There is no price at present, you can Request a Quote
3kw
We can also provide the following models
C-SDP225L33J
C-SCX320L16F
C-SC601H5Q
C-SBX215H01I
C-SDP135L33D
C-SB303H1Z
C-SCP315L33E
C-SBR180H36K
C-SBP230L02T
C-SBX120L03C
C-SCN113H1A
C-SCN523H0J
C-SBX145L16A
C-SBX165L02N
C-SCP360L15Z
C-SBR110L03Q
C-SBX120L33L
C-SCX295L35E
C-SBN231H6C
C-SC453L1E
C-SDP190H03M
C-SC901L1L
C-SBR180L33F
C-SDP170L01Y
C-SCX320H38Q
C-SCN523H5T
C-SCVN603H1O
C-SBR110H35C
C-SCV603H5B
C-SBX180L00D
C-SBP140L03U
C-SBX165H02S
C-SCP315H16X
C-SCX320H02T
C-SCX320H35N
C-SBS165H33Q
C-SBX150H39N
C-SBR120H33M
C-SCS370H38L
C-SBR1220L01U
C-SCN113H5O
C-SBS235H02Z
C-SC581L9Y
C-SC581H1Z
C-SBN371H9C
C-SCV603H3P
C-SBS215L15E
C-SDP135H36Z
C-SBR261H33G
C-SBX145L33Y
For more information,please contact us freely
Sanyo Compressor C-3RV438H2
There is no price at present, you can Request a Quote
People who bought this item also viewed
Tecumseh Compressor RK5512Y-NA3A
Mitsubishi Compressor YB645GUD
Mitsubishi Compressor RB247YFY
Sanyo Compressor C-SBR145H15P
Sanyo Compressor C-9RVN393H0V
Sanyo Compressor C-RH223L8C
Sanyo Compressor C-SB453H8G
Daikin Compressor JT90BH-Y1L
Tecumseh Compressor AEZ2415Z
Danfoss Compressor HCM120T4LC6
GMCC Compressor PH225X2C-8FTC1
TRIAD Transformer F-117X
Parker Sporlan Expansion Valve SEHI-400-20-S
Fuji Contactor FC-1S
Nidec Fan D06E-24PG
ABB Electric Motor QABP71MA4
Danfoss Sight Glass SGN19S
MUNDORF Capacitor 1400V 0.33UF
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
SMC Solenoid Valve VFS5410-5DZB-04
AirTAC Air Cylinder ACQ25X120
THK Linear Guideway SHW17CR1UUM
Recent related posts
-
08/08/2020
How much electricity does a 1.5-hp air conditioner need to work for 10 hours a night
How much electricity does a 1.5-hp air conditioner need to work for 10 hours a night When the indoor temperature reaches the preset temperature, as long as the outdoor compressor and electric fan stop running, the indoor cabinet electric fan will continueﰨ2 䀀
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
09/09/2020
What are the problems of traditional air compressors compared with frequency conversion air compressors
Variable-frequency air compressors have certain advantages in many aspects, so what are the problems of traditional air compressors compared to variable-frequency air compressors? Today I will tell you about the problems of traditional air compressors.
-
08/14/2020
Four Steps to Refrigeration Compressor Maintenance
Summer is coming, and the long-standing air conditioner will come in handy again! In recent years, consumers have become more and more experienced in the use of air conditioners,
-
09/15/2020
The difference between micro vacuum pump and gas sampling pump
Usually we call small-volume pumps that can generate negative pressure as micro-vacuum pumps, but we must strictly distinguish them when selecting products.
-
09/07/2021
How to Test a Mass Flow Sensor?
The mass flow sensor, or air flow sensor is one of the important sensors of the electronic fuel injection engine.
-
03/14/2024
Difference between AC, DC and EC Fans
AC fans, DC fans and EC fans are classified according to their power supply type and motor type respectively. They differ in drive method, performance and application range.
-
08/05/2022
FANUC Spindle Amplifier Alarm Codes and Solutions (3)
The following is a continuation of the previous article, and introduces FANUC spindle drive alarm codes 47-73.
-
09/21/2020
Refrigeration system failure symptoms
Symptoms of refrigeration system failure 1. Detection of pressure and temperature of refrigeration system (1) The pressure concept of the refrigeration system The refrigeration system can be divided into high and low pressure during operation. The high pressure section is from the discharge port of the compressor to before the throttle valve. This section is called the evaporation pressure.
-
07/10/2022
How to Replace Mechanical Seals in Centrifugal Pumps
Mechanical seals are used in centrifugal pumps to keep water or any liquid from making contact with the delicate parts of the machine.