There is no price at present, you can Request a Quote
Rated output:3000(W)
Phase:Three(Φ)
Rated voltage:380(V)
Frequency:60(Hz)
Diameter:50A×40A
Total head:32(m)
Rated flow rate:470(L/min)
Sanso Magnet Pump PMD-37013
There is no price at present, you can Request a Quote
People who bought this item also viewed
PAN WORLD Magnet Pump NH-405PW-F-AV
Becker Vacuum Pump U4.195
DEBEM Diaphragm Pump IB50-FC-MTTFT
WALRUS Water Pump TPH12T5K
KSB Mechanical Seal KSB-32
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
PALL Filter HC9010FKP8H
Schneider Servo Drive LXM23CU07M3X
BHC Capacitor ALP22A471DD385
PARKER Oil Seal BS63*75*9
DAITO Fuse LM03
HONGFA Relay HFKW-012-SHW(164)
Recent related posts
-
08/16/2020
What is the difference between a water source heat pump and a water ring heat pump
1. Water source heat pump technology Water source heat pump technology is a low-temperature low-level thermal energy resource formed by using solar energy and geothermal energy absorbed from shallow water sources on the earth's surface
-
06/13/2020
Is there any problem with compressor oil return
Is there any problem with compressor oil return 1. Mechanism analysis of compressor oil shortage During the operation of the system, the lubricating oil is discharged from the compressor along with the refrigerant, and then returned to the compressor 器2 䀀 ᅵ皥 䖒皦즠Ʋ焬क़ 㲈Ʋ 䌁皦 ᮔDž༬皧然क़Ѐ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ
-
11/03/2021
How to Install Hollow Shaft Encoders, Problems & Solutions
Hollow shaft encoder is also known as hollow encoder. When installing this type of encoders, it is necessary to avoid rigid connection with the encoder.
-
11/15/2021
Compatibility Error Between Fuji HMI and Siemens PLC and the Solutions
With the development of computer network and fieldbus technology, PLC and HMI are widely used in industrial control and building automation.
-
09/10/2020
Summary of features and failures of scroll compressors Deep analysis
The scroll compressor is a positive displacement compressor, and multiple compression chambers are formed by the meshing of the scroll rotor and the scroll stator. With the translation and rotation of the vortex rotator, the volume of each compression chamber continuously changes to achieve gas inhalation and compression.
-
10/18/2021
When You Should Use an Absolute Encoder - Pros and Cons of Different Absolute Encoders
As is known to us, rotary encoders consist of incremental encoders and absolute encoders. And absolute encoders are much more expensive than incremental encoders.
-
06/22/2020
How to add air conditioning refrigerant
Turn off the power supply of the air conditioner first; if all the light leaks, then you must evacuate before adding it; find the thick tube under the outdoor unit and add fluorine from here; you need to install the pressure gauge when adding fluorine Generally, it can be stopped at about 5 pressures; the temperature needs to be turned to the lowest when turning on the machine, and observe for about half an hour.
-
06/13/2020
The main cause of the burning of refrigeration compressor windings
The damage of the motor coil is mainly manifested as the destruction (short circuit) and open circuit of the stator winding insulation. After the stator winding is damaged, it is difficult to be found in time, which may eventually cause the winding to bur 器2 䀀 ᅵ皥 䖒皦즠Ʋ煔क़ 㲈Ʋ 䌁皦 ᮔDž༬皧煞क़Ѐ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱
-
09/04/2020
Analysis of the advantages and disadvantages of 5 types of compressors
There are mainly 5 types of compressors, piston compressors, rolling rotor compressors, turbo compressors, screw compressors, and centrifugal compressors. This article briefly introduces the advantages and disadvantages of various compressors.
-
08/19/2020
Installation of air conditioning and refrigeration system equipment
1. Installation preparation (1) Check and accept the equipment foundation according to the construction drawings. Measure the position and elevation of the pipeline shown, and find out the embedded parts of the support and hanger.