There is no price at present, you can Request a Quote
Minimum detection object: diameter 14 mm
Optical axis distance / lens diameter: 10 mm / diameter 4
Detection distance: 0.2 to 10 m * 1
Effective opening angle: +/- 2.5 degree (above 3 m)
light source: Infrared LED (870 nm)
Response time (OSSD) (ms):
Wired sync or Light sync (channel 0):
ON OFF: 17.3
OFF ON: 64.7 * 2
Asynchronous ON: 105.9 * 3
Light sync (channel A or B): ON OFF: 26
During light synchronization (channel A or B):
OFF ON: 77.8 * 2
Asynchronous ON: 140.8 * 3
Detection method: Turn on when the beam axis is receiving light (except when using the fixed blanking function)
Synchronously: Optical synchronization / Wired synchronization (can be selected according to wiring)
Prevent mutual interference function: Light synchronization: interference prevention for up to 2 devices with the setting of a button
Wired sync: Automatic interference prevention for up to 2 devices
Control output (OSSD output):
Output type: Transistor output × 2 (PNP / NPN can be switched according to the cable)
Load current: 500 mA or less * 4
Residual voltage (when open): 2.5V (at 5 m cable)
Voltage when closed: 2.0V (at 5 m cable)
Leakage current: 200 ?A max
Maximum load capacity: 2.2 ?F
Load connection resistance: 2.5 ohm max
Auxiliary output(Non-safety output):
AUX:
Error output: Transistor output (PNP / NPN can be switched according to the cable)50mA or less, residual voltage 2.5V or less (at 5 m cable)
Backlight does not protect lamp output: Incandescent (24 VDC, 1 to 5.5 W)LED light (load current 10 to 230 mA)
External input:
When using a PNP output cable:
Turn-on voltage: 10 to 30V
Off voltage: open or 0 to 3V
Short-circuit current: about 2.5 mA (only 10 mA for EDM input)
When using NPN output cable:
Turn-on voltage: 0 to 3V
Off voltage: open circuit or above 10V
Below power supply voltage
Short-circuit current: about 2.5 mA (only 10 mA for EDM input)
Rating: voltage: 24VDC +/- 20% ripple (P-P) less than 10% class2
power supply:Consumption current(At maximum) (mA):
launcher76 * 5
receiver87 * 5
protect the circuit: Reverse power protection, short-circuit protection for each output, surge protection for each output
Meet specifications:
EMC:
EMS: IEC61496-1, EN61496-1, UL61496-1
EMI: EN55011 ClassA, FCC Part15B ClassA, ICES-003 ClassA
Safety:
IEC61496-1, EN61496-1, UL61496-1 (Type4 ESPE)
IEC61496-2, EN61496-2, UL61496-2 (Type4 AOPD)
IEC61508, EN61508 (SIL3), IEC62061, EN62061 (SIL CL3)
EN ISO13849-1: 2015 (Category 4, PLe)
UL508
UL1998
Environmental resistance:
Enclosure protection level: IP65 / IP67 (IEC60529)
Overvoltage category: II
Ambient light: Incandescent lamp: 3,000 lux or less, Sunlight: 20,000 lux or less
Use ambient temperature: -10 to +55 degree C (no freezing)
Ambient storage temperature: -25 to +60 degree C (no freezing)
Use of ambient humidity: 15 to 85% RH (non-condensing)
Storage environment humidity: 15 to 95% RH
Earthquake resistance: 10 to 55 Hz, double amplitude 0.7 mm, 20 sweeps each in X, Y, and Z directions
Impact resistance: 100 m / s2 (about 10 G), 16 ms pulse, 1,000 times each in X, Y, and Z directions
Material:
Body shell: aluminum Upper cover / lower cover: Nylon (GF30%)
Front shell: Polycarbonate, SUS304
weight:
launcher: 1700 g
receiver: 1700 g
* 1 When the optional front protective case is mounted on one side of the transmitter and receiver, the detection distance will be shortened by 0.5 m. When installed on both sides, it is shortened by 1 m.
* 2 When the light-shielding time is 80 ms or less, in order to make the OSSD close for 80 ms or more, the response time
(OFF ON) will be later, at least 80 ms.
* 3 "Asynchronous ON" refers to the state where the transmitter and receiver are not synchronized when the optical synchronization is used (upper and lower ends)
The optical axis is in a light-shielded state) to the time required to turn on. After the transmitter and receiver are synchronized,Light and light, response time becomes longer.
* 4 350 mA at an ambient temperature of 50 to 55 degree C.
* 5 If each input other than the EDM input is on, the current consumption of each input will increase by 2.5 mA.
KEYENCE Light Curtain GL-R119F
There is no price at present, you can Request a Quote
People who bought this item also viewed
YINGB Light Curtain GMNB-08-2-C
SICK Light Curtain C4MT-07214ABB04FE0
IFM Sensor O6H701
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Ziehl Abegg Fan FN050-4EK.4I.V7P1
Dwyer Flowmeter VFCII-141
Banner Sensor SMW915F
Recent related posts
-
08/11/2020
How to use semi-hermetic refrigeration compressor to save energy
The increasing population has made the problem of scarcity of resources increasingly serious, especially some non-renewable resources, which have become the focus of the struggle between countries.
-
06/29/2020
Too small selection results in insufficient compressor displacement
Too small selection results in insufficient compressor displacement Many users just start not knowing the specific gas consumption of their own production, so they blindly select the model according to their own estimates, resulting in exhaust pressure not coming up, below the rated exhaust pressure, which cannot meet the normal gas consumption of the factory.
-
02/03/2023
6 Types of Commonly Used Gear Reducers
Gear reducers are generally used for transmission equipment with low speed and high torque. The ratio of the numbers of teeth of the big and small gears equals the transmission ratio.
-
09/14/2020
Analysis of the consequences of refrigerant liquid entering the compressor
When the refrigerant liquid entering the evaporator is too much or the evaporation pressure is too low, the cold The medium liquid will be sucked into the compressor. Since the refrigerant liquid is incompressible,
-
06/13/2020
Scroll compressor
Scroll compressor
-
07/30/2020
How to detect inferior refrigerants What's the harm
Inferior refrigerants will affect the performance and stability of the system, and even more serious will cause damage to system components and compressors. The following methods can be used to distinguish whether it is a low-quality refrigerant:<br></br
-
06/13/2020
Liquid Refrigerant, Dense Vapors Can Damage Compressors
To prevent these conditions
-
06/13/2020
Compressor related industry information: in June, more than 30 countries in the world further expanded the scope of unsealing.
Compressor related industry information: in June, more than 30 countries in the world further expanded the scope of unsealing. After the most difficult period of global multi-national blockade, with the passage of time, many countries have begun to "unse 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦 ᮔDž༬皧嫦ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱
-
06/13/2020
The reason for the failure of the multi-line air-conditioning compressor is revealed!
The reason for the failure of the multi-line air-conditioning compressor is revealed! 1 Overview The failure of motor compressor (hereinafter referred to as compressor) can be divided into motor failure and mechanical failure (including crankshaft, co 器2 䀀 ᅵ皥 䖒皦즠Ʋ煔क़ 㲈Ʋ 䌁皦 ᮔDž༬皧煞क़Ѐ
-
07/03/2020
GLOBAL REFRIGERANT COMPRESSOR MARKET COMPANY PROFILE, REGIONAL ANALYSIS, INDUSTRY GROWTH 2020-2025
According to a new report published by Eon Market Research, titled, ”Global Refrigerant Compressor Market by Product Type and End-Users/Application Global Market Share, Forecast Data, In-Depth Analysis, and Detailed Overview, and Forecast, 2020 – 2025″ – By Regions (USA, Europe, Japan, China, India, South East Asia).