Product name | DC Fan |
Frame material | Plastics |
Series | San Ace 92 |
Frame size(mm) | Square - 92mm L x 92mm H |
Frame thickness | 25mm |
Rated voltage[V] | 12VDC |
Rated current[A] | 0.14 |
Rated input[W] | 1.68 W |
Rated speed[min-1] | 2650 |
Max. airflow[m3/min] | 1.26 m3/min |
Max. airflow[CFM] | 44.5 CFM |
Max. static pressure[Pa] | 30.0 Pa |
Max. static pressure[inchH2O] | 0.12 |
SPL[dB(A)] | 27 dB(A) |
Expected life[h] | 40000/60℃ (70000/40℃) |
Sensor type | With a pulse sensor |
IP rating | - |
PWM control function | No |
Bearing Type | - |
Fan Type | - |
Features | - |
RPM | - |
Termination | - |
Operating Temperature | - |
Approval Agency | - |
Weight | - |
Series: SanAce92
Part status: Active
Voltage-Rated: 12VDC
Size/Size: Square-92mmLx92mmH
Width: 25.00mm
airflow:-
Static pressure:-
Bearing type: Ball
Fan type: Tubeaxial
We can also provide the following models
9GA4748A9D013
9GA0505M7D01
9HV0512D30013
9GV1424W30011
9GA1505M60023
9GV0412K9D01
9HV2012B6D011
9WL1748M5HD001
9GA1248H3002
9HV1424S7021
9GV0412H9001
9WP1712G6H002
9HV0924A30013
9HV0312A0021
9GA1705K0D0013
9HV1348W1002
9HV0448D50023
9GA1405D9D01
9WP1248H5HD001
9LG5712P4SD001
9HV1712G1023
9GA3605S502
9GA5712D7D0013
9L0648E802
9WV0412D1H011
9GV1712L7001
9GA1412K2D011
9HV0924E2D001
9HV1512A3011
9GA1324K201
9HV0924M5D0013
9GV2024S20023
9L5748S401
9GV0348A60011
9HV3624S2D011
9GA1524D90011
9B1TJ24P4H002
9GV1348G5021
9L5724J1002
9L1224S1D01
9GA2012K902
9GA0324E501
9GV1712F4021
9GA0805S0013
9WV1748D6H0011
9GV5712A402
9WP5724S50021
9GA1512F10021
9GA1524A9002
9GA2048H701
9GA5748K9D0013
9WV1748H4H021
9GV1348A5001
9GA0405E10021
9HV1448B70021
9HV0524K9023
9HV0848S402
9WP0448L6H021
9L0948M002
9WP0624F6H0011
9HV1424E9D011
9WL0924D4H021
109BF24H016-1
9HV0905K70023
9WV0824D40021
9GA5748G4D001
9HV1548W70011
9HV0805J30023
9GV1212C4021
9TJ24P1HD001
9HV0624S00013
9GA1324E20013
9CRA0512G902
9GA1524S4013
9GV3648D70011
9GA0605F6021
9GV5705E50021
9GV0348M3D0011
9HV4748H5D001
9GA0424G10011
9GV0412L0011
9GA1224B0D001
9GV1712C5023
9LG0812M402
9HV3612F5023
9GV0512L3D011
109BG12SD6-1
9HV5712W4D013
9BC24G012
9HV1705S1001
9WL1212M6D001
For more information,please contact us freely
Sanyo Denki Fan 9S0912F401
People who bought this item also viewed
Ebmpapst Fan A2D250-AJ02-11
Sanyo Denki Fan 9G1212H102
Sanyo Denki Fan 109P4412H8016
Sanyo Denki Fan 109P0412H601
Sanyo Denki Fan 9G0912M2D031
SUNON Fan MEC0251V3-000U-A99
Sanyo Denki Fan 109P0412H3E033
KAKU Fan KA9225HA2SAT
Nidec Fan D04R-24TS2
Sanyo Compressor C-6RVN93H0V
Danfoss Transformer 052F4031
Siemens Contactor 3RT2016-2AH02
Foyo Electric Motor FY86EL402A-14J
MAHLE Filter OX1282D
Danfoss Sight Glass SG6S
Allen-Bradley PLC 1785-ENET C
CRYDOM Relay A2410PG
PANASONIC Capacitor 440V 35UF
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
OBO Surge Protection Device V25-B+C/3+NPE-FS
WAGO Input Output Module 750-421
Contrinex Sensor DW-AS-701-M12
Siemens Transmitter 7MF4433-1DA02-2AC1
AMB VFD Frequency Converter AMB300-355G/400P-T3
Recent related posts
-
08/20/2020
How to judge the fault based on the indicator light of the ice machine
1. The power indicator light keeps flashing quickly and the machine does not work: The cause of the failure: the water temperature probe is open. Repair method: Open the rear cover, open the cover of the electric control box above the compressor, find a three-core connector, check if there is any dropout or poor contact, then reconnect it.
-
08/11/2020
The temperature status and faults of the unit components of various commercial central air-conditioning systems
When the commercial central air-conditioning system is overhauled, temperature inspection and testing are very important, because the unit components of the entire central air-conditioning system have a normal temperature range, beyond which it is an abnormal state.
-
09/02/2020
Why do dry goods 〡 air compressor need staged compression? Can't it be compressed once?
Many people know that two compressor stages are suitable for high pressure production, and one stage is suitable for large gas production. Sometimes, more than two compressions are needed.
-
09/11/2020
Ways to reduce bearing noise
Ways to reduce bearing noise (1) Method of using chemical additives Adding certain chemical additives to the bearing lubricant can reduce bearing noise. For example, a low-noise grease containing noise-reducing additives produced by a factory in Tianjin can reduce bearing noise by 3.9-9.2dB from the original basis. , Suitable for use in miniature or small bearings.
-
11/02/2022
Pros and Cons of 4 Pairs of Electric Motors
According to different structures, working principles, types of operating power, and uses, electric motors can be divided into various types.
-
04/06/2022
Why Does The Fan Keep Running on My Air Conditioner?
Today, the air conditioning, as an electrical appliance that can adjust the temperature and make people feel cool is welcomed and loved by many people.
-
08/28/2020
What are the principles of air compressor frequency conversion How to apply
As we all know, the application of frequency conversion air compressors on the market is becoming more and more extensive.
-
06/14/2022
How to Select a HMI?
There are three basic types of HMIs: the pushbutton replacer, the data handler, and the overseer.
-
09/04/2020
How much do you know about piston compressors
The piston compressor is driven by a motor. The motor drives the crankshaft to make a circular motion through a coupling or gear and belt. The crankshaft drives the connecting rod (changes the direction of the force) for reciprocating swing motion
-
02/09/2023
What is a Blend Door Actuator?
Blend door actuators, also known as Heating, Ventilation, and Air Conditioning (HVAC) actuators, control the position of the vents and the air flowing into the passenger area of the vehicle.