Product name | DC Fan |
Frame material | Plastics |
Series | San Ace 80 |
Frame size(mm) | Square - 80mm L x 80mm H |
Frame thickness | 38.00mm |
Rated voltage[V] | 12VDC |
Rated current[A] | - |
Rated input[W] | 18.24 W |
Rated speed[min-1] | - |
Max. airflow[m3/min] | 2.96m³/min |
Max. airflow[CFM] | 104.5 CFM |
Max. static pressure[Pa] | 306.4 Pa |
Max. static pressure[inchH2O] | 1.230 in H2O |
SPL[dB(A)] | 53.0dB(A) |
Expected life[h] | - |
Sensor type | - |
IP rating | - |
PWM control function | - |
Bearing Type | Ball |
Fan Type | Tubeaxial |
Features | Locked Rotor Protection, PWM Control, Speed Sensor (Tach) |
RPM | 8250 RPM |
Termination | 4 Wire Leads |
Operating Temperature | -4 ~ 158°F (-20 ~ 70°C) |
Approval Agency | cURus, TUV |
Weight | - |
Sanyo Denki Fan 9RA0812P1K0011
People who bought this item also viewed
Ebmpapst Fan K3G280-RR04-H9
Sanyo Denki Fan 109-153
Sanyo Denki Fan 9WF0624H7D04
Sanyo Denki Fan 9GA0412P3J01
Sanyo Denki Fan 9WL0612P4S001
Sanyo Denki Fan 109E1224M445
SUNON Fan KDE2404PKV2
Nidec Fan D06G-12TH
Sanyo Denki Fan 9G0824H102
Mean Well Power Supply ELG-240-42A
CHINT Transformer QZB-J-75
Siemens Contactor 3RT2517-2GG20
DKM Electric Motor 9BDGC-90FP
LEEMIN Filter NLX-630-30
EMERSON Sight Glass HMI-STT5
Beckhoff Module KL4418
SCHMERSAL Relay AES 1112
Sanyo Capacitor 10V 330UF SS
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
HIGH-TECH Vane Pump PVL23-65-125-F-1R-UU-10
CKD Air Cylinder SRL2-LB-40B-700
SMC Solenoid Valve VF5120-5GB-02
TYCO Relay HFW1131K05M
Eltra Encoder EL58C600S5/28P10X3PR
TCL Air Conditioner KFRd-72LW-DBp-XCA11+B1
Recent related posts
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
06/14/2020
Reciprocating compressor
Reciprocating compressor refrigerators The last one we want to see is reciprocating compressors. As newer and more efficient technologies have replaced it, this type of refrigerator is becoming less and less common, at least in the field of commercial ref 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦 ᮔDž༬皧嫦ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿먲僧ᐱ㥲ᐲ�僬㣢ᐲ ᠾ 랖僧ߜ 識 �僬㣢ᐲ 臆S㥲ᐲ ᬄğ 識 理艏S杴 識杴 㥲ᐲ 琉
-
06/14/2020
Twin screw compressor
Twin screw compressor
-
11/02/2023
What is a Rotary Screw Air Compressor? Everything You Need to Know
Rotary screw air compressor (screw air compressor, screw type air compressor, rotary screw compressor), is a positive displacement air compressor
-
07/05/2022
Installation Of Magnet Pump
1.Dropping or subjecting the pump to strong impact may result failure. Handle the pump with care.
-
08/05/2022
FANUC Spindle Amplifier Alarm Codes and Solutions (2)
The following is a continuation of the previous article, and introduces FANUC spindle drive alarm codes 24-46.
-
09/29/2022
Positive Displacement Pump vs Centrifugal Pump
<strong>Positive displacement pump</strong> refers to the pump that uses the internal volume changes of the pump cylinder to transport liquid
-
02/06/2024
Troubleshooting Guide: Convection Oven Fan Not Spinning
The convection oven, with its innovative fan system, has revolutionized the way we cook, offering even heat distribution and faster cooking times.
-
07/29/2022
What is Hydraulic Motor
Hydraulic motor is an executive component of the hydraulic system, which converts the hydraulic pressure energy provided by the hydraulic pump
-
08/20/2020
What are the protection devices of industrial chillers
Industrial chiller is a kind of water cooling equipment that can provide constant temperature, constant current and constant pressure cooling equipment. The principle of the chiller is to inject a certain amount of water into the internal water tank of th ﰸ2 䀀