Common failure and analysis of centrifugal air compressor
Common failure and analysis of centrifugal air compressor 1. Abnormal vibration and noise: ① Misalignment ② The compressor rotor is unbalanced ③ The impeller is damaged ④ The bearing is abnormal ⑤ The coupling is faulty or unbalanced ⑥ The sealing ring is bad ⑦ The oil pressure and oil temperature are abnormal ⑧ There is dirt in the oil Clean, wear out the bearing ⑨ Surge ⑩ The stress of the gas pipeline is transmitted to the casing, which causes misalignment ⑪ There is a machine working near the compressor<img src="{{media url="Common_failure_and_analysis_of_centrifugal_air_compressor.jpg"}}" alt="" />
-
06/13/2020
How to choose refrigeration oil for refrigeration compressor and unit
How to choose refrigeration oil for refrigeration compressor and unit The lubricating oil of the refrigerator is different from other mechanical equipment. Due to the different use occasions and refrigerants, the choice of lubricating oil for the refrige 器2 䀀 ᅵ皥 䖒皦즠Ʋ煔क़ 㲈Ʋ 䌁皦 ᮔDž༬皧煞क़Ѐ 呄ᠾ鹨់༹皧 ࠄ
-
06/19/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
07/01/2020
Precautions for the use of screw air compressor oil
Precautions for the use of screw air compressor oil Precautions for the use of screw air compressor oil: It is forbidden to mix air compressor oils of different brands and grades. The old oil must be drained when replacing. It is strictly forbidden to add or filter and reuse. Because although the color of the compressor oil does not change on the surface, the consumption of additives may have exceeded the limit.