Product name | DC Fan |
Frame material | Plastics |
Series | San Cooler 80 |
Frame size(mm) | Square - 80mm L x 80mm H |
Frame thickness | 25.00mm |
Rated voltage[V] | 24VDC |
Rated current[A] | 0.05 |
Rated input[W] | 1.2 W |
Rated speed[min-1] | 2350 |
Max. airflow[m3/min] | 0.820 m3/min |
Max. airflow[CFM] | 29.3 CFM |
Max. static pressure[Pa] | 22.4 Pa |
Max. static pressure[inchH2O] | 0.090 |
SPL[dB(A)] | 23.0 dB(A) |
Expected life[h] | - |
Sensor type | - |
IP rating | - |
PWM control function | - |
Bearing Type | Ball |
Fan Type | Tubeaxial |
Features | Locked Rotor Protection |
RPM | 2350 RPM |
Termination | 2 Wire Leads |
Operating Temperature | -4 ~ 158~F (-20 ~ 70~C) |
Approval Agency | CSA, TUV, UL |
Weight | 0.199 lb (90.26 g) |
Description FAN 80X25MM 24VDC
Description Fan tube shaft type 24VDC square-80mm long x 80mm high ball 29.3 CFM (0.820m?/min) 2 leads
Moisture Sensitivity Level (MSL) Not applicable
Series San Ace 80
Part status on sale
Voltage-24VDC nominal
Size/dimension square-80mm long x 80mm high
Width 25.00mm
Air flow 29.3 CFM (0.820m?/min)
Bearing type Ball
Fan type Tube shaft type
Features-
Noise 26.0 dB(A)
Power (W) 1.08W
RPM 2350 RPM
Terminate 2 leads
Intrusion protection-
Operating temperature -
Voltage range 6 ~ 13.8VDC
Material-Frame Plastic
Material-Blade Plastic
We can also provide the following models
9GV1505H7D011
9GA1424M9D011
9GV0405D702
9GP5748P1GD01
9WV0948H1002
9GV0448B6D0011
9GV1712A0002
9HV0512H301
9BJ24F0011
9GA1205W3D01
9GA0405A0D01
9GA1312M7023
9HV4712C60023
9GV1324K10011
9GV5748J6D001
9GV0848K2D001
9LG1448J5D001
9GA1424M302
9HV1324D9023
9GV1248H3D011
9WL0948E402
9GA0512J20011
9HV1348B2D013
9GV4724J50023
9GV1205K6021
9GV0912F0011
9WV1248S6D01
9GV4748L6011
9GA0512H602
9HV0912G4D0013
9GV1548E6021
9GV4705J20021
9WL0412A5H0021
9GV0348D7013
9HV2048H101
9GA5724H0D0011
9GA2012E301
9GA3612S7D011
109BMB24K16-1
9GA0924G6002
9GV0848H5D01
9GA5724M4001
9GA2012K40011
9HV1705B5D01
9GA1524H2013
9HV4712K30021
9HV1424B901
9GV1524D901
9HV0305A601
9HV1712E302
9WL5712A602
9WL0924D5001
9WV0924D6H002
9WV1724S1HD011
9L0824L8D001
9HV1724L60013
9GV0348W7D01
9HV0612D5013
9LG1212L802
9GA0448H3D0011
9GV2048C10013
9GA1748L20021
9GA0812G5D001
9GV1224L002
9GA3648H90011
9GV0405F0D001
9HV3624H9002
9HV0405C70011
9GA1324J4002
9GV3648F9D0013
9GA3624B0D0013
9GA0405B50021
9HV0805W502
9HV5705W5013
9GA3648L70021
9HV5705K5D01
9GV0912A10023
9GA0905C401
9GA1412W001
9WV5712D6D0011
9GA5712B0021
9GV1524L9D013
9GV1548D9D0013
9GV1512M9D0011
9HV1212S1D001
9HV1205A0D0011
9GA0524B10023
9GV3648D60023
9GV0524C0D0011
9GA5748H60021
9GA0348S70011
For more information,please contact us freely
Sanyo Denki Fan 9A0824M402
People who bought this item also viewed
ADDA Fan AD0412HB-J93
Pelko Motors Fan R1238Y24BPCB1-7
Sanyo Denki Fan 9GV3612P3G04
Sanyo Denki Fan 109E2024S002
Sanyo Denki Fan 109P0424H6D01
Sanyo Denki Fan 109P0412H744
SUNON Fan ME92251V3-000U-G99
ORION Fan OD1225-24LBIP68
ORION Fan OD8038-12HBIP69K
Ebmpapst Fan R2E190-A012-92
Sanyo Compressor C-SBP205H38Q
COSEL Power Supply LFA150F-24-SR2Y
TRIAD Transformer FP120-20
Shihlin Circuit Breaker BHL23 D4
TROMBETTA Contactor 684-1261-212-17
Danfoss Sight Glass SGP12SN
Beckhoff Module KS2532
SAWANA Relay JSS20-A1 AC220V
SPRAGUE Capacitor 630V 0.1UF
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
SHAKO Solenoid Valve PU225S-08
Recent related posts
-
11/19/2023
Difference in 2 Pin, 3 Pin and 4 Pin Computer Fans: Which is better?
If a computer does not have a radiator, its internal temperature will be infinitely high, and eventually the hardware will be burned directly. Whether it is for the CPU, graphics card, chassis, or power supply, heat dissipation is required.
-
08/20/2020
Trouble phenomenon the air conditioner is not cooling, the outdoor unit starts and stops frequently
When the air conditioner is frequently used in summer, many friends will encounter this problem, that is, the outdoor unit of the air conditioner frequently starts and stops, but the indoor unit is not cooled.
-
08/21/2020
Common problems and solutions for ice making machines
1. Common problems and solutions of ice maker 1. The compressor is working but not cooling. Reason: The refrigerant leaks or the two-way solenoid valve is damaged and it is not closed tightly.
-
06/30/2020
Causes of compressor burnout
Causes of compressor burnout Common failures of compressors are mainly the following three: 1. Motor burned out; 2. Liquid shock; 3. Oil shortage caused by refrigeration oil. Today I will give you a detailed analysis of the cause of the motor burnout.
-
06/14/2020
Don't panic if the refrigeration compressor suddenly stops, remember these methods!
What should be paid attention to when the refrigeration compressor stops abnormally? Some friends may not understand it. Let's take a look at it with everyone today!
-
09/22/2020
Compression and delivery of air compressor
The compressor can convert the mechanical energy of the motor or internal combustion engine into the pressure of compressed air. Air compressors are divided into two categories: reciprocating and rotary. The following figure shows the basic types of compressors:
-
07/23/2020
The influence of capillary tube length on refrigeration system parameters and troubleshooting
The capillary tube generally refers to a slender copper tube with an inner diameter of 0.4~2.0mm. As the throttling mechanism of the refrigeration system, the capillary tube is the simplest one. Because of its low price and flexible selection, it is widely used in small refrigeration devices.
-
08/11/2020
Matters needing attention in improving the quality of cold storage installation
In fact, different construction methods and installation materials are the key to directly affecting the smooth progress of the cold storage installation project.
-
06/16/2020
What is the reason for the noisy central air conditioning and how to solve it
What is the reason for the noisy central air conditioning and how to solve it Causes and solutions of large noise in central air conditioning First, the installation process is not in place It is said that the Daikin central air conditioner is "th 器2 䀀 ᅵ皥 䖒皦즠Ʋ奌ི 㲈Ʋ 䌁皦 ᮔDž༬皧奖ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿먲僧ᐱ㥲ᐲ�僬㣢ᐲ ᠾ 랖僧Ҍ 識 �僬㣢ᐲ 臆S㥲ᐲ ᬄğ 識 理艏S
-
08/16/2020
What parameters should be understood when choosing a central air-conditioning air-cooled heat pump unit
You must be familiar with central air-conditioning, but did you know that there is a unit in central air-conditioning called a cold and heat pump unit? The work of central air-conditioning is inseparable from it.